Fluidwell F127-P-EL-TA Operation Manual

Differential flow computer for corrected liquid volume, signal input flowmeter: pulse, namur and coil, signal input temperature: 0 4-20ma, signal outputs: 4-20ma ref. corrected flowrate, options: intrinsically safe, modbus communication
Hide thumbs Also See for F127-P-EL-TA:

Advertisement

Quick Links

F127-P-EL-TA
DIFFERENTIAL FLOW COMPUTER
FOR CORRECTED LIQUID VOLUME
Signal input flowmeter: pulse, namur and coil.
Signal input temperature: (0)4-20mA.
Signal outputs: 4-20mA ref. corrected flowrate.
Options: Intrinsically Safe, Modbus communication.
F-Series - Field mounted indicators for safe and hazardous areas. More info: www.fluidwell.com/fseries

Advertisement

Table of Contents
loading

Summary of Contents for Fluidwell F127-P-EL-TA

  • Page 1 DIFFERENTIAL FLOW COMPUTER FOR CORRECTED LIQUID VOLUME Signal input flowmeter: pulse, namur and coil. Signal input temperature: (0)4-20mA. Signal outputs: 4-20mA ref. corrected flowrate. Options: Intrinsically Safe, Modbus communication. F-Series - Field mounted indicators for safe and hazardous areas. More info: www.fluidwell.com/fseries...
  • Page 2: Safety Instructions

     Intrinsically Safe applications: follow the instructions as mentioned in Chapter 5 and consult “Fluidwell F1..-..-XI - Documentation for Intrinsic Safety”. DISPOSAL At the end of its life this product should be disposed of according to local regulations regarding waste electronic equipment.
  • Page 3: About The Operation Manual

    This operation manual describes the standard unit as well as most of the options available. For additional information, please contact your supplier. A hazardous situation may occur if the F127-P-EL-TA is not used for the purpose it was designed for or is used incorrectly. Please carefully note the information in this operating manual indicated by the pictograms: A "warning"...
  • Page 4: Table Of Contents

    Page 4 CONTENTS MANUAL Safety instructions ............................2 Safety instructions ............................2 Safety rules and precautionary measures ....................... 2 About the operation manual ..........................3 Introduction ..........................5 1.1. System description of the F127-P-EL ..................5 Operational ..........................7 2.1. General ..........................
  • Page 5: Introduction

    Page 5 INTRODUCTION 1.1. SYSTEM DESCRIPTION OF THE F127-P-EL Functions and features The flowcomputer Model F127-P-EL is a microprocessor driven instrument for the calculation of standard volumetric flow or mass flow for differential flow measurement applications using flow equations. This product has been designed with a focus on: ...
  • Page 6 The following options are available: isolated or active 4-20mA / 0-10V / 0-20mA analog output, full Modbus communication RS232/485 (also battery powered), intrinsic safety, power- and sensor- supply options, panel-mount, wall-mount and weather-proof enclosures, flame proof enclosure. Important: for Model F127-P-EL-TA, option PM (80-230V AC power supply) is not available. HF127PEN_EL_TA_v0501_04...
  • Page 7: Operational

    Page 7 OPERATIONAL 2.1. GENERAL  The F127-P-EL may only be operated by personnel who are authorized and trained by the operator of the facility. All instructions in this manual are to be observed.  Take careful notice of the " Safety rules, instructions and precautionary measures " in the front of this manual.
  • Page 8: Operator Information And Functions

    Page 8 2.3. OPERATOR INFORMATION AND FUNCTIONS In general, the F127-P-EL will always function at Operator level. The information displayed depends upon the SETUP-settings. All pulses generated by the connected flowmeter are measured by the F127-P-EL in the background, whichever screen refresh rate setting is chosen. After pressing a key, the display will be updated quickly during a 30 second period, after which it will slow down again.
  • Page 9: Configuration

