WARNING Please read these instructions carefully before assembling and using the equipment. Improper installation or use may result in injury or damage. • If a problem occurs during installation, please contact your local qualified fitter. • If the accessories are damaged or lost, please report to your supplier. •...
INSTALLATION STEPS STEP 1 Connect base and column with 4 screws(M6*14), then plug the control box cord into column connector. STEP 2 Connect base support block and column with 4 sunk screws(M6*8).
Page 5
STEP 3 Plug the controller into the control box and raise the shelf a small bit. Install the table top with 4 sunk screws (M6*25). STEP 4 Install monitor bracket support with 4 sunk screws (M6*12).
Page 6
STEP 5 Set-Up of desk converter is complete...
TROUBLE SHOOTING LED flashing ‘RST’ – System should be reset Ensure all the power cords, connecting cables and handset cord are connected correctly Press ‘V’, the actuators will move down to the lowest position Press ‘V’ again and hold until ‘RST’ flashes on the LED Press ‘V’...
Page 9
LED displays E01 - Overcurrent protection. Operation: 1. Press any button, LED will display “RST”. 2. Reset. LED displays E07 - Abnormal Height Limit. Operation: 1. Press any button, LED will display “RST”. 2. Reset. LED displays H01 - Overheating/Work protection. Operation: Rest for 18 minutes first, and then operate.