PHYSICAL INSTALLATION
• The 7067 IntelliTap-II is mounted inside the AES Subscriber Unit.
Figure 1: Installation into 7744 and 7788 Series
PHYSICAL INSTALLATION of 7067 in an AES Subscriber Unit
The Tap is installed inside the subscriber unit.
For 7744, 7788 or 7750-F Subscriber Unit: See Figure 1
• Remove four (4) lower nuts holding main board inside box. Save the nuts.
• Install 4 standoffs (provided) in place of nuts, securing the subscriber unit
circuit board and providing a mount for the "TAP". Do not overtighten.
• Mount TAP board on standoffs. Secure the board with the 4 nuts removed
earlier.
• Earth ground to be connected to right center mounting screw identified with
a green hex nut.
• Install 6 wire modular cord between Tap and subscriber main board.
NOTE: The 7067 IntelliTap-II must be mounted inside the subscriber's
enclosure. Control Panel dry contact available relays for Alarm,
Trouble, Supervision and Delayed Trouble, shall be connected to
Subscriber zone inputs using the AES EOL resistors. The use of
subscriber zone inputs are required for fire alarm and UL installations
as the 7067 IntelliTap is Listed for supplemental alarm reporting only.

SPECIFICATIONS

I/O - Connections:
• J1 – RS-232 data link to AES Subscriber Board, Not Supervised
• J7 – Telephone Line, Alarm Panel Dialer and House Phone Connection
Terminal Block, Not Supervised. Wire size 14-22 Gauge
Indicators:
• D10 – Green LED, Illuminated steady when phone line relay is engaged
• D1 – Red LED - Status , Blink = Normal; Steady = Error
Not illuminated when receiving call, then blinks during data transfer
Switches:
• S1 – Reset Switch, restarts IntelliTap Program
• JP1 – Programming Jumpers, 10 positions
Formats Supported
• Contact ID / Point ID
• 3+1, 4+1, 4+2
AES CORPORATION
285 Newbury Street • Peabody, Massachusetts 01960 USA
Tel (978) 535-7310 • Fax (978) 535-7313
www.aes-intellinet.com
AES Corporation
© 2003-2009 AES Corporation • All Rights Reserved. Rev E
AES•IntelliNet Model 7067 IntelliTap-II
OVERVIEW
The AES Model 7067 IntelliTap-II (also referred to as TAP) is a supplemental
alarm reporting interface for an AES Subscriber Unit. The Tap II can control an
attached incoming telephone line, and provides phone line simulation for
maximum alarm panel compatibility. A 7067 retrieves panel data in Contact
ID or 4+2 formats from the built-in communicator of an alarm panel. The TAP
imitates a digital receiver and gives the proper responses to the alarm panel.
The alarm panel only has to tone dial a selected phone number for the TAP to
respond and receive the event. The TAP forwards the dialer data to the central
station through an AES•IntelliNet Radio Data Network. The IntelliTap II is UL
listed as a supplemental reporting device only.
More Features
• Use with or without a phone line attached.
• Telephone Line Cut Detection: The TAP can monitor for telephone line cuts.
In the event of a line cut or connection without a phone line, the Tap will
simulate line voltage and dial tone so that the panel can convey alarm data to
the AES subscriber unit in the event of an alarm.
• Alternate Reporting Trigger - The Tap has an Err relay output to annunciate
if the radio subscriber unit is off the network. Err output not approved for us in
UL or Fire Alarm installations.
COMPATIBILITY
Alarm Panel Compatibility: The TAP works with an alarm panel's digital
communicator or dialer output that is programmable for either 3+1, 4+1, 4+2,
Contact ID or Point ID formats, with tone dialing capability. In a line cut
situation, the Subscriber ID number is used in the Line Cut Message rather
than the account number assigned in the Alarm Panel's dialer programming.
Radio Subscriber Unit Compatibility: The TAP is an accessory for the AES
IntelliTap ready Radio Subscriber Units. This includes models 7744F and
7788F. Contact AES for compatibility of your Subscriber.
Central Receiver Compatibility: The MultiNet 7705i receiver is compatible
with messages created by the addition of an IntelliTap to an alarm panel. In
addition for backward compatibility, the 7701 with Net77 software, 7703, and
Keltron RF7300 receivers will accept IntelliTap packets. Also for backward
compatibility, some earlier model receivers may require an upgrade. Contact
AES for compatibility of your receiver. Note that the receiver's automation
output sends dialer information from the alarm panel, including the alarm
panel ID number. In a line cut the Subscriber ID number is used.
Note: The automation output will send Contact ID information from the alarm
panel, including the panel ID number. The AES Subscriber Unit's ID is used
in a line cut message detected by the TAP.
Mounting: • Inside subscriber enclosure on provided standoffs
Size: • 5.0" X 3.75" (12.7 X 9.5cm)
Environment:
• Indoor – Dry locations
• Operating Temperature Range: 0° to 49° C (32° to 120°F)
• Storage Temperature Range: -10° to 60° C (14° to 140°F)
• Relative Humidity Range: 0 to 85% RHC, Non Condensing
Power Requirements:
• Voltage – 12 Volts DC nominal
• Current – 50mA
Battery Backup: • Provided and supervised by AES Subscriber Unit
• The TAP shall be installed in accordance with NFPA 72, NEC,
UL 864 and all applicable local codes
WARNING: Test this system periodically for proper operation. AES
assumes no responsibility for this equipment's failure to operate. AES's
sole responsibility is to repair or replace any AES device found to be
defective during the warranty period.
Page 1 of 4
Doc# 40-7067, 6/9/09

Advertisement

loading

Summary of Contents for AES IntelliNet 7067 IntelliTap-II

  • Page 1: Specifications

    The AES Model 7067 IntelliTap-II (also referred to as TAP) is a supplemental • The 7067 IntelliTap-II is mounted inside the AES Subscriber Unit. alarm reporting interface for an AES Subscriber Unit. The Tap II can control an attached incoming telephone line, and provides phone line simulation for maximum alarm panel compatibility.
  • Page 2 Contact ID format for 3+1,4+1,4+2 Format, 1400 Hz handshake the AES-IntelliTap, it is strongly recommended that you use the Ademco Contact ID Format first, then 4+2 format 685 format for the alarm automation output from your AES receiver.
  • Page 3 2 minute phone line cut detection as well as generate and transmit a This position is for debug mode. This is only for use by AES. A jumper in restore line message to central receiver. During a phone line cut, the Tap will this position may cause the IntelliTap to not function, answer any phone number with 3 or more digits dialed by the panel.
  • Page 4 AES. This Warranty does not apply to any AES Product or any part thereof that has been altered in any way to affect its stability or reliability, or that has been subjected to abuse, mis- use, negligence, accident or act of God, or that has had the serial number effaced or removed.