  • Page 1 Professional 36” Range RG3F, RG3G, RG3R & RG36 models Professional 48” Range RG4D, RG4F, RG4G, RG4R & RG4T models Professional 72” Range Installation guide RG68BFTGD & RG66BFT2GD models Professional 36” Rangetop CG3F, CG3G, CG3R & CG36 models Professional 48” Rangetop CG4D,CG4F, CG4G, CG4R &...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WARNING To reduce the risk of tipping the appli- ance, the appliance must be secured A MESSAGE TO OUR CUSTOMERS by properly installed anti-tip device packed with the appliance. SAFETY PRACTICES AND PRECAUTIONS • A child or adult can tip the range and be killed.
  • Page 3: A Message To Our Customers

    Thank you for selecting this professional Range. Because of this appliance's unique features we have When properly cared for, your new Caliber Appliance has been designed to be a safe, reliable developed this Installation Guide. It contains valuable information on how to properly install your new cooking appliance.
  • Page 4 • Do not remove the grease drip-pan from the griddle or grill until completely cool. Caliber Appliances recommends installing the manual shut-off valve in a location readily accessible by the • For proper lighting and performance of the rangetop burners, keep the burner ports clean. It may customer, so that gas to the appliance can be shut off in an emergency situation.
  • Page 5: Models

    (surface cooking only - no ovens): (surface cooking only - no ovens): CG4D,CG4F, CG4G, CG4R & CG4T CG3F, CG3G, CG3R & CG36 Professional 48” Range Models: RG4D, RG4F, RG4G, RG4R & RG4T Professional 36” Range Models: RG3F, RG3G, RG3R & RG36...
  • Page 6: Planning The Installation

    - See section 'Backguard Installation'. All range and rangetops have a standard 2 5/8" integral island trim. • For all ranges and rangetops, the full backguard may be purchased separately from Caliber (see specifications information below in Fig.1). Full Backguard Specifications Professional 72”...
  • Page 7: Unpacking And Handling

    UNPACKING AND HANDLING PLANNING THE INSTALLATION Kick Panel (range models) RECOMMENDED INSTALLATION SEQUENCE MOVING AND PLACING THE RANGE (cont.) Install components in the following order: 1. Locate and level range according to range and rangetop installation instructions. Anti-tip device should be Installed (see section 'Installing anti-tip device' for instructions).
  • Page 8: Ventilation Requirements

    UNPACKING AND HANDLING VENTILATION REQUIREMENTS A suitable exhaust hood must be installed above the range. The following chart indicates the minimum blower capacity recommended for hood ventilation. Ventilation Unit Standard Counter Installation Island Installation To remove door: Recommendations Recommendations HOOD 23”...
  • Page 9: Cabinet Preparation

    The bracket engages the post of the leveling leg to prevent tipping. Important! Caliber Appliances recommends Installing the manual shut-off valve In a location readily WOOD CONSTRUCTION: accessible by the customer, so that gas to the appliance can be shut off in an emergency Place the bracket against the back wall, into the right rear corner where the range is to be located.
  • Page 10 CABINET PREPARATION CABINET PREPARATION LOCATION OF ELECTRICAL & GAS SUPPLY- RG3, RG4 & RG6 RANGE MODELS Supply area dimensions RG4D-48 RG3F-36 CG4D-48 CG3F-36 (see diagram figures 6-12 for further RG68BFTGD-72 RG4F-48 RG3G-36 CG4F-48 CG3G-36 clarification) RG66BFT2GD-72 RG4G-48 RG3R-36 CG4G-48 CG3R-36...
  • Page 11 28 1/4” 28 1/4” 28 1/4” CALIBER INDOOR PROFESSIONAL RANGE SERIES SPECIFICATIONS CALIBER INDOOR PROFESSIONAL RANGETOP SERIES SPECIFICATIONS 48” Rangetop 36” Rangetop Models Models Full height to vent hood backsplash with shelf accessory models also available in Stainless Steel with Stainless Steel Shelves...
  • Page 12: Backguard Installation

    Use the appropriate range backguard. See also "Planning The Installation" section. mount. Full backguard models are available from Caliber, but For all models, Caliber Appliances backguards are sold separately. not required. ELECTRICAL CONNECTIONS Fig. 14 The rating label is located on the back of the range and rangetop.
  • Page 13: Gas Hook-Up

    Verify the type of gas supplied to the location. The range is shipped from the factory set up Caliber Appliances recommends installing the manual shutoff valve in a location and adjusted for Natural Gas or LP (propane), depending on the specific model ordered from readily accessible by the customer, so that gas to the appliance can be shut off in an the Factory.
  • Page 14: Test And Adjustments

    WARNING!: yellow, indicating insufficient air, adjust the shutter counterclockwise For warranty coverage, Caliber Appliances requires that burner to increase air inlet. If the flame is noisy or tends to lift away from the adjustments be made by a qualified technician at the time of burner, indicating too much air, turn the shutter clockwise to reduce installation.
  • Page 15: Installer Final Checklist

    Radiant tray placed in grill unit (if equipped). The grill grate is in place. To obtain service, please contact Caliber Appliances at (714) 848-1349 or go to our website at www.caliberappliances.com and choose “CONTACT” to email us the service needed. Before you call,...
  • Page 16: French Warnings

    MESURES DE SÉCURITÉ ET DE PRÉCAUTION MESURES DE SÉCURITÉ ET DE PRÉCAUTION Votre nouvel appareil Caliber fonctionnera de manière sûre et fiable pendant des années si vous • Utilisez seulement des gants isolants secs : les gants humides sur des surfaces chaudes peuvent en prenez bien soin.
  • Page 17 à proximité. L’élément Caliber recommande d’installer le robinet d’arrêt manuel dans un endroit facilement accessible par le client pour couper l’alimentation en gaz en cas d’urgence. Cependant, l’appareil ne doit pas être modifié de quelque façon chimique qui produit le jet de vaporisation peut, en présence de chaleur, s’enflammer ou...
  • Page 18 Caliber Appliances 17812 Metzler Lane Huntington Beach, CA 92647 714-848-1349 www.caliberappliances.com Copyright © Caliber Appliances 2019. All rights reserved. The product specifications in this booklet apply to the specific products and models described at the date of issue. Under our policy of continual product improvement, these specifications may change at any time.