Instructions for use DSEclinical Typ 5198 Table of contents Table of contents 1 User instructions ........................ 6 1.1 User guide ........................6 1.1.1 Abbreviations ..................... 6 1.1.2 Symbols ......................6 1.2 Service ......................... 6 1.3 Warranty terms and conditions..................7 1.4 Transportation and storage.....................
Page 4
5.6.3 Using triple-function handpieces ................58 5.6.4 Using the multifunctional handpiece..............60 5.6.5 Using KaVo Poly One................... 63 5.6.6 Using Satelec mini LED..................64 5.6.7 Using the PiezoLED ..................... 64 5.7 Using the KL702 / KL 703 in ENDO mode (optional accessory) ........... 65 5.7.1...
Page 5
Table of contents 6.3.2 Replace the OXYGENAL 6 bottle ................89 6.3.3 Check the OXYGENAL 6 concentration..............90 7 Safety check according to VDE 0701 / 0702..............92 8 Troubleshooting ......................... 93 9 Tested KaVo accessories ....................96 5 / 100...
CE mark according to Medical Devices Directive EC 93/42 Action required eLabeling ID 1.2 Service KaVo Customer Service: +49 (0) 7351 56-1000 service.einrichtungen@kavokerr.com or service.treatmentunits@kavokerr.com Please refer to the serial number of the product in all inquiries! For further information, please visit: www.kavo.com 6 / 100...
12 months from the date of purchase as confirmed by the sales- person. In case of justified complaints, KaVo will honour its warranty with a free re- placement or repair. The warranty does not cover defects and their consequences that arose or may...
Terms and Conditions, Art. 28). Outside Germany Note KaVo shall not be held liable for damage arising from transportation. The shipment must be checked on arrival. If the packaging is visibly damaged on delivery, please proceed as follows: 1. The recipient of the package must record the loss or damage on the delivery receipt.
Page 9
Instructions for use DSEclinical Typ 5198 1 User instructions | 1.4 Transportation and storage Protect from moisture! Permissible stacking load Temperature range Humidity Air pressure 9 / 100...
Instructions for use DSEclinical Typ 5198 2 Safety | 2.1 Description of safety instructions 2 Safety 2.1 Description of safety instructions 2.1.1 Warning symbol Warning symbol 2.1.2 Structure DANGER The introduction describes the type and source of the hazard. This section describes potential consequences of non-compliance. ▶...
2.2 Safety instructions 2.2.1 General DANGER Explosion hazard. Risk of fatal injury. ▶ Do not use KaVo product in areas subject an explosion hazard. DANGER Electricity Electrical shock ▶ Before opening the unit covers, pull the plug from the mains or disconnect the unit from the voltage source.
The present product is subject to the EC Directive on used electrical and elec- tronic devices and must be disposed within Europe at a special facility. Fur- ther information can be obtained from KaVo or a dental distributor. 12 / 100...
Instructions for use DSEclinical Typ 5198 3 Product description | 3.2 DSEclinical type 5198 3.1.2 Product-specific The KaVoDSEclinical type 5198 is used for the training and vocational training of dentistry students at universities and for advanced dentist training at ad- vanced training institutes, clinics, and universities.
INTRA LUX Motor K 200, KL 702 or KL 703, triple-function or multifunc- tional handpiece, intraoral camera, and PiezoLED. The respective handpieces are automatically detected. The assistant element can be optionally fitted with the KaVo Poly One, Satelec Mini LED or with a second triple-function or multifunctional handpiece. 15 / 100...
Instructions for use DSEclinical Typ 5198 3 Product description | 3.3 Controls CAUTION Rotating instruments and tools Injury hazard ▶ Tie up long hair. ▶ Remove jewellery. ▶ Follow the accident prevention regulations. ▶ Comply with the maximum permissible rotating speed and maximum ap- plication pressure in accordance with the regulations of the device manu- facturer.
Instructions for use DSEclinical Typ 5198 3 Product description | 3.3 Controls 3.3.3 Assistant unit Group of keys for hygiene Group of keys for illumination Group of keys for the timer Group of keys for patient simulator 3.3.4 Triple-function handpieces Triple function handpiece One ①...
