12
Brightness adjustment
(PAL)
13
Unicolor adjustment
(PAL)
14
Colour level adjustment
(PAL)
15
Tint adjustment
(PAL)
1. Input the standard colour bar signal
of PAL into AV1.
2. Connect oscilloscope to TP821
(IC803, pin7, G output).
1. Input the standard colour bar signal
of PAL into AV1.
2. Connect oscilloscope to TP821
(IC803, pin7 , G output ).
1. Input the standard colour bar signal
(the same pattern as that of E-12CH)
of PAL into AV1.
2. Connect the oscilloscope to TP820
(B output).
1. Input the standard colour bar signal
(the same pattern as that of E-12CH)
of PAL into AV1.
2. Connect the oscilloscope to TP820
(B output).
13
1. Adjust PAL BRIGHTNESS, and
adjust the black level of G output
so as to get DC 1.5±0.05V.
1. Adjust PAL UNICOLOR, and adjust
so as to get 100% white-black level
video component equal to 2.3±0.05
Vp-p.
Adjust PAL SCOLOR so as to get the
colour bar signal blue amplitude
(black level - peak level) equal to 2.0V
±0.05Vp-p.
1. Adjust PAL TINT so as to get the
colour bar signal magenta amplitude
(black level-peak level) equal to 1.7V
±0.05Vp-p.
LC-121M2E