FG Europe LMTA Series Installation Manual

Wall mounted type

Advertisement

Quick Links

AIR CONDITIONER

Wall Mounted Type

[Original instructions]

1. SAFETY PRECAUTIONS

• Be sure to read this manual thoroughly before installation.
• The warnings and precautions indicated in this manual contain important information
pertaining to your safety. Be sure to observe them.
• Hand this manual, together with the operating manual, to the customer. Request the
customer to keep them on hand for future use, such as for relocating or repairing the
unit.
Indicates a potentially or imminently hazardous situation
WARNING
which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation that may result in
CAUTION
minor or moderate injury or damage to property.
• Installation of this product must be done by experienced service technicians or profes-
sional installers only in accordance with this manual. Installation by non-professional
or improper installation of the product might cause serious accidents such as injury,
water leakage, electric shock, or fi re. If the product is installed in disregard of the
instructions in this manual, it will void the manufacturer's warranty.
• Do not turn on the power until all work has been completed. Turning on the power be-
fore the work is completed can cause serious accidents such as electric shock or fi re.
• If refrigerant leaks when you are working, ventilate the area. If the leaking refrigerant
is exposed to a direct fl ame, it may produce a toxic gas.
• Installation must be performed in accordance with regulations, codes, or standards for
electrical wiring and equipment in each country, region, or the installation place.
• Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they
do not play with the appliance.
• Read carefully all safety information written in this manual before you install or use the
air conditioner.
• Install the product by following local codes and regulations in force at the place of
installation, and the instructions provided by the manufacturer.
• This product is part of a set constituting an air conditioner. The product must not be
installed alone or be installed with non-authorized device by the manufacturer.
• Always use a separate power supply line protected by a circuit breaker operating on all
wires with a distance between contact of 3 mm for this product.
• To protect the persons, earth (ground) the product correctly, and use the power cable
combined with an Earth Leakage Circuit Breaker (ELCB).
For authorized service personnel only.
WARNING
CAUTION

INSTALLATION MANUAL

Contents
1.
SAFETY PRECAUTIONS .................................................................. 1
2.
ABOUT THIS PRODUCT................................................................... 1
3.
GENERAL SPECIFICATION ............................................................. 2
4.
ELECTRICAL REQUIREMENT ......................................................... 2
5.
SELECTING THE MOUNTING POSITION ....................................... 3
6.
INSTALLATION WORK ..................................................................... 3
7.
ELECTRICAL WIRING ..................................................................... 5
8.
FINISHING ........................................................................................ 6
9.
FRONT PANEL REMOVAL AND INSTALLATION ............................. 6
10. TEST RUN ......................................................................................... 7
11. REMOTE CONTROLLER INSTALLATION ........................................ 7
12. OPTIONAL KIT INSTALLATION ........................................................ 7
13. INSTALLATION WORK (option) ........................................................ 8
14. SPECIAL INSTALLATION METHODS ............................................... 9
16. FUNCTION SETTING...................................................................... 10
17. CUSTOMER GUIDANCE ................................................................ 12
18. ERROR CODES .............................................................................. 12
• This product is not explosion proof, and therefore should not be installed in explosive
atmosphere.
• To avoid getting an electric shock, never touch the electrical components soon after
the power supply has been turned off. After turning off the power, always wait 5 min-
utes or more before you touch the electrical components.
• This product contains no user-serviceable parts. Always consult experienced service
technicians for repairing.
• When moving or relocating the air conditioner, consult experienced service technicians
for disconnection and reinstallation of the product.
• Do not place any other electrical products or household belongings under the product.
Condensation dripping from the product might get them wet, and may cause damage
or malfunction to the property.
• Be careful not to scratch the air conditioner when handling it.
• After installation, explain correct operation to the customer, using the operating manual.

2. ABOUT THIS PRODUCT

2.1. Precautions for using R410A refrigerant
The basic installation work procedures are the same as conventional refrigerant (R22)
models.
However, pay careful attention to the following points:
Since the working pressure is 1.6 times higher than that of conventional refrigerant (R22)
models, some of the piping and installation and service tools are special. (See the table
below.)
Especially, when replacing a conventional refrigerant (R22) model with a new refrigerant
R410A model, always replace the conventional piping and fl are nuts with the R410A
piping and fl are nuts.
Models that use refrigerant R410A have a different charging port thread diameter
to prevent erroneous charging with conventional refrigerant (R22) and for safety.
Therefore, check beforehand. [The charging port thread diameter for R410A is
1/2-20 UNF]
Be more careful that foreign matter (oil, water, etc.) does not enter the piping than with
refrigerant (R22) models. Also, when storing the piping, securely seal the opening by
pinching, taping, etc.
When charging the refrigerant, take into account the slight change in the composition of
the gas and liquid phases. And always charge from the liquid phase where refrigerant
composition is stable.
PART No. 9387082050-02
CAUTION
En-1

