General ............................. 13 3.1.2 Product-specific ........................13 3.2 Scope of delivery ........................... 14 3.3 Overview of DSE Expert ........................15 3.4 Dentist and assistant unit........................15 3.5 Control element ............................. 17 3.6 Triple-function handpieces........................18 3.7 Foot control A ............................19 3.8 Foot control C ............................
Page 4
Instructions for use DSE Expert Table of contents 5.1 Operation in general ..........................32 5.1.1 Switching the patient simulator on .................... 32 5.1.2 Moving the dentist element and assistant element into treatment position....... 32 5.1.3 Moving the patient simulator into the treatment position ............33 5.1.4...
For further information, please visit: www.kavo.com 1.3 Warranty terms and conditions Within the scope of the applicable KaVo delivery and payment conditions, KaVo guar- antees proper function, absence of defects in material and workmanship for a period of 12 months from the date of purchase as confirmed by the salesperson.
Instructions for use DSE Expert 1 User instructions | 1.4 Transportation and storage In case of justified complaints, KaVo will honour its warranty with a free replacement or repair. The warranty does not cover defects and their consequences that arose or may have...
Art. 28). Outside Germany Note KaVo shall not be held liable for damage arising from transportation. The shipment must be checked on arrival. If the packaging is visibly damaged on delivery, please proceed as follows: 1. The recipient of the package must record the loss or damage on the delivery re- ceipt.
Page 8
Instructions for use DSE Expert 1 User instructions | 1.4 Transportation and storage Humidity Air pressure 8 / 74...
2.2.1 General information DANGER Explosion hazard. Risk of fatal injury. ▶ Do not use KaVo product in areas subject an explosion hazard. DANGER Electricity Electrical shock ▶ Before opening the unit covers, pull the plug from the mains or disconnect the unit from the voltage source.
Page 10
Instructions for use DSE Expert 2 Safety | 2.2 Safety Instructions DANGER Electrical power. Electrical shock ▶ If the light is attached, pull the mains plug of the unit and of the light or disconnect all poles of the unit from the voltage source.
Instructions for use DSE Expert 2 Safety | 2.2 Safety Instructions 2.2.2 Product-specific CAUTION Danger if unit not in proper working order or not being used properly. Risk of injury and danger to material and unit. ▶ Use only suitable tools.
According to EC directive 2012/19 concerning waste electrical and electronic equip- ment, this product is subject to the cited directive and must be disposed of accord- ingly within Europe. For more information, please visit www.kavo.com or contact your specialised dental supplier. For final disposal:...
If you have any questions regarding proper disposal of the KaVo product, please contact the KaVo branch. The use of this KaVo product is not permitted in areas subject to an explosion hazard. The following persons are authorised to conduct repairs and servicing and the safety check on the KaVo product: ▪...
Instructions for use DSE Expert 3 Description of the product | 3.2 Scope of delivery 3.2 Scope of delivery DSE Expert scope of delivery depends on version and accessories ▪ Basic device DSE Expert ▪ DPS Positioning DSE Expert ▪ EBS Doors (lock: Symo) installation kit ▪...
Instructions for use DSE Expert 3 Description of the product | 3.3 Overview of DSE Expert 3.3 Overview of DSE Expert ① LED operating light, optional (Halux ② Assistant element, optional LED 20-3 P FX Mat. no. 1.011.8846 or HX LED 7 P FX Mat. no. 1.011.8847) ③...
Page 16
Instructions for use DSE Expert 3 Description of the product | 3.4 Dentist and assistant unit ① Syringe DCI 3439, triple-function hand- ② Saliva ejector piece 3F One, 3F, MF-LUX handpiece angled, optional ③ Spray mist sucker ④ Satelec Mini LED/Poly One (optional) ⑤...
Instructions for use DSE Expert 3 Description of the product | 3.5 Control element 3.5 Control element ① Counter-clockwise rotation display ② Spray display ③ Instrument pre-selection laboratory ④ Chassis brake handpiece ⑤ Display ⑥ Timer ⑦ Bell (optional) ⑧ Additional motor drives (optional) ⑨...
Instructions for use DSE Expert 3 Description of the product | 3.6 Triple-function handpieces 3.6 Triple-function handpieces Triple function handpiece One ① Cannula ② Water button (green ring) ③ Air button (blue ring) ④ Handpiece and hose Triple-function handpiece ① Air button (A) ②...
Instructions for use DSE Expert 3 Description of the product | 3.7 Foot control A Syringe DCI 3439 ① Cannula ② Water button ③ Air button 3.7 Foot control A ① Foot pedal start/stop ② Spray button ③ Cross switch clockwise/counter-clock- ④...