    Page 9 CONFIGURATION 3.1. INTRODUCTION This and the following chapters are exclusively meant for electricians and non-operators. In these, an extensive description of all software settings and hardware connections are provided.  Mounting, electrical installation, start-up and maintenance of the instrument may only be carried out by trained personnel authorized by the operator of the facility.
  • Page 10 Page 10 Matrix structure SETUP-level: SCROLLING THROUGH SETUP-LEVEL Selection of function-group and function: SETUP is divided into several function groups and functions. Each function has a unique number, which is displayed below the word "SETUP" at the bottom of the display. The number is a combination of two figures. The first figure indicates the function-group and the second figure the sub-function.
  • Page 11 Page 11 To change or select a value: To change a value, use  to select the digits and  to increase that value. To select a setting, both  and  can be used. If the new value is invalid, the increase sign or decrease-sign will be displayed while you are programming.
  • Page 12: Overview Functions Setup Level

    Page 12 3.2.2. OVERVIEW FUNCTIONS SETUP LEVEL SETUP FUNCTIONS AND VARIABLES TOTAL - A UNIT L - m3 - kg - lb - GAL - USGAL - bbl - no unit DECIMALS 0 - 1 - 2 - 3 (Ref: displayed value) K-FACTOR: 0.000010 - 9,999,999 DECIMALS K-FACTOR...
  • Page 13: Explanation Of Setup-Functions

    Page 13 ANALOG OUTPUT disable - enable 4mA / 0V 0000.000 - 9,999,999 20mA / 10V 0000.000 - 9,999,999 CUT-OFF 0.0 - 9.9% TUNE MIN - 4mA / 0V 0 - 9,999 TUNE MAX- 20mA / 10V 0 - 9,999 FILTER 00 - 99 COMMUNICATION...
  • Page 14: Flowrate A

    Page 14 1 - TOTAL A (CONTINUED) This setting determines the number of decimals for the K-factor entered. DECIMALS K-FACTOR (SETUP 13). The following can be selected: 0 - 1 - 2 - 3 - 4 - 5 - 6 Please note that this setting influences the accuracy of the K-factor indirectly.
  • Page 15: Total B

    Page 15 2 - FLOWRATE A (CONTINUED) ILTER VALUE ESPONSE TIME ON STEP CHANGE OF ANALOG VALUE IME IN SECONDS INFLUENCE INFLUENCE INFLUENCE INFLUENCE filter disabled filter disabled filter disabled filter disabled 0.1 second 0.2 second 0.4 second 0.7 second 0.2 second 0.4 second 0.6 second...
  • Page 16: Display

    Page 16 5 - DISPLAY The large 17mm digits can be set to display total or flowrate. FUNCTION When "total" is selected, both total and flowrate are displayed simultaneously. When "flowrate" is selected, only flowrate will be displayed with it’s measuring unit while total will be displayed after pressing SELECT.
  • Page 17: Power Management

    Page 17 6 - POWER MANAGEMENT When used with the internal battery option, the user can expect reliable measurement over a long period of time. The F127-P has several smart power management functions to extend the battery life time significantly. Two of these functions can be set: The calculation of the display-information influences the power LCD NEW consumption significantly.
  • Page 18: Temperature - A

    Page 18 20mV Sensitive for COIL HI High sensitive coil input p.t.p. disturbance! 90mV COIL LO Low sensitive coil input Normal sensitivity p.t.p. Active pulse input External power ACT_8.1 10KHz. 8.1 VDC required Active pulse input External power ACT_12 10KHz. 12 VDC required Active pulse input...
  • Page 19 Page 19 8 - TEMPERATURE - A (CONTINUED) With this setting it is possible to calibrate the input value for (0)4mA as the CALIBRATE LOW signal from the sensor might not be exact 4.0 mA (or 0.0 mA) at “offset- temperature”...
  • Page 20: Temperature - B

    Page 20 9 - TEMPERATURE - B Conversion formula’s temperature units: x K = (x-273,15)°C = (9/5x-459,67)°F x°C = (x+273,15) K = 9/5x+32°F x°F = 5/9(x-32)°C = 5/9(x+459,67) K Read also par. 4.4.3. Temperature input terminal 12-14. With this setting, the measurement range of the (0)4-20mA temperature SPAN sensor is determined in Kelvin (K).
  • Page 21: A - Formula