Advertisement

Table of Contents
loading

Summary of Contents for FG Europe LMTA Series

  • Page 1: Table Of Contents

    AIR CONDITIONER INSTALLATION MANUAL Wall Mounted Type PART No. 9387082050-02 Contents SAFETY PRECAUTIONS ..............1 ABOUT THIS PRODUCT..............1 GENERAL SPECIFICATION ............. 2 ELECTRICAL REQUIREMENT ............2 SELECTING THE MOUNTING POSITION ........3 INSTALLATION WORK ..............3 ELECTRICAL WIRING ..............5 FINISHING ..................
  • Page 2: General Specification

    The following items are necessary to install this air conditioner. (The items are not includ- 2.2. Special tools for R410A ed with the air conditioner and must be purchased separately.) Name Q’ty Name Q’ty Tool name Change from R22 to R410A Connection pipe assembly Wall cap Connection cable (4-conductor)
  • Page 3: Selecting The Mounting Position

    6.1. Installation dimensions 5. SELECTING THE MOUNTING POSITION Wall hook bracket 88 mm or more Decide the mounting position with the customer as follows: 70 mm or more 5.1. Indoor unit (1) Install the indoor unit level on a strong wall which is not subject to vibration. 140 mm (2) The inlet and outlet ports should not be obstructed : the air should be able to blow all or more...
  • Page 4 6.4. Installing the wall hook bracket CAUTION Insert the drain hose and drain cap into the drain port, making sure that it comes (1) Install the wall hook bracket so that it is correctly positioned horizontally and vertically. in contact with the back of the drain port, and then mount it. If the drain hose is not If the wall hook bracket is titled, water will drip to the fl...
  • Page 5: Electrical Wiring

    Dimension A [mm] Flare nut [mm (in.)] Tightening torque [N·m (kgf·cm)] Pipe outside diameter Flare tool for R410A, Dimension B [mm] 6.35 (1/4) dia. 16 to 18 (160 to 180) [mm (in.)] clutch type 9.52 (3/8) dia. 32 to 42 (320 to 420) 6.35 (1/4) 12.70 (1/2) dia.
  • Page 6: Finishing

    (3) Connect the end of the connection cable fully into the terminal block. (5) Fasten the drain hose to the outside wall, etc. Outside wall cap* Saddle* Sealer putty* 1 2 3 (Outdoors) Pipe Wall *Locally purchased Overlap the insulation Connection pipe (heat insulation) Indoor unit pipe...
  • Page 7: Test Run

    (4) Remove 10 screws. By the wired remote controller  For the operation method, refer to the installation manual and the operating manual of Screws (Wire cover) the wired remote controller. The Operation indicator lamp and Timer indicator lamp will simultaneously fl ash during the test run mode.
  • Page 8: Installation Work (Option)

    12.1.3. Connection methods External input and output 12.1. Wire modifi cation 12.1.1. External input • Remove insulation from wire attached to wire kit connector. • Remove insulation from locally purchased cable. Use crimp type insulated butt • Indoor unit functions such as Operation/Stop or Forced stop can be done by using connector to join fi...
  • Page 9: Special Installation Methods

    Select the appropriate cable depending on the total wiring length. Installing the external connect kit 13.2. Total wiring length of remote controller cable Cross section of cable (1) Install the cable as shown in the following photograph. Be sure to place the wiring under the tabs. (A+B+C+D+E) 500 m or less 0.3-1.25 mm...
  • Page 10: Remote Controller Custom Code Setting

    (4) Press the “MODE” button once to send the function setting information. Please con- 15. REMOTE CONTROLLER CUSTOM CODE SETTING fi rm the beeping sound. (5) Next, please press START/STOP ( ) button once to fi x the function setting. Please When two or more air conditioners are installed in a room and the remote controller is confi...
  • Page 11 Room temperature control for wired remote controller sensor Room temperature sensor switching (Aux.) To use the temperature sensor on the wired remote controller only, change the setting to Depending on the installed environment, correction of the wire remote temperature sensor “Wired remote controller”...
  • Page 12: Customer Guidance

    Display PCB microcomputers 17. CUSTOMER GUIDANCE ● ● ◊ (10) communication error Discharge temp. sensor error Explain the following to the customer in accordance with the operating manual: ● ● ◊ (1) Starting and stopping method, operation switching, temperature adjustment, timer, air fl...

Table of Contents