Instructions for use DSE Expert 3 Description of the product | 3.9 LED lights (optional) 3.9 LED lights (optional) Halux LED 20-3 P FX HX LED 7 P FX ① Joint ② Function keys, see separate instruc- tions for use of the operating light ③...
Instructions for use DSE Expert 3 Description of the product | 3.10 Rating plates 3.10 Rating plates The rating plate is attached on the back panel of the unit and includes the following symbols: Device type DSE Expert Expert Serial number Material number e.g.
Page 22
Instructions for use DSE Expert 3 Description of the product | 3.10 Rating plates Marks and labels of triple-function handpieces SN YY-??????? X.XXX.XXXX 3FH-One XXXX YYYY-MM Marks and labels of triple-function handpiece One ① Company logo of the manufacturer ② Can be sterilised at up to 135°C ③...
Instructions for use DSE Expert 3 Description of the product | 3.11 Technical Specifications 3.11 Technical Specifications Recommended space needs of the DSE Expert (single-user) Width 1200 mm Depth 1800 mm Height including LED simulation light 1880 mm Dimensions in park position Height 700 mm...
Page 24
Instructions for use DSE Expert 3 Description of the product | 3.11 Technical Specifications Triple function handpiece Water pressure 1.5 ± 0.3 bar; Flow pressure; 4 x mano- meter Max. static pressure water 2.5 ± 0.3 bar Water flow 80 ± 10 ml/min Air pressure 3.3 ±...
Page 25
Handpieces depending on type of unit KL motor 40,000 min Dental drives 30,000 min K4 handpiece 4914 / K5 plus handpiece 4911 DSE Expert speed in Endo mode Range 100 to 40 000 min (rpm) Max. clockwise speed 40 000 min (rpm) Max.
Instructions for use DSE Expert 4 First use | 4.1 Fitting and connecting 4 First use 4.1 Fitting and connecting 4.1.1 Connect power, air and water DANGER Electrical power. Electrical shock ▶ If the light is attached, pull the mains plug of the unit and of the light or disconnect all poles of the unit from the voltage source.
Instructions for use DSE Expert 4 First use | 4.1 Fitting and connecting Requirement The air to be used for the dental simulation unit must be dry, oil-free, non-contamin- ated, and free of pollution. Use a compressor with a dry air system if required.
Instructions for use DSE Expert 4 First use | 4.1 Fitting and connecting Install triple function handpiece ▶ Place the rubber pad ② and instrument hose ① onto the three-function handpiece ③ and screw them tight. 4.1.3 Connect the instruments...
Instructions for use DSE Expert 4 First use | 4.2 Positioning and converting the patient simulator ▶ Install the light in the base and connected to the customer-provided mains voltage connector (see IfU of the light). Comply with the safety notes and instructions on ambient and operating conditions in the IfU of the light.
Page 30
Instructions for use DSE Expert 4 First use | 4.2 Positioning and converting the patient simulator Set the height and inclination of the patient simulator CAUTION Injuries by patient simulator. Contusion or shearing by the motorised motion of the patient simulator.
Instructions for use DSE Expert 4 First use | 4.2 Positioning and converting the patient simulator 4.2.2 Position the head of the patient simulator The head of the dental patient simulator can perform the following movements: ▪ approx. 25 forward nodding movement ▪...
Instructions for use DSE Expert 5 Operation | 5.1 Operation in general 5 Operation 5.1 Operation in general 5.1.1 Switching the patient simulator on ▶ Use the main switch to switch the patient simulator on. 5.1.2 Moving the dentist element and assistant element into treatment position ▶...
Instructions for use DSE Expert 5 Operation | 5.1 Operation in general ð The dentist and assistant element then remains at the adjusted height. 5.1.3 Moving the patient simulator into the treatment position CAUTION Injuries by patient simulator. Contusion or shearing by the motorised motion of the patient simulator.
Instructions for use DSE Expert 5 Operation | 5.1 Operation in general Store the treatment positions A total of 3 treatment positions can be stored on the buttons, Automatic position 0,1,2. ▶ Move the patient simulator to the desired position and then press the correspond- ing Automatic position button until an acoustic signal is emitted.
Instructions for use DSE Expert 5 Operation | 5.1 Operation in general 5.1.5 Safety shut-down To prevent collisions during movements of the patient simulator, a safety shutoff ① is installed on the upper front of the unit to protect people from injury. When the safety shutoff ①...
