14V ~ and that the switched current will not be higher than 2 A ~. The door phone has only be licensed for its intended use. AGFEO GmbH will not be liable for any damage if the door phone is used other then for its intended use.
Change Operation of 12 V Output ....................16 Technical Data ..........................16 Confirmation Tones ........................16 Declaration of Confirmity for TFE 2 ....................17 Declaration of Confirmity for TFE 4 ....................18 Declaration of Confirmity for Power Supply ................. 19...
Please contact your Dealer for connections to AGFEO Systems which do not support the operation mode “Door”. The AGFEO TFE 2 can be fitted with 1 or 2 bell push buttons. In addition there is a 12 V contact and a potential free relay contact.
1 Allen Key Fitting instructions The Door Phones TFE 2 and TFE 4 are suitable for surface or flush mounting. In addition the TFE 2 may be installed upright or horizontally. The bell push module can be turned by 90...
Page 6
Before the installation of the door phone you may want to decide if you want to fit the module upright or horizontally. This is only applicable to the modules with one or two bell push buttons. The module with three or four buttons can only be installed upright. Various fitting possibilities for the TFE 2 Button1 Button2...
TFE 2, TFE 4 Location of Unit The door phone TFE 2 and TFE 4 have been designed for use outside and are protected from water splashes (Dampness protection to IP 53, water splashes of an angle of 60º from vertically) Please select the location of the unit so that there is a minimum distance of 10 cm ( 4 inches ) from the microphone to the nearest wall.
TFE 2, TFE 4 Flush Mounted Fitting The wall cut out should fit the measurements of the flush mounted housing. (Observe minimum distance and location of installation) Please make sure that there are no mains services buried in the wall. Measurements for the cut out to be L x H x D approx. 220 x 90 x 50 mm.
Page 9
TFE 2, TFE 4 Loosen Door Phone from Flush Mounted Housing Unscrew both screws with the Allen Key provided from underneath the cover. Remove Door Phone from Flush Mounted Housing To release the unit use a medium sized screw driver or Allen Key and press the bottom latch then pull off the door phone with an upward movement.
TFE 2, TFE 4 Surface Mounting Fit the surface mount frame either upright or horizontally as required. (Observe minimum distance) Before drilling ensure that there are no life wires or other main services. Fix the frame using the wall plugs supplied and screw this to the wall Connection of Door Phone to System Install cable to the telephone system and door opener.
TFE 2, TFE 4 Name Plate Remove the cover of the name plate by using a medium size screw driver inserting this into the cut out on either the left or right hand side and carefully moving this upwards. Write on the name plate using a waterproof pen and insert the label in the recess of the bell push.
TFE 2, TFE 4 Telephone System Configuration After you have connected the door phone to the telephone system you will have to read out the system configuration. Assign in the section “Devices: Analogue / Analogue System Phones” an extension number to which the door phone is connected. Also select the “Phone Type” to “Door”.
TFE 2, TFE 4 Programming the Door Phone In order to make changes to the door phone setting, the door phone extension must be called from a DTMF telephone. Programming can begin as soon as a connection has been established to the door phone.
Confirmation Tone Calibrate Door Phone In order to guarantee an optimal speech quality with AGFEO Telephone Systems the door phone TFE2 and TFE4 can automatically adjust to the relevant telephone system used . With the Procedure #*00 the calibration process will be started. A test tone will be played during which the Talk LED will blink intermittently.
You may connect a door bell either to the 12 V output contact or potential free relay contact of the TFE 2 door phone only. To operate a door bell on the potential free relay contact you will need additional power for the supply to the door bell.
TFE 2, TFE 4 Change Operation of 12 V Output hzq##qzq Enter Programming Mode: 1= external Bell 0 = Door Opener Select mode of Operation Positive Confirmation Tone Technical Data Operating Temperature Range: -25 Cº bis +55 Cº Storing Temperature: -25 Cº...
TFE 2, TFE 4 Declaration of Confirmity for Power Supply...
Page 20
Ident. no. 1100925 Subject to change without notice. No liability can be AGFEO GmbH & Co. KG accepted for errors contained in Gaswerkstr. 8 this document.