Instructions for use DSEclinical Typ 5198 3 Product description | 3.3 Controls Triple-function handpiece ① Air button (A) ② Cannula ③ Gripping sleeve ④ Water button (W) ⑤ Ring blue 3.3.5 Foot control The footswitches of the foot control have two functions. The functions of the footswitches depend on if an instrument is mounted or removed.
Instructions for use DSEclinical Typ 5198 3 Product description | 3.3 Controls 3.3.6 Groups of keys Group of keys for patient simulator Assistant unit key Dentist unit key Designation "Patient simulator up" "AP 0" key (automatic position 0) "Patient simulator down" "SP"...
Page 20
Instructions for use DSEclinical Typ 5198 3 Product description | 3.3 Controls Group of keys for hygiene Designation Control element Tumbler filler Dentist unit and assistant unit Bowl flushing Dentist unit and assistant unit Call bell (help-summon- dentist unit only ing signal) Intensive germ reduction assistant unit only...
Group of keys for menu selection ① Selection keys for menu functions ② Display 3.4 Identification plates The DSEclinical 5198 rating plate is attached to the base below the patient sim- ulator. The rating plates can include the following symbols: Type...
Page 22
Instructions for use DSEclinical Typ 5198 3 Product description | 3.4 Identification plates Marks and labels of triple-function handpieces SN YY-??????? X.XXX.XXXX 3FH-One XXXX YYYY-MM Marks and labels of triple-function handpiece One ① Company logo of the manufacturer ② Can be sterilised at up to 135°C ③...
Instructions for use DSEclinical Typ 5198 3 Product description | 3.5 Technical Specifications 3.5 Technical Specifications Space needs of DSEclinical type 5198 Width approximately 486 mm Depth approximately 250 mm Maximum height 2300 mm Weight Approximately 70 kg Rated voltage Nominal voltage 100 V / 50/60 Hz (country specific)
Page 24
Instructions for use DSEclinical Typ 5198 3 Product description | 3.5 Technical Specifications Water pressure 1.5 ± 0.3 bar; Flow pressure; 4 x manometer Max. static pressure water 2.5 ± 0.3 bar Water flow 80 ± 10 ml/min Air pressure 3.3 ±...
Triple-function or multifunctional hand- depending on model piece Instructions for use Additional equipment for base unitDSEclinical type 5198 Description Material number Assembly kit Hygiene DSEclinical 5198 Mat. no. 3.006.0266 Spray mist extractor Description Material number Secretion hose Mat. no. 0.211.1761 Suction canula Mat.
Page 26
Instructions for use DSEclinical Typ 5198 3 Product description | 3.6 Scope of delivery Saliva ejector Description Material number Saliva ejector hose Mat. no. 02111571 Saliva ejector, flexible Mat. no. 0.236.2128 26 / 100...
4 Commissioning Note The DSEclinical type 5198 dental simulation unit may be installed by trained technical staff only and must be bolted to the floor in accordance with KaVo standards. Comply with the Technician and Installation Instructions for the assembly, set-up and installation.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.1 Operation in general 5 Operation 5.1 Operation in general 5.1.1 Switching the DSEclinical type 5198 on ▶ Turn on main switch④ . ▶ Move dentist unit ①, assistant unit ②, and foot control ③ into treatment po- sition.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.1 Operation in general 5.1.2 Turn off the DSEclinical type 5198 and move it to park position On completion of treatment or training, the patient simulator must be returned to its parked position. ▶...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.2 Positioning the patient simulator 5.2 Positioning the patient simulator CAUTION Adjustment of the patient simulator position is associated with a risk of getting pinched. Various parts of the height adjustment move along when the patient simulator position is adjusted.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.2 Positioning the patient simulator ▶ Grasp the backrest by the headrest and swing it to the right or left. 5.2.2 Adjust head rest Adjust bar length ▶ Push head rest in and out to change bar length. Setting inclination ▶...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.2 Positioning the patient simulator ▶ Turn clamping button to the right to tighten it up again. Removing head cushion The head rest's cushion is detachable. ▶ Loosen the screw. ▶ Pull cushion slightly upwards and then remove it towards the front. 5.2.3 Position the head of the patient simulator The head of the dental patient simulator can perform the following movements: ▪...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.2 Positioning the patient simulator ▶ Loosen the screw on the head of the dental patient simulator. ▶ Then guide the head into the desired position and adjust the head rest ac- cordingly.