Instructions for use DSE Expert 5 Operation | 5.2 Foot control A ð This opens the menu for learning the end-positions. exit lmit ▶ Press the S3 (Irn lmit) button in order to start the learning program. ð The learning program moves the patient simulator and quits with a signal sound and the message disappearing.
Instructions for use DSE Expert 5 Operation | 5.3 Foot control C Turn on the spray water ▶ Press the Spray button. ð The spray air is turned on. ▶ Press the Spray button again. ð The spray water is turned on.
Instructions for use DSE Expert 5 Operation | 5.4 Control element 5.4 Control element 5.4.1 Configuration of the preselection buttons Buttons ①, ②, ③, ④, ⑥, ⑧, ⑨, ⑩ are programmed according to the factory settings as per the delivered configuration. The Automatic position buttons ⑪, ⑯ and ⑰ can be programmed to correspond to a certain treatment position.
Instructions for use DSE Expert 5 Operation | 5.5 Instruments 5.5 Instruments 5.5.1 Using the spray mist suction device and saliva ejector Note If the saliva ejector is used, the slide of the spray mist extraction device must be closed.
▶ When the treatment is completed, switch off the main switch of the unit. 5.5.5 Using KaVo Poly One See also: 2 Instructions for use KaVo Poly One 5.5.6 Using the PIEZOsoft/PiezoLED ultrasound scaler Note The setting of the mode is only available in combination with a PiezoLED Ultrasonic Scaler.
5.5.7 K5 plus handpiece 4911 See also: 2 Instructions for use K5 plus handpiece 4911 Note The KaVo K5plus handpiece can be used without an additional controller on the DSE Expert simulation unit (with preparation for laboratory motor). 41 / 74...
Page 42
Instructions for use DSE Expert 5 Operation | 5.5 Instruments ▶ Always place the handpiece ① on the handpiece holder ②. When running the cable to the handpiece holder, make sure that the cable does not run through the area of movement.
Instructions for use DSE Expert 5 Operation | 5.5 Instruments 5.5.8 Using triple-function handpieces Syringe DCI 3439 ① Cannula ② Water button ③ Air button Triple function handpiece One ① Cannula ② Water button (green ring) ③ Air button (blue ring) ④...
Page 44
Instructions for use DSE Expert 5 Operation | 5.5 Instruments Triple-function handpiece ① Air button (A) ② Cannula ③ Gripping sleeve ④ Water button (W) ⑤ Ring blue Note The cannulas can be rotated 360 ▶ Remove the turbine from the holder.
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu 5.5.9 Using the camera See also: 2 Instructions for Use ERGOcam One 5.6 Using functions through the menu 5.6.1 General menu navigation The functions in the menu are used through the selections keys (S1 to S4) on the dis- play ①...
Page 46
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu ① Selection keys (S1 to S4) for menu ② Display functions ▶ Press the "Next" key (S4) to start-up the user menu. ð The user menu displays options and parameters that can be set and changed by the user.
Page 47
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu Option 3: Setting the ENDO holder ▶ Press the "increase value" or "reduce value" keys to set the selected holder. Option 4: Setting the time of day ▶...
Page 48
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu Option 5: Setting the date ▶ Press the "SET" (S2) key to change the values of day, month, and year. ð The value to be changed flashes.
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu Option 7: Setting the display contrast ▶ Press the "reduce value" or "increase value" key to set the contrast of the LCD display. Option 8: Setting the menu language ▶...
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu ▶ Press the "Next" key (S4) to start-up the user menu. Service and error messages in the stand-by menu Service and error messages are displayed in the stand-by menu through the "!" sym- bol.
Page 51
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu Start-up ENDO menu ▶ The ENDO menu is started-up through: • Taking the ENDO motor out of the dentist element (setting in user menu, option • activating the (M) "Additional motor drives" key afterwards...
Page 52
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu Settings Saves the parameters. Selects the ENDO menu. Changes the value. Changes the value. Moves the flashing cursor: Torque mode, speed, torque, torque mode, ... (ring counter).
Page 53
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu Settings Saves the parameters Selects the ENDO menu Changes the speed Range: 100 rpm to 500 rpm: in 10 rpm increments Range: 500 rpm to 1,000 rpm: in 50 rpm increments...
Page 54
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu Option 1: Transmission ratio ▶ Press the "S2" or "S3" key to set the transmission factor. Settings Saves the option Selects the ENDO menu Changes the transmission factor...
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu Settings Changes the torque setting display Unit: % or Ncm Transmission ratio 1:1: 100% = 2.5 Ncm Transmission ratio 3:1: 100% = 8.0 Ncm Selects the next option Option 3: AutoRev.