    Page 21 A - FORMULA This function describes the supplied equations. EQUATIONS TYPE The supplied Model is the F127-P-EL. “EL” stands for Equations Liquid - flowcomputer for corrected liquid volume. The formula used: = Q * (1 + α (T - T)) normal normal...
  • Page 22: B - Analog Output

    Page 22 B - ANALOG OUTPUT A linear 4-20mA signal (option AB: 0-20mA or option AU: 0-10V) output signal is generated according to the calculated flowrate with a 10 bits resolution. The settings for flowrate (SETUP - 2) directly influence the analog output. Note: When the analog output is not used, please make sure that setting B1 is disabled, or else the battery life time will be reduced significantly! When a power supply is available but the output is disabled, a 3.5mA signal will be generated.
  • Page 23: C - Communication (Optional)

    Page 23 B - ANALOG OUTPUT (CONTINUED) This function is used to stabilize the analog output signal. FILTER The output value is updated every 0.1 second. With the help of this digital filter a more stable but less precise reading can be obtained. The filter principal is based on three input values: the filter level (01-99), the last analog output value and the last average value.
  • Page 24: Installation

    Page 24 INSTALLATION 4.1. GENERAL DIRECTIONS  Mounting, electrical installation, start-up and maintenance of this instrument may only be carried out by trained personnel authorized by the operator of the facility. Personnel must read and understand this Operating Manual before carrying out its instructions. ...
  • Page 25: Dimensions- Enclosure

    Page 25 4.3. DIMENSIONS- ENCLOSURE Aluminum enclosures: 75 mm (2.95") 112 mm (4.40") 130 mm (5.12") 12mm 12mm 30mm 30mm 24mm 24mm M20 x 1,5 6 x M12 36mm 36mm 30mm 30mm M16 x 1,5 M16 x 1,5 1/2"NPT M20 x 1,5 0.12"...
  • Page 26 Page 26 GRP enclosures: 75 mm (2.95") 112 mm (4.40") 130 mm (5.12") HK back box: (flat bottom) 75 mm (2.95") 118 mm (4.65”) 25mm 25mm D=20mm D=20mm 12mm 12mm 30mm 30mm 24mm 24mm D=12mm D=16mm D=16mm D=20mm 36mm 36mm 0.12”...
  • Page 27: Installing The Hardware

    Page 27 4.4. INSTALLING THE HARDWARE 4.4.1. INTRODUCTION  Electro static discharge does inflict irreparable damage to electronics! Before installing or opening the unit, the installer has to discharge himself by touching a well-grounded object.  This unit must be installed in accordance with the EMC guidelines (Electro Magnetic Compatibility).
  • Page 28: Voltage Selection Sensor Supply

    Page 28 4.4.2. VOLTAGE SELECTION SENSOR SUPPLY For Intrinsically Safe applications: read chapter 5. Type PB / PC / PX (AP) - battery powered and output loop-powered applications: Terminal 11 provides a limited supply voltage of 3.2 V DC (coil signals 1.2V) for the signal output of the flowmeter.
  • Page 29: Terminal Connectors

