LIMITED YEAR ARRANTY Auper Electronic Controls Inc. warrants that this product is in good working condition, according to its specifications at the time of the shipment, for a period of FIVE (5) years from the date of purchase. Should the product, in Auper Electronic Controls Inc opinion, malfunction within the warranty period, Auper Electronic Controls Inc.
Page 3
Inc. with respect to any defective product will be limited to the repair or replacement of such product. In no event shall Auper Electronic Controls Inc be responsible or liable for any damages arising (a) from the use of the product;...
Page 4
The entire risk as to the quality of output developed with this product is assumed by the user. Auper Electronic Controls Inc does not warrant that the software or system will meet any particular requirements of the user, other than...
Page 5
25 ft (7.62 m) flow meter collector cable 10 ft (3 M) serial cable or Cat 5 network cable PTIONAL WiFi adapter USB to serial adapter Serial printer Draft Manager Live software TM6400 Installation & User guide P a g e...
COMMUNICATION The TM6400 is equipped with two programmable serial ports and an Ethernet adapter to connect it to a computer network. The RS-422 port serial port connector is a RJ11 jack (phone jack).
Maximum Baud Rate RS-232 115kbit/s ETHERNET ADAPTER The TM6400 is available with an optional Ethernet adapter you can use to connect one, or several TM6400, directly to your computer network to use the Draft Manager Live software. Once connected to a network port, the adapter can be found and configured by remote login by our technicians from any PC on the same network.
Page 8
TM6400 FLOW MONITORING SYSTEM RED LED POWER FAIL INDICATOR The red LED on the TM6400 will flash to signal that there was a power failure. To stop the LED from flashing you will need to enter your administrator code. ONNECTING THE FLOW METERS...
Page 9
You can find them in computer stores or have them installed by local computer network contractors. However, you must not connect the collector cables to the computer network and each cable should be tested priot to connecting it to the collector and TM6400 system.. P a g e...
Page 10
TM6400 FLOW MONITORING SYSTEM There are two channels on the TM6400 each able to take one or 2 collector boxes. Channel 1 on the TM6400 (flow meters No.1 to 32) will take one or two collector boxes. The second collector boxe (flow meter 17 to 32) connects to the first collector box using the OUT connector to the IN connector of the first collector box.
Page 11
If two wires are touching, the flow meter signal will be shorted and the flow meter will not send any signal to the TM6400. Connect the network cable to the collector box. Secure all your cables using cable ties.
Make sure the power source cannot be disconnected by the staff. A UPS (battery backup) is an added security since it will supply power to a TM6400 for a long time in case of power failures insuring continuous power to the unit.
TM6400 FLOW MONITORING SYSTEM AND TRANSMITTER POWER UP AND SET UP The button serves several functions. 1. The numbers will be used for passwords. 2. Arrow signs pointing left and right will be used to move the cursor, select the line numbers or ports viewed.
If a flow meter is installed backward, the corresponding dot will be up but will not alternate when product is flowing. TM6400 Installation & User guide 13 | P a g e...
Page 15
2. Calibration (Please read carefully) The TM6400 can be set to measure ounces, litres, gallons etc... To calibrate, you will serve a measured amount of liquid into a graduated cylinder during which time the system will count the number pulses sent by the flow meter.
Page 16
After pressing the E button to calibrate all the flow meters, you can come back and resample the one(s) you are not satisfied with. Press M to exit calibration mode Press E to confirm. TM6400 Installation & User guide 15 | P a g e...
Page 17
0 since the default number in the software is also 0. If you have more than one TM6400, you can change the number of the other systems to 1, 2 3 etc…. Each TM6400 has to be set with a different number when on the same network. Two systems with the same number will cause an error since both will respond to the same command sent by the software.
9600 is the default Windows baud rate. If you change it in the TM6400, it has to be changed in the software as well. The TM6400 is designed to operate at 115.2 K for a much faster transmission rate. Press M to go to the next mode.
USB to serial converter Default Windows serial port settings: 9600 bps bits no parity, 2 stop bits Flux control to none. P/N: 70-080 Use with Auper null modem serial cable P/N: 70.010 18 | P a g e...
Page 20
You do not have an available computer network to use the network adapter. You wish to connect your TM6400 to a computer more than 150 ft (50M) away. You have more than one metering system that you want to connect to the same computer or printer.
Page 21
The IP address of the computer hosting Draft Manager Live must be set to static (not DHCP). A change in the IP address would disconnect the TM6400 system (unless connected by COM port) and the POS if interfaced. The software is equipped with a tool to find the Auper devices connected to the computer network.
Page 22
NOTES: TM6400 Installation & User guide 21 | P a g e...