Page 34
Instructions for use DSEclinical Typ 5198 5 Operation | 5.2 Positioning the patient simulator Note The memory is erased when you turn off the device. After turning on the device again (for example in the morning or after a lunch break), the patient simulator does not execute a defined movement when you press the "LP"...
Page 35
Instructions for use DSEclinical Typ 5198 5 Operation | 5.2 Positioning the patient simulator Note The automatic position "Most recent position" is saved to the "LP" button. The "LP" button cannot be assigned to another automatic position. Press the "LP" button for the patient simulator to automatically move to the most recent po- sition before the rinsing position.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.2 Positioning the patient simulator Automatic positions can be recalled through two foot-operated buttons; the standard setting is as follows: ▪ "Spray pre-selection" foot-operated button: automatic position "LP" (most recent position) ▪...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.3 Using functions through the MEMOdent menu (optional) Dentist unit/assistant foot control cross- Function unit buttons switch The patient simulator moves upward. The patient simulator moves downward. The backrest moves up- ward.
Page 38
Instructions for use DSEclinical Typ 5198 5 Operation | 5.3 Using functions through the MEMOdent menu (optional) Select function There is a selection button below each display field to select the individual func- tions. The selection buttons are assigned to the respective symbol in the display above.
Page 39
Instructions for use DSEclinical Typ 5198 5 Operation | 5.3 Using functions through the MEMOdent menu (optional) Note The device automatically saves the activation of level switching for the cur- rent dentist. Note Level switching is deactivated using the same key combination as activation. ▶...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.3 Using functions through the MEMOdent menu (optional) ▶ Press the "S2" selection key ① to display status messages. ▶ Press the selection keys "+" ② and "-" ① to switch between multiple status messages.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.3 Using functions through the MEMOdent menu (optional) ▶ Press the "Save" key to save the values. You can save after setting each value, or after setting all values. ð Saving is acknowledged with a tone. Setting the speed (only if level switching is activated) ▶...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.3 Using functions through the MEMOdent menu (optional) ▶ Briefly press "Preselect level" button to select the level. ▶ Press "Preselect level" button for 4 seconds in order to change settings. ð...
Page 43
Instructions for use DSEclinical Typ 5198 5 Operation | 5.3 Using functions through the MEMOdent menu (optional) Setting the intensity (only if level switching is activated) ▶ Press the button for "Decrease value" to decrease the intensity. ▶ Press the button for "Increase value" to increase the intensity. ð...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.3 Using functions through the MEMOdent menu (optional) Turn the light On / Off (PiezoLED only) ▶ Briefly press the "Light" button to switch between "On" and "Off". Symbol Function Light "Off" Light "On"...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.3 Using functions through the MEMOdent menu (optional) ▶ Press the "Save" key to save the values. You can save after setting each value, or after setting all values. ð Saving is acknowledged with a tone. 5.3.7 Use the Timer Select the timer time ▶...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.3 Using functions through the MEMOdent menu (optional) ▶ Press the "Back" button to return to the default (without saving). Adjusting the clock time Set the default with the timer. See also: 2 5.3.7.2 Setting the timer time, Page 45 ▶...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.4 Using function through the dentist or assistant unit Symbol Function from briefly Function from holding pressing the key down the key "Freeze" "Save" Create freeze frame. Save current picture. Go to previous picture. No function Go to next picture.
KaVo KEY Laser III or KEY Laser 3+ can lead to the unintentional activation of the KaVo KEY Laser III and KEY Laser 3+. ▶ When using the KaVo KEY Laser III or the KEY Laser 3+, switch the operat- ing light to laser mode.
Page 49
KaVo DIAGNOdent can lead to faulty measurements. ▶ Switch the operating light to laser mode when using the KaVo DIAGNOdent. ▶ Or switch off the operating light, do not use KaVo DIAGNOdent and operat- ing light KaVoLUX 540 LED simultaneously. CAUTION Premature hardening of composite fillings.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.5 Operating the foot switch ð The operating light is switched on in its most recent active state: operating light on, COMPOsave mode on or dimmed light. ▶ Press the "operating light" button once again. ð...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.5 Operating the foot switch 5.5.2 Special functions of the wireless foot control CAUTION Electrical power Personal injury or damage to the wireless foot control. ▶ Do not touch the contacts of the charger connector! The wireless foot control transmits the user activities to the treatment centre in a wireless manner.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.5 Operating the foot switch Residual capacity Foot control status Status display / Beep charge status display < 10 % Idle state Flashes yellow Two brief beeps when a Foot control is on (approx.