    ◊ ◊ PD 8-30V DC 8,2-12-24V max 50mA ◊ ◊ Φ ◊ = standard =option Note - Option PM: Important: for Model F127-P-EL-TA, option PM (80-230V AC power supply) is not available. For Intrinsically Safe applications: read chapter 5. HF127PEN_EL_TA_v0501_04...
  • Page 30 Page 30 Terminal 07-08 power supply - output loop powered: Connect an external power supply of 8-24 volts AC or 8-30V DC to these terminals or a 4-20mA loop. For a DC supply: connect the “-“ to terminal 7 and the “+” to terminal 8. When power is applied to these terminals, the (optional) internal battery will be disabled / enabled automatically to extend the battery life time.
  • Page 31 Page 31 Option AI: An isolated 4-20mA signal proportional to the flowrate is available with this option. When the output is disabled, a 3.5mA signal will be generated on these terminals. Max. driving capacity 1000 Ohm @ 30V DC. This option can be battery powered but the life time of the battery is about 2 -3 years. Option AU: A 0-10V DC signal proportional to the flowrate is available with this option.
  • Page 32 Page 32 Pulse-signal NPN / NPN-LP: The F127-P-EL is suitable for use with flowmeters which have a NPN output signal. For reliable pulse detection, the pulse amplitude has to go below 1.2V. Signal setting NPN-LP employs a low- pass signal noise filter, which limits the maximum input frequency - read par. 3.2.3. Pulse-signal PNP / PNP-LP: The F127-P-EL is suitable for use with flowmeters which have a PNP output signal.
  • Page 33 Page 33 Active signals 8.1V - 12V and 24V: If a sensor gives an active signal, please read par. 3.2.3. The detection levels are 50% of the selected supply voltage; approximately 4V (ACT_8.1) or 6V (ACT_12) or 12V (ACT_24). Active signal selection may well be desired in the case of options PD-PM being supplied for sensor supply.
  • Page 34 Page 34 Terminal 12-14; Flowmeter input B: Exactly as described for the flowmeter A, three basic types of flowmeter signals can be connected for flowmeter input B. Please refer to the descriptions per flowmeter type as describer for flowmeter A. The 9-10-11 do correspond with the terminals 12-13-14. Terminal 17-19;...
  • Page 35: Intrinsically Safe Applications

    Please Note  Certificates, safety values and declaration of compliance can be found in the document named: “Fluidwell F1..-..-XI - Documentation for Intrinsic Safety”.  Special conditions for safe use mentioned in both the certificate and the installation instructions must be observed for the connection of power to both input and / or output circuits.
  • Page 36: Terminal Connectors Intrinsically Safe Applications

    Indicated labels on the back cover (below) and on the inside cover (right) show the type labels for intrinsically safe certified units. For details on usage see the separate “Fluidwell F1..-..-XI Documentation for Intrinsic Safety”. Serial number and year of production This information can be looked-up on the display: See setup function (par.
  • Page 37 Page 37 Explanation Intrinsically Safe options: Option AF - Intrinsically Safe floating 4-20mA analog output: A floating 4-20mA signal proportional to the flowrate is available with this option. When the output is disabled, a 3.5mA signal will be generated. Max. driving capacity 1000 Ohm @ 30V DC. Option PD - Intrinsically Safe power supply and sensor supply - Terminal GND- 01, 11 and 14.
  • Page 38: Configuration Examples

    Page 38 CONFIGURATION EXAMPLES Configuration example IIB/IIIC F127-P-AF-CT-EL-PD-TA-XI HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS F100-series Modbus communication type CT: TTL I.S. Certified  Isolator TTL to: = max. 30 V e.g. PC RS232 = max. 250 mA RS422 = max. 0.85 W +12V For example: Common ground...
  • Page 39 Page 39 Configuration example IIB/IIIC and IIC - F127-P-AF-CT-EL-PD-TA-XI HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS F100-series Modbus communication type CT: TTL Please note: communciation type CT is allowed in IIC applications. I.S. Certified  Isolator TTL to: = max. 30 V e.g.
  • Page 40: Battery Replacement Instructions

    Batteries for use in safe areas have no Ex label. DO NOT EXCHANGE: Using the wrong type of battery can pose a SERIOUS RISK.  For use in hazardous areas Fluidwell recommends FW-LiBAT batteries (manufactured by Fluidwell bv) only. Battery replacement procedure Depending on the production batch, one of two visualized Intrinsically Safe certified battery types may have been installed in the unit.
  • Page 41: Maintenance

    Page 41 MAINTENANCE 6.1. GENERAL DIRECTIONS  Mounting, electrical installation, start-up and maintenance of the instrument may only be carried out by trained personnel authorized by the operator of the facility. Personnel must read and understand this Operating Manual before carrying out its instructions. ...
  • Page 42: Appendix A: Technical Specification

