mains plug is plugged into the mains socket and that the
charger is ready to be used.
Continuously illuminated red battery charge level
indicator (3)
The continuous light of the red battery charge
level indicator (3) shows that the temperature
of the battery is outside of the permitted char-
ging temperature range, see section "Technical
data". The charging process begins as soon as the permitted
temperature range has been reached.
Flashing red battery charge level indicator (3)
The flashing light of the red battery charge
level indicator (3) signals that the charging
process has been interrupted by a different
fault, see section "Errors – causes and correct-
ive measures".
Indications on 36 V Batteries
During the charging procedure, the three green charge-con-
trol indicators (5) of the battery light up one after the other
and briefly go out. The battery is fully charged when the
three green indicators light up continuously. After approx.
5 minutes after the battery has been fully charged, the three
green indicators go out again.
When the red temperature control indicator (6) lights up
when placing the battery into the charger, the temperature
of the battery is not within the charge-temperature range
(see section "Technical Data"). The battery cannot be
charged until after the allowable operating temperature
range has been reached.
Errors – causes and corrective measures
Cause
Corrective measures
Red battery charge level indicator (3) is flashing
Charging not possible
The battery is not connected
Connect battery to charger
(correctly)
correctly
Battery contacts are dirty
Clean the battery contacts;
e.g. by connecting and dis-
connecting the battery sev-
eral times. Replace battery if
necessary
Battery defective
Replace the battery
Green battery charge level indicator (2)or (3) is not illu-
minated
Mains plug of the charger is
Insert the mains plug (fully)
not (correctly) plugged in
into the plug socket
Plug socket, mains cable or
Check mains voltage, have
charger defective
charger checked if necessary
by an authorised after-sales
service centre for Bosch
power tools
Bosch Power Tools
Practical advice
When the charger is used continuously, or for several con-
secutive charge cycles without interruption, the charger may
heat up. This is, however, harmless and does not indicate
that the charger has a technical defect.
A significantly reduced operating time after charging indic-
ates that the battery has deteriorated and must be replaced.
Battery cooling (Active Air Cooling)
The fan control unit integrated into the charger monitors the
temperature of the inserted battery. As soon as the battery
temperature is above approx. 0 °C, the battery will be cooled
by a fan. The fan generates a ventilation sound when
switched on.
If the fan does not run, it is defective or the battery temper-
ature is < 0 °C. This can increase the charging time.
Maintenance and Service
Maintenance and cleaning
In order to avoid safety hazards, if the power supply cord
needs to be replaced, this must be done by Bosch or by an
after-sales service centre that is authorised to repair Bosch
power tools.
After-Sales Service and Application Service
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. You can find explosion drawings and information on
spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you
with any questions about our products and their accessor-
ies.
In all correspondence and spare parts orders, please always
include the 10‑digit article number given on the nameplate
of the product.
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169
Customer Contact Center
Inside Australia:
Phone: (01300) 307044
Fax: (01300) 307045
Inside New Zealand:
Phone: (0800) 543353
Fax: (0800) 428570
Outside AU and NZ:
Phone: +61 3 95415555
www.bosch-pt.com.au
www.bosch-pt.co.nz
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
English | 9
1 609 92A 5F8 | (22.10.2019)

Advertisement

Table of Contents
loading

Table of Contents