General Information About Fireplace Work; Fuel; Regulation Of The Air Regulators - Color Emajl L1 Manual For Use And Installation

Table of Contents

Advertisement

Table 2: Technical specifications
Always use gloves!
Do not use any flammable liquid fluids for lighting fire. The door of the stokehole can be opened only when adding
fuel. Use only suitable fuels (see the table below). Check, is there enough quantity of fresh air in the room, when
working on the open principle. Fireplaces can be used only by adults. Make sure that children are never alone near
fireplace.
Never leave fireplace for a longer period of time without surveillance.

Fuel

Firewood
Briquettes (coal)
Table 3: Regulation of the air regulators
1.
Primary and secondary regulators open maximally!
Be careful, if the flue pipe has integrated flap it should also be opened maximally.
2.
2-3 cubes for fire, place on the center of the stokehole and put on it firewood.
3.
Light the cubes and just lean the door. It prevents condensation of gas on the cold glass.
4.
After approximately 5 to 10 minutes, when the fire is fully burst, carefully open the door, put 1 to 2 pieces of the
wood into the stokehole, and then close the door.
5.
When the amount of putted fueled material becomes well flamed and burst, and the working temperature of the
fireplace is achieved, gradually move the primary air regulator backwards, but the flame still must be further visible.
At optimum sub pressure and qualitative fuel, the primary regulator can be completely closed. Now you regulate the
fire using the secondary regulator.
6.
The door of the stokehole can be opened again, only when the placed quantity of the fuel is burned, and when you
want to put the new fuel.
7.
It is recommended that the secondary air regulator is kept maximally opened, in order for the "glass cleaning" to
become maximally efficient, and to avoid glass "fogging".
8.
With fuel quantity regulate the necessary heat of your room. Excessive fireplace work brings to unnecessary
environment overload, moreover stokehole, glass and flue pipe pollution.
9.
When using brown coal briquette, leave primary air regulator open.
Possible odor appearance that generates due to protective paint drying will disappear after a short while. If the odor
appears, open the windows of the room for a ventilation.
General information about fireplace work
Fuel quantity
2 – 3 pcs
2,5 kg
Primary air
Max ½
Open
Start
Secondary air
Open
cca. 1/4
5/6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L1 and is the answer not in the manual?

This manual is also suitable for:

L2L3