Page 53
Instructions for use DSEclinical Typ 5198 5 Operation | 5.5 Operating the foot switch To establish a connection between the wireless foot control and the treatment unit, the devices need to be synchronised. Synchronisation needs to be per- formed once by a service technician. ▶...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.5 Operating the foot switch Example of the identification of the wireless foot control CAUTION Improper use of the wireless foot control Damage or malfunction ▶ In case of improper use (such as cleaning), turn off the wireless foot control or the treatment unit.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.5 Operating the foot switch 5.5.7 Start and regulate instruments Note The foot pedal is equipped with a middle centring function, i.e., the foot pedal always returns to levels 1 to 3 each time after it is moved to the left or right. CAUTION Centring in the middle is effected for the foot control by a positioning motor.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.5 Operating the foot switch 5.5.9 Actuate blown air ▶ Remove the handpiece (such as turbine, motor) from the holder. ð The handpiece is active. ▶ Press the "Blown air" foot button. ð...
Instructions for use DSEclinical Typ 5198 5 Operation | 5.6 Using instruments Note Charge the wireless foot control with the charger supplied by KaVo only. Note The wireless foot control charger may only be used indoors and must be pro- tected from moisture.
Injury from swallowing the cannula. ▶ Before each treatment, ensure that the cannula is properly locked or screwed into place and firmly seated. ▶ Use original KaVo cannulas only. CAUTION Risk of injury from touching the cheek with the handpiece.
Page 59
Instructions for use DSEclinical Typ 5198 5 Operation | 5.6 Using instruments Triple function handpiece One ① Cannula ② Water button (green ring) ③ Air button (blue ring) ④ Handpiece and hose Triple-function handpiece ① Air button (A) ② Cannula ③...
Danger of injury from cannulas that are worn or not locked into place. ▶ Before each treatment, ensure that the cannula is locked into place and firmly seated. ▶ Use original KaVo cannulas only. Note Cannulas can be rotated by 360 The "on"...
Page 61
Instructions for use DSEclinical Typ 5198 5 Operation | 5.6 Using instruments ▶ Remove the turbine from the holder. ▶ Adjusting the air/water heating. See also: 2 Changing the multi-function syringe settings in the MEMOdent menu, Page ▶ Check the passage for the media in the cannula ② each time before using it on a patient.
Page 62
Instructions for use DSEclinical Typ 5198 5 Operation | 5.6 Using instruments Adjustable, as an option: ▶ Take the instrument from the holder. ð This activates the cold light. ▶ Only if the instrument is connected to the dentist unit, take the instrument from the holder and press the foot pedal.
To ensure proper function, the poles need to be in- serted correctly. ▶ Push the holder ③ forward and pull the defective KaVo MULTI LED lamp ② out of the socket. ▶ Insert new Kavo MULTI LED lamp (Mat. no. 1.007.5372).
Instructions for use DSEclinical Typ 5198 5 Operation | 5.6 Using instruments 5.6.6 Using Satelec mini LED Warning Danger from optical radiation. Eyes can be blinded or damaged by LED of risk group 2 in accordance with IEC 62471 (blue light). ▶...
Incorrect transmission ratio. Damage from incorrect speed / incorrect torque. ▶ Only use KaVo 1:1 reducing shanks 20LH or 20LP or MASTERmatic LUX M20 L with 1:1 INTRA LUX head L68 B (Mat. no. 1.008.1834) or 3:1 IN- TRA head L66 B (Mat. no. 1.008.1831).
Instructions for use DSEclinical Typ 5198 5 Operation | 5.7 Using the KL702 / KL 703 in ENDO mode (optional accessory) CAUTION Excessive torque. Injury or damage to instruments. ▶ Use root canal instruments in ENDO mode only. Technical specifications for the KL 703 LED / KL 702 in ENDO mode Note The technical specifications apply to the KL 703 LED / KL 702 in ENDO mode.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.7 Using the KL702 / KL 703 in ENDO mode (optional accessory) Parameters in the display ① Direction of motor rotation ② Torque mode ③ Transmission factor ④ ENDO Mode ⑤ Speed ⑥...