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu ▶ Press the "S1", "S2", "S3" key to select user 1, 2, and 3, respectively. ▶ Press the "S4" button to call up the second level.
Page 57
Instructions for use DSE Expert 5 Operation | 5.6 Using functions through the menu Setting Actuation Display Spray status Foot control, control keys LED control keys Adjusting the motor ▶ Settings can be changed using the corresponding keys on the control panel or on the foot control.
Instructions for use DSE Expert 6 Service and Care | 6.1 Servicing 6 Service and Care 6.1 Servicing DANGER Electrical power. Electrical shock ▶ If the light is attached, pull the mains plug of the unit and of the light or disconnect all poles of the unit from the voltage source.
Instructions for use DSE Expert 6 Service and Care | 6.1 Servicing 6.1.2 Fill the pressurised water system (if available) CAUTION The pressure tank is heat-sensitive. Material fatigue. ▶ Do not rinse the pressure tank in the dish washer or with hot water (above 50...
Too much or too little Oxygenal 6. ▶ The bottle must always be empty before adding Oxygenal 6. The DSE Expert can be operated optionally with a permanent germ reduction and an intensive germ reduction. This is made possible by dosing KaVo OXYGENAL 6 into the pressure tank.
Page 61
During intensive germ reduction, the affer- ent water ducts are filled with a higher concentration of KaVo OXYGENAL 6. An additional intensive germ reduction must be carried out during extended periods on non-use (from 4 weeks).
Page 62
Instructions for use DSE Expert 6 Service and Care | 6.1 Servicing Intensive germ reduction procedure in the presence of central water supply with Aseptosys valve and pressure tank Note The instruments can be rinsed either with or without the handpieces and cannula.
Page 63
▶ Remove the protective hose from the tube of the KaVo OXYGENAL 6 dosing facil- ity. ▶ Guide the tube through the orifice of the coarse sieve of the KaVo OXYGENAL 6 bottle. ▶ Screw the KaVo OXYGENAL 6 dosing facility tightly to the KaVo OXYGENAL 6 bottle.
Page 64
Instructions for use DSE Expert 6 Service and Care | 6.1 Servicing Check the OXYGENAL 6 concentration ▶ Test the standard concentration 0.02% H (200ppm): Fill a measuring cup (40 ml) with 39 ml water and 1 ml treated water.
Instructions for use DSE Expert 6 Service and Care | 6.2 Care ð Compare the colours and read the value: 5 mg/l is shown for a concentration of 200ppm. Other concentrations can be tested using the following table: H2O2 concentration...
Page 66
Instructions for use DSE Expert 6 Service and Care | 6.2 Care See also: 2 Instructions for Use of the respective handpiece or motor See also: 2 IfU of the operating light 66 / 74...
▪ the applicable accident prevention regulations. The overarching guidelines and/or national laws, national regulations and the rules of technology applicable to this product for start-up and use of the KaVo product for the intended purpose are to be applied and complied with.
Instructions for use DSE Expert 8 Troubleshooting 8 Troubleshooting Malfunction Cause Remedy ▶ Check the safety shut-off and eliminate the reason Patient simulator does not The safety shutoff is activ- for the shut-off. move. ated. Start program for learning the end-positions.
Page 69
Instructions for use DSE Expert 8 Troubleshooting Malfunction Cause Remedy ▶ Preselect cold light. No cold light on the hand- Cold light not preselected. pieces. ▶ Replace the high-pressure lamp or Multi LED. also The high-pressure lamp or refer to: Instructions for Use of the handpiece Multi LED on the hand- piece is defective.
Instructions for use DSE Expert 9 Accessories 9 Accessories The accessories listed below are optional and can be supplied depending on unit model. BS = kit Figure Description Material number INTRA LUX motor KL 701 Mat. no. 1.001.8776 Mat. no. 1.007.0150...
Page 71
Instructions for use DSE Expert 9 Accessories Figure Description Material number BS Foot control DCI as- Mat. no. 1.011.8777 sembly kit BS LED Simulation light as- Mat. no. 1.011.8778 sembly kit BS Assistant element as- Mat. no. 1.011.8779 sembly kit BS DCI syringe assembly Mat.
Page 72
Instructions for use DSE Expert 9 Accessories Picture Description Material number Standard Mat. no. 0.622.3882 Latex Mat. no. 0.622.4872 with drain Mat. no. 0.622.0531 Mat. no. 0.622.1431 with drain and adapter 72 / 74...