GENERAL INSTALLATION INSTRUCTIONS
ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS FOR
LD(30, 36, 48, 60, 72, 84, 96)-N for use with Natural Gas or
IMPORTANT
WARNING:
alteration, service or maintenance can cause
injury
or
property
instructions thoroughly before installation.
f i r e - p a r t s . c o m
For assistance or additional information, consult
your gas log dealer, qualified installer, service
agency or gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
THIS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED
SOLID-FUEL BURNING FIREPLACE WITH A WORKING FLUE
The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum
Chimney Area shown below, based on a minimum chimney height of at least 8 feet. The area of the flue must not be less
than 1/10 the area of the fireplace opening. The flue must exhaust all products of combustion.
The chimney damper must be fixed in a manner to maintain permanent free opening as outlined above at all times. To
accomplish this, install the damper clamp (provided) on the edge of the damper blade to prevent its closing, drill a hole or
holes in the damper, or remove damper completely.
The minimum size of the fireplace in which the log set is to be installed must be as follows:
LOG SET SIZE
HEIGHT
30 INCH
36 INCH
42 INCH
48 INCH
54 INCH
60 INCH
66 INCH
72 INCH
84 INCH
96 INCH
"LD" Multi-Burner
Vented Gas Log Burner MODELS:
LD(30, 36, 48, 60)-P for use with Propane (LP) Gas
READ THESE INSTRUCTIONS CAREFULLY BEFORE
STARTING INSTALLATION OF LOG SET.
Improper
installation,
damage.
Read
IMPORTANT INFORMATION
CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL.
MINIMUM FIREPLACE SIZE IN INCHES
DEPTH
REAR WIDTH
26
20
30
22
30
22
34
22
34
22
34
22
34
22
34
22
34
22
34
22
12028 E. Philadelphia St. Whittier , CA 90601 U.S.A.
gaslogs@rasmussen.biz
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
these
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use
any phone in your building.
•
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
•
If you cannot reach your gas supplier, call the
fire department.
FRONT WIDTH
30
38
36
44
42
50
.
48
58
54
64
60
70
66
76
72
82
84
94
96
106
(562) 696-8718
FAX (562) 698-3510
www.rasmussen.biz
GAS PIPING
½" i.d.
½" i.d.
½" i.d.
3/4" i.d.
3/4" i.d.
1" i.d.
1" i.d.
1" i.d.
1" i.d.
1" i.d.
LD-705
CHIMNEY AREA
12 INCH DIAMETER
14 INCH DIAMETER
14 INCH DIAMETER
16 INCH DIAMETER
16 INCH DIAMETER
18 INCH DIAMETER
18 INCH DIAMETER
.
20 INCH DIAMETER
.
20 INCH DIAMETER
.
20 INCH DIAMETER