    Page 42 APPENDIX A: TECHNICAL SPECIFICATION GENERAL Display Type High intensity reflective numeric and alphanumeric LCD, UV-resistant. Digits Seven 17mm (0.67") and eleven 8mm (0.31"). Various symbols and measuring units. Refresh rate User definable: 8 times/sec - 30 secs. Type ZB Transflective LCD with green LED backlight.
  • Page 43 Page 43 Sensor excitation Type PB / PC / PX 3.2V DC for pulse signals and 1.2V DC for coil pick-up. Note: This is not a real sensor supply. Only suitable for pulse sensors with a very low power consumption like coils (sine wave) and reed-switches. Type PD 1.2 - 3.2 - 8.2 - 12 and 24V DC - max.
  • Page 44 Page 44 OUTPUTS Analog output Type 4-20mA - passive output - not isolated. Resolution 10-bit. Accuracy < 0.05% - update 10 times a second. Software function to calibrate the 4.00mA and 20.00mA levels precisely within set-up. Load max. 1 kOhm Function transmitting flowrate.
  • Page 45: Appendix B: Problem Solving

    Page 45 APPENDIX B: PROBLEM SOLVING In this appendix, several problems are included that can occur when the F127-P-EL is going to be installed or while it is in operation. Flowmeter does not generate pulses: Check:  Signal selection SETUP - 71 / 72, ...
  • Page 46: Appendix C: Communication Variables

    Page 46 APPENDIX C: COMMUNICATION VARIABLES CONFIGURATION VARIABLES F127-P-TA - SETUP-LEVEL: DESCRIPTION BYTES VALUE REMARKS TOTAL A unit (20h) 1=m3 2=kg 3=lb 4=gal 5=usgal 6=bbl 7=none decimals 0…3 (21h) K-factor 1..9.999.999 K-f 0000001 - K-f 0000009 is (22h) allowed when decs < 6! (VAR37) decimals K-factor 0…6 (25h)
  • Page 47 Page 47 DESCRIPTION BYTES VALUE REMARKS TOTAL B K-factor 1..9.999.999 K-f 0000001 - K-f 0000009 is (28h) allowed when decs < 6! (VAR43) decimals K-factor 0…6 (2Bh) FLOWRATE B K-factor 1..9.999.999 K-f 0000001 - K-f 0000009 is (E3h) allowed when decs < 6! (VAR230) decimals K-factor 0…6 (E6h)
  • Page 48 Page 48 DESCRIPTION BYTES VALUE REMARKS TEMPERATURE A span 1..9,999,999 (212h) decimals span 0…6 (215h) offset 0.00..99,999.99 step: 0.01 K (216h) calibration low 0=default (4mA) 1=calibrate 2=cal set calibration high 0=default (20mA) 1=calibrate 2=cal set filter 0….99 display 0= °C (210h) 1= °F 2= K...
  • Page 49 Page 49 OTHER F127-P VARIABLES FOR COMMUNICATION DIFFERENTIAL TOTAL - variable number 566 (236h) – 6 bytes READ TOTAL: The value of total read using RS communications might differ from the value that appears on the display. This is due to the fact that the display can only display up to seven digits (e.g.
  • Page 50: Index Of This Manual

    Fig. 7: Grounding aluminum enclosure with type PM 115-230V AC..........27 Fig. 8: Switch setting sensor supply voltage..................28 Fig. 9: Overview of terminal connectors standard configuration F127-P-EL-TA and options.... 29 Fig. 10: Overview terminal connectors communication option............34 Fig.
  • Page 51 Page 51 LIST OF CONFIGURATION SETTINGS SETTING DEFAULT DATE : DATE : 1 - TOTAL - A Enter your settings here 11 unit 12 decimals 0000000 13 K-factor 0000001 14 decimals K-factor 2 - FLOWRATE - A 21 unit 22 time unit /min 23 decimals 0000000...
  • Page 52 D - OTHERS D4 pass code 0000 D5 tagnumber 0000000 Fluidwell bv HF127PEN_EL_TA_v0501_04 PO box 6 Voltaweg 23 Website: www.fluidwell.com 5460 AA Veghel 5466 AZ Veghel Find your nearest representative: www.fluidwell.com/representatives The Netherlands The Netherlands Copyright Fluidwell bv - 2012 - HF110AEN_v0501_03...