Schritt
1
Gateway installieren
Wechselrichter / Inverter
SOLIVIA Gateway M1 G2
DATA+ (Pin 3 oder / or 5)
TX_A (Pin 7)
DATA– (Pin 4 oder / or 6)
RX_B (Pin 6 oder / or 8)
GND (Pin 2)
GND (Pin 4)
SOLIVIA Gateway M1 G2
Pin
Bezeichnung
Assignment
1
Reserviert
Reserved
1
8
2
Reserviert
Reserved
3
Reserviert
Reserved
4
GND
GND
5
Reserviert
Reserved
6
RX_B
RX_B
7
TX_A
TX_A
8
RX_B
RX_B
Inverter
Pin
Bezeichnung / Assignment
1 2 3 4 5 6
1
VCC (+12 V)
2
GND
3
D+ (DATA+)
4
D– (DATA–)
5
D+ (DATA+)
6
D– (DATA–)
Die Bilder zeigen die Position der RS485-Anschlüsse an den einzelnen RPI Wechselrichtern.
An jedem Wechselrichter eine andere RS485-ID einstellen. An jedem Wechselrichter die Baudrate auf den Standard-
wert 19200 einstellen. Am letzten Wechselrichter in der Reihe muss der Abschlusswiderstand eingeschaltet sein (siehe
Installationskurzanleitung des Wechselrichters).
Für den Anschluss eines Blindleistungssteuerung-Empfängers siehe Komplett-Handbuch des SOLIVIA Gateways.
Unbedingt das mitgelieferte Netzteil mit dem für Ihr Land passenden Adapter benutzen.
Für die Netzverbindung ist ein Standard-Ethernet-Kabel ausreichend.
Es wird ein Computer mit Internetbrowser benötigt. Dieser muss mit dem Internet verbunden sein.
Das Gateway erhält automatisch eine IP-Adresse von dem DHCP-Server im Kundennetzwerk. Es ist keine manuelle
Konfi guration notwendig.
Nach Abschluss der Installation
können Sie am Status der LED den
Status der Kommunikationsverbin-
dungen prüfen.
30.06.2015
- Alle Informationen und Spezifi kationen unterliegen Änderungen ohne vorherige Ankündigung
Schnellanleitung
EUROPA / AUSTRALIEN
RPI M15A / M20A
+
+
+
+
DC 1
DC 2
DC INPUT
AC OUTPUT
RS485
COM
RS485
COM
RPI H3
RPI H4A / H5A
LED Status
Beschreibung
Dauerleuchten: Kein Ethernet; keine Verbindung zum
Wechselrichter
300
300
Schnelles, gleichmäßiges Blinken: Ethernet vorhanden;
ms
ms
keine Verbindung zum Wechselrichter
Langsames, gleichmäßiges Blinken: Kein Ethernet;
1 s
1 s
Verbindung zum Wechselrichter vorhanden
200
1800
Kurzes, gleichmäßiges Aufblitzen: Ethernet vorhanden;
ms
ms
Verbindung zum Wechselrichter vorhanden
Sehr schnelles Blinken, Gesamtdauer 1 s, Reset-Knopf
ms
ms
wurde gedrückt.
Quick Installation Guide
EUROPE / AUSTRALIA
RPI M30A / M50A
DC1
DC2
OFF
ON
COMM.
DC SWITCH
DC INPUT
RESET
RS485
RPI
M6A / M8A / M10A
The fi gures show the position of the RS485 connections on the individual RPI inverters.
Set a different RS485 ID on each inverter. Set the baudrate to the standard value 19200 on each inverter.
The termination resistor on the last inverter in the series must be switched on (see quick installation guide).
For the connection of a reactive power control receiver see the complete SOLIVIA Gateway manual.
Make sure that you use the appropriate adapter for your country with the provided power supply unit.
A standard Ethernet cable is suffi cient for the network connection.
A computer with an Internet browser connected to the Internet is required.
The gateway automatically obtains an IP address from the DHCP server in the customer network. Manual confi guration
is not required.
After completion of the installation
you can check the status of the com-
munication connections on the LED
status.
STATUS
GW
EXT. CONTROL
RS485
LAN
INPUT
1 2 3 4 5 6 7 8 A B
5V
30.06.2015 © Copyright – Delta Energy Systems (Germany) GmbH
Tscheulinstraße 21 • 79331 Teningen • Deutschland
LED status
Continuous light: no Ethernet; no connection to the
inverter
300
300
Quick, even blinking: Ethernet available; no connection
ms
ms
to the inverter
Slow, even blinking: no Ethernet; connection to the
1 s
1 s
inverter available
200
1800
Short, even fl ashing: Ethernet available; connection to
ms
ms
the inverter available
Very quick blinking, total duration 1 s, reset button has
ms
ms
been pressed.
Step
Installing gateway
1
ETHERNET / LAN
INTERNET
SOLIVIA
Monitor
5017010501 01
Description
30.06.2015
-
All information and specifi cations are subject to change without notice

Advertisement

loading

Summary of Contents for Delta SOLIVIA Gateway M1 G2

  • Page 1 D+ (DATA+) D– (DATA–) D+ (DATA+) D– (DATA–) 30.06.2015 © Copyright – Delta Energy Systems (Germany) GmbH Tscheulinstraße 21 • 79331 Teningen • Deutschland 5017010501 01 The fi gures show the position of the RS485 connections on the individual RPI inverters.
  • Page 2 Open the Internet browser on your computer and go to the website http://monitoring.solar-inverter.com Melden Sie sich hier an, wenn Sie Sign in here if you already have a schon ein Delta Benutzerkonto haben. Delta user account. Wenn Sie noch keine Benutzer- If you do not have a user konto bei Delta haben, können...