Page 68
Instructions for use DSEclinical Typ 5198 5 Operation | 5.7 Using the KL702 / KL 703 in ENDO mode (optional accessory) The following parameters can be changed: ▪ Speed ▪ Torque ▪ Torque mode Select the parameter memory ▶ Press "Programme" button in order to call-up the desired parameter memory location (P1 to P6).
Page 69
Instructions for use DSEclinical Typ 5198 5 Operation | 5.7 Using the KL702 / KL 703 in ENDO mode (optional accessory) Save the parameters in programs 1 to 6 using the "Program" key (press for 2 seconds). You can save after setting one parameter, or after setting all para- meters.
Page 70
Instructions for use DSEclinical Typ 5198 5 Operation | 5.7 Using the KL702 / KL 703 in ENDO mode (optional accessory) ð The motor starts by rotating clockwise (if not selected otherwise). The torque is limited to the set threshold. The speed reduces until it stops de- pending on the load.
Instructions for use DSEclinical Typ 5198 5 Operation | 5.8 Converting the DSEclinical type 5198 for right- or left-handed users ▶ Press the foot pedal. ð The motor starts by rotating clockwise (if not selected otherwise). 5.7.5 Leaving ENDO Mode ▶...
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.1 Maintenance 6 Service and Care 6.1 Maintenance Note Repair and servicing work on the electrical part of the unit may be done only by skilled staff or by staff trained in the factory. During servicing work pull the mains plug out of the socket or disconnect the unit from the mains.
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.2 Care ð The suction motor starts automatically when the suction tubes are removed from the holder. ▶ Hold the cloth under the sieve holder, and pull the sieve insert out of the housing.
Note Wet the O-rings of the gripping sleeves after sterilisation using silicone grease (Mat. no. 1.000.6403) or KaVo Rota Spray 2 (Mat. no. 0.411.7510). After replacing the cannula, the air channel must be blown out before the start of treatment to ensure that the air exiting during treatment is dry.
Page 75
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.2 Care Cleaning the triple-function and multifunctional handpiece Automatic cleaning Not applicable. NOTICE Damage caused by improper cleaning/disinfection. ▶ Do not wash the gripping sleeve and the cannula in the washer disinfector. ▶...
Page 76
Requirement The multifunctional handpiece has been reprocessed. ▶ Apply KaVo silicone grease (Mat. no. 1.000.6403) or KaVo Rota Spray 2 (Mat. no. 0.411.7510) to the O-rings of the joint between the gripping sleeve and cannula. Use cotton buds for this purpose.
Page 77
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.2 Care Sterilising the 3-function and multifunction handpiece Note The grip sleeve and cannula can be sterilised. ▶ Hold the 3-way or multifunctional handpiece at the gripping sleeve and take off the cannula with a slight twisting motion.
KaVo OXYGENAL 6. Rinsing programme and intensive germ reduction facilitate the rinsing and germ reduction of the water-supplying system. This counteracts the formation of mi- cro-organisms at times of stagnation and ensures a hygienic water supply.
Page 79
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.2 Care Preparation for rinsing programme and intensive germ reduction Placing the handpieces in the hygiene centre ▶ Open the door of the hygiene centre. The cannulas of the three-function and multifunctional handpieces must be re- moved for the cleaning programmes.
Page 80
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.2 Care Placing the COMFORTbase in the hygiene centre Note A seat adapter for the germ reduction attachment is available for the COM- FORTbase. ▶ For the cleaning programmes, press the seat adapter into one of the six holders of the hygiene centre.
Page 81
During intensive germ reduc- tion, the afferent water ducts are automatically filled with a higher concentra- tion of KaVo OXYGENAL 6. The intensive germ reduction program lasts ca. 45 minutes. The increased hydrogen peroxide concentration acts in the system for at least 30 minutes.
Page 82
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.2 Care Intensive germ reduction must be carried out: ▪ At initial start-up ▪ Before, during and after prolonged downtimes (more than 4 weeks) ▪ Over the weekend ▪ During vacations Start intensive germ reduction ▶...
