Summary of Contents for AGFEO TFE 2

  • Page 1 Installation Manual Door Phone TFE 2, TFE 4...
  • Page 2: Safety Notice

    14V ~ and that the switched current will not be higher than 2 A ~. The door phone has only be licensed for its intended use. AGFEO GmbH will not be liable for any damage if the door phone is used other then for its intended use.
  • Page 3: Table Of Contents

    Allocation of Bell Push Buttons to Switched Output ..............17 Change Allocation .......................... 17 Technical Data ..........................18 Confirmation Tones ........................18 Declaration of Confirmity for TFE 2 ....................19 Declaration of Confirmity for TFE 4 ....................20 Declaration of Confirmity for Power Supply ................. 21...
  • Page 4: Introduction

    Please contact your Dealer for connections to AGFEO Systems which do not support the operation mode “Door”. The AGFEO TFE 2 can be fitted with 1 or 2 bell push buttons. In addition there is a 12 V contact and a potential free relay contact.
  • Page 5: Supplied Items

    1 Allen Key Installation Instructions The Door Phones TFE 2 and TFE 4 are suitable for surface or flush mounting. In addition the TFE 2 may be installed upright or horizontally. The bell push module can be turned by 90...
  • Page 6 This is only applicable to the modules with one or two bell push buttons. The module with three or four buttons can only be installed upright. It is important to pay attention to the button numbers for programming! Various fitting options for the TFE 2 Button1 Button2...
  • Page 7: Location Of Unit

    TFE 2, TFE 4 Location of Unit The door phone TFE 2 and TFE 4 have been designed for use outside and are protected from water splashes (Dampness protection to IP 53, water splashes of an angle of 60º from vertically) Please select the location of the unit so that there is a minimum distance of 10 cm ( 4 inches ) from the microphone to the nearest wall.
  • Page 8: Flush Mounted Fitting

    TFE 2, TFE 4 Flush Mounted Fitting The wall cut out should fit the measurements of the flush mounted housing. (Observe minimum distance and location of installation) Please make sure that there are no mains services buried in the wall. Measurements for the cut out to be L x H x D approx. 220 x 90 x 50 mm.
  • Page 9 TFE 2, TFE 4 Remove Door Phone from Flush Mounted Housing Unscrew both screws with the Allen Key provided from underneath the cover. Remove Door Phone from Flush Mounted Housing To release the unit use a medium sized screw driver or Allen Key and press the bottom latch then pull off the door phone with an upward movement.
  • Page 10: Surface Mounting

    TFE 2, TFE 4 Surface Mounting Fit the surface housing either upright or horizontally as required. (Observe minimum distance) Before drilling ensure that there are no life wires or other main services. Fix the housing using the wall plugs supplied and screw this to the...
  • Page 11: Installation Der Tfe

    TFE 2, TFE 4 Name Plate Remove the cover of the name plate by using a medium size screw driver inserting this into the cut out on either the left or right hand side and carefully moving this upwards. Write on the name plate using a waterproof pen and insert the label in the recess of the bell push.
  • Page 12: Basic Settings Telephone System Configuration

    The following will describe the basic configuration for AGFEO Telephone System „AS“ Series and the AGFEO AC 14 Analogue. After connection of the doorphone to your telephone system download the configuraton of your telephone system. Allocate an extension number to the port to which the doorphone is connected and set the type of device to „Door“in the section „System...
  • Page 13: Doorphone Setup

    This programming may be carried out consecutively after programming mode has been initiated. The allocation of bell push buttons can be found on page 6. As soon as extension numbers have been programmed the AGFEO TFE2/TFE4 is operational. The following pages will illustrate further programming possibilities.
  • Page 14: Additional Programming Doorphone Setup

    TFE 2, TFE 4 Additional Programming Doorphone Setup In order to make changes to the door phone setting, the door phone extension must be called from a DTMF telephone. Programming can begin as soon as a connection has been established to the door phone.
  • Page 15: Ringing Duration To Extension

    Confirmation Tone Door Phone Calibration In order to guarantee an optimal speech quality with AGFEO Telephone Systems the door phone TFE2 and TFE4 can automatically adjust to the relevant telephone system used . With the Procedure #*00 the calibration process will be started. A test tone will be played during which the Talk LED will blink intermittently.
  • Page 16: Microphone Sensitivity Speaker Volume

    TFE 2, TFE 4 Microphone Sensitivity Speaker Volume You may adjust the microphone sensitivity and speaker volume. The sensitivity of the microphone can be set in a range 4 steps, the speaker has a setting range of 32 steps. hzq##qzq Enter Programming Mode: Press the digit 2 to decrease the microphone sensitivity by one step.
  • Page 17: Connecting Additional Door Bells

    TFE 2, TFE 4 Connecting Additional Door Bells You may connect an additional doorbells to each of the dry switched contact or the 12 V output of the doorphone. To connect a door bell to the dry switched contact you must feed a supply voltage to the doorphone and the door bell.
  • Page 18: Technical Data

    TFE 2, TFE 4 Technical Data Operating Temperature Range: -25 Cº bis +55 Cº Storing Temperature: -25 Cº bis +70 Cº Transport Temperature: -25 Cº bis +70 Cº Door Phone Cover: 104 x 234 x 17 mm Surface Mount Frame:...
  • Page 19: Declaration Of Confirmity For Tfe 2

    TFE 2, TFE 4 Declaration of Confirmity for TFE 2...
  • Page 20: Declaration Of Confirmity For Tfe 4

    TFE 2, TFE 4 Declaration of Confirmity for TFE 4...
  • Page 21: Declaration Of Confirmity For Power Supply

    TFE 2, TFE 4 Declaration of Confirmity for Power Supply...
  • Page 24 Ident. no. 1100925 Subject to change without notice. No liability can be AGFEO GmbH & Co. KG accepted for errors contained in Gaswerkstr. 8 this document.