LOCATION OF STOVE

In order to achieve maximum circulation of heat produced by the stove, it is
recommended that the stove be centrally located. Remember that the heat will rise.
Therefore, if the stove is put next to a stairwell, much of the heat will rise to the second
floor before the ground floors are warm. One should consider the construction and layout
of the home to be heated and, therefore, make placement so as to achieve maximum
benefit from the stove.

CHIMNEY CONSTRUCTION AND MAINTENANCE

A good chimney is essential. This unit must be connected to either a listed type
HT (2100°F) chimney per UL 103 or ULC S629 or a code approved masonry chimney
with flue liner. The chimney size should not be less than the flue outlet on the stove, or
more than 3 times greater than the cross sectional area of the flue. Should you intend to
use an existing chimney for your stove, make sure that it is sound and has a flue lining
free from defects and corrosion. A chimney sweep should be consulted to assure there is
no existing creosote or soot build up present. Should the chimney lack flue tiles or if the
masonry is cracked, consult a mason about repairs or line the flue with a stainless steel
flue liner. Fire in an unlined or cracked chimney can spread into the house. The top of
the chimney should be at least 3 feet higher than the roof at the point of exit. With
pitched roofs, the top of the chimney must be at least 2 feet higher than any point on the
roof within 10 feet of the chimney. Check with your local building inspectors for local
building code compliances. The ideal installation would be for the chimney to extend
below the thimble with a clean out door.
The use of aluminum Type B gas vent for solid fuels in unsafe and prohibited by
the National Fire Protection Association Code.
Your chimney and chimney connectors should be inspected at least twice monthly
during the heating season to determine if a creosote or soot build up has occurred. If
material has accumulated, it should be removed to reduce the risk of a chimney fire.
Your chimney should be cleaned at least once a year. REMEMBER, a clean chimney
and a controlled fire will eliminate almost any chance of a chimney fire. Above all,
REMEMBER, if a chimney fire does occur, the fire department should be called
immediately and the draft control on the stove closed. DO NOT TAKE CHANCES BY
LETTING THE CHIMNEY BURN ITSELF OUT.
INSTRUCTIONS
MODEL EZ-FLO 50-93
MODEL EZ-FLO 30.95
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EZ-FLO 50-93 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hitzer EZ-FLO 50-93

  • Page 1 Page 1 INSTRUCTIONS MODEL EZ-FLO 50-93 MODEL EZ-FLO 30.95 LOCATION OF STOVE In order to achieve maximum circulation of heat produced by the stove, it is recommended that the stove be centrally located. Remember that the heat will rise. Therefore, if the stove is put next to a stairwell, much of the heat will rise to the second floor before the ground floors are warm.
  • Page 2 Page 2 INSTALLATION OF STOVE CAUTION: DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE. WARNING: THE INSTALLATION OF THESE STOVES MUST COMPLY WITH STATE AND LOCAL REQUIREMENTS AND BE INSPECTED BY THE STATE OR LOCAL INSPECTOR IF REQUIRED. NOTE: These stoves are not approved for use in mobile homes.
  • Page 3 Page 3 fastened piping may come apart causing an extreme fire and smoke hazard. Assure that the chimney connections pipe extend at least 2 inches into the chimney, but does not extend so far into the chimney flue that it blocks air flow. Where the pipe connects to a masonry chimney, it must be cemented to the chimney, or a thimble must be connected to the chimney and the pipe should be tightly inserted into the thimble without cement.
  • Page 4 Page 4 type of appliance you burn it in. Carbon monoxide is produced when burning gas, oil, wood, coal, and anything else that burns and any venting problems can cause it to back up into the house. Carbon monoxide is extremely dangerous and can result in serious injury or even death Starting your fire with anthracite coal: To start your E-Z Flo open up the automatic damper on the rear of your stove to...
  • Page 5 Blowers: If your unit is equipped with blowers should be cleaned of dust and dirt periodically. Replace only with original blower available from your Hitzer dealer. CAUTION: ALWAYS DISCONNECT UNIT FROM POWER SOURCE BEFORE ATTEMPTING TO SERVICE OR REPLACE ANY ELECTRICAL SYSTEM...
  • Page 6 Never clean glass with harsh abrasives. Replace glass only with ROBAX CERAMIC glass (30-95 5mm x 9” x 15 9/16”, 50-93 5mm x 9” x 17 7/16”) available from your Hitzer dealer. Use of any other type of glass can cause glass to fail creating a fire hazard Should you be required to replace the glass first remove door from your stove and lay face down on a smooth solid surface.

This manual is also suitable for:

Ez-flo 30-95

Table of Contents