Page 83
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.2 Care ▶ Place all instruments in the hygiene centre and close the flap of the hygiene centre. Interrupt intensive germ reduction during the dwell time So that no one will have to remain with the device throughout the entire intens- ive germ reduction process, intensive germ reduction can be interrupted in pro- gram step 4 (e.g.
The unit is now ready for use. Additional intensive germ reduction during period of non-use KaVo recommends carrying out an additional intensive germ reduction at uni- versities during semester breaks. This flushes the parts of the unit and replaces the germ reduction liquid.
Page 85
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.2 Care Preparation Requirement Suction hoses remain hanging in the holder. ▶ Press the "HYDROclean" button. ð The HYDROclean function is in the preparatory stage. The upper LED flashes rapidly. Start the HYDROclean function ▶...
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.2 Care ▶ Press the "HYDROclean" button. ð The HYDROclean function is in the preparatory stage. The top display LED of the button flashes quickly. ▶ Plug the suction hoses without connectors onto the hygiene centre. ▶...
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.3 Replacing and checking disinfection and germ reduction agents ▶ Clean the handpiece holder under running water and insert it. The handpiece holder can be disinfected in a washer disinfector unit. ▶...
Page 88
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.3 Replacing and checking disinfection and germ reduction agents ▶ Open the germ reduction cabinet. ▶ Unscrew the lid of the new DEKASEPTOL Gel bottle. ▶ Take the empty bottle out of the germ reduction cabinet, unscrew the con- nector of the DEKASEPTOL Gel bottle and screw it onto the new bottle of DEKASEPTOL Gel and then insert the bottle.
6.3.2 Replace the OXYGENAL 6 bottle Note Replenish KaVo OXYGENAL 6 only if the acoustic signal is issued every 10 seconds. The signal can be turned off as follows: Hold down the control pedal, and move the backrest up and down. The next time the treatment centre is turned on, the acoustic signal is issued again.
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.3 Replacing and checking disinfection and germ reduction agents 6.3.3 Check the OXYGENAL 6 concentration ▶ Test the standard concentration 0.02% H (200ppm): Fill a measuring cup (40 ml) with 39 ml water and 1 ml treated water. ▶...
Page 91
Instructions for use DSEclinical Typ 5198 6 Service and Care | 6.3 Replacing and checking disinfection and germ reduction agents ð Compare the colours and read the value: 5 mg/l is shown for a concentra- tion of 200ppm. Other concentrations can be tested using the following table: H2O2 concentration Measuring cup Ratio water : treated...
▪ the applicable accident prevention regulations. The overarching guidelines and/or national laws, national regulations and the rules of technology applicable to this product for start-up and use of the KaVo product for the intended purpose are to be applied and complied with.
Turbine making loud Turbine wheel faulty. ▶ Follow turbine instructions. running noises. Satelec Mini LED / Also refer to: Instruc- KaVo Poly One does not tions for Use of the work. Satelec Mini LED / KaVo Poly One 93 / 100...
Page 94
Instructions for use DSEclinical Typ 5198 8 Troubleshooting Malfunction Cause Remedy ▶ Notify a service technician. Spray at instruments Water pressure or air works poorly. pressure are set incor- rectly. ▶ Clean spray nozzles in accordance with the en- Calcified/dirty spray closed instrument instructions.
Page 95
Instructions for use DSEclinical Typ 5198 8 Troubleshooting Malfunction Cause Remedy ▶ Carry out an intensive germ reduction. Display shows: ID 69 An intensive germ re- duction must be done. See also: 2 Intensive germ reduction ▶ Insert the DEKASEPTOL bottle. Display shows: ID 72 Dekaseptol bottle.
Instructions for use DSEclinical Typ 5198 9 Tested KaVo accessories 9 Tested KaVo accessories The accessories listed below are optional and can be supplied depending on unit model. BS = kit Device Figure Name Material number Operating light depending on model...
Page 97
Instructions for use DSEclinical Typ 5198 9 Tested KaVo accessories Assistant unit Figure Description Material number Satelec Mini LED Mat. no. 1.003.8114 KaVo Poly One Mat. no. 1.009.7779 Triple function handpiece Mat. no. 1.009.7774 Assembly kit second depending on model...
Need help?
Do you have a question about the DSEclinical 5198 and is the answer not in the manual?
Questions and answers