4
Shut Down Mode
Pressing the power button after the first minute of operation will initiate a shut-down mode. This mode
will last 15 minutes and will maintain the operation of the fan and purge pump to insure all water is
removed from the unit prior to moving or storing. Pressing the power button at any time during the shut
down mode will immediately shut down the unit and bypass the remainder of the shutdown mode. The
unit must be purged by pressing the purge button if bypassing the shutdown mode to avoid water
overflow.
The display will change during shutdown mode to a countdown timer that will indicate the
time remaining before the unit shuts completely off.
Functions
Loss of Power Recovery Function
In case of a loss of power, the last run state (ON or OFF) will be maintained when the power is
restored.
Pump Purge Function
In normal operation, the pump will automatically empty the reservoir. Pressing the purge button
(figure 9) runs the pump for 1 minute allowing manual emptying of the reservoir. The pump purge
will function in all modes as long as the unit is plugged in.
Hour Meter Display
The cumulative hours will be displayed during normal operation. If the unit is off (even unplugged)
pressing the hour button (figure 10) will also display the accumulative hours briefly.
Venting / Ducting
Twin rear outlets (figure 11) can accommodate two individual 5" ducts or one 10" lay flat duct to be
Venting / Ducting (Fig. 6)
attached. This allows for warm dry air to be directed into different areas.
Twin rear outlets can accommo-
date two individual 5" ducts or one
10" lay flat duct to be attached.
This allows for warm dry air to be
Maintenance
directed into different areas.
Air Filter
The air filter should be checked regularly. Operating the dehumidifier with a clogged filter will reduce
Maintenance
efficiency. To access the filter, slide the filter frame up until it clears the dehumidifier cabinet
(figure 12). Reverse procedure to re-install the filter into the dehumidifier. Metal filters should be
Air Filter (Fig. 7)
washed with soap and water, and paper filters should be replaced.
The air filter should be checked regularly. Operating the dehu-
midifier with a clogged filter will reduce efficiency. The filter can be
vacuum cleaned to remove dust. To access the filter media, slide
Paper filter size is a nominal 12" x 12" x 1"
the filter frame up until it clears the dehumidifier cabinet. Remove
the filter media from behind the frame and vacuum. Reverse pro-
Operating the unit without the filter in place will cause reduced efficiency due to dirty coils and
cedure to re-install the filter and frame into the dehumidifier.
increase the frequency of internal coil cleaning.
Stacking
The dehumidifiers can be stacked on top of each other (figure 13). The wheels from the upper unit
must be resting in the cradle of the lower unit. DO NOT STACK MORE THAN TWO HIGH.
Battery Replacement
Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death, fire, or electrical shock
Disconnect dehumidifier from power supply. The hour meter uses a battery backup for display when the
dehumidifier is unplugged and the hour button is depressed. To change the battery, it is necessary to remove
Cleaning
the four (4) screws from the control panel. Disconnect the old battery and replace with new battery.
Replace control panel and screws. Do not overtighten screws.
fantech
Fig. 6
Fig. 7
WARNING
Venting / Ducting (Fig. 6)
Twin rear outlets can accommo-
date two individual 5" ducts or one
10" lay flat duct to be attached.
This allows for warm dry air to be
directed into different areas.
Fig. 8
Maintenance
Air Filter (Fig. 7)
The air filter should be checked regularly. Operating the dehu-
midifier with a clogged filter will reduce efficiency. The filter can be
vacuum cleaned to remove dust. To access the filter media, slide
the filter frame up until it clears the dehumidifier cabinet. Remove
Storage
the filter media from behind the frame and vacuum. Reverse pro-
Freezing temperatures and biological growth must be considered
before storing the dehumidifier. The dehumidifier should be
cedure to re-install the filter and frame into the dehumidifier.
flushed with a biofungicide before storing. When storing the unit,
ensure that water has been removed from the reservoir and
Fig. 7
hose. This will prevent damage caused by freezing temperatures
and to prevent biological growth. Use the pump purge button to
remove water and biofungicide chemicals from the dehumidifier.
Stacking (Fig.9)
The dehumidifiers can be stacked on top of each other. The
wheels from the upper unit must be resting in the cradle of
the lower unit. DO NOT STACK MORE THAN TWO HIGH.
Fig. 9
Cleaning
Service
WARNING
A qualified refrigeration technician must service all refriger-
ant leaks.
WARNING: The dehumidifier uses a high pressure refrigerant
system and high voltage circuitry which could present a health
hazard resulting in death, serious bodily injury, and/or property
Figure 9
Figure 10
Fig. 6
Figure 11
Figure 12
Figure 13
F
Stor
Free
befor
flush
ensu
hose
and t
remo
Stac
The
whee
the lo
Fig
Ser
A qu
ant l
WAR
syste