Requirements for Compliance with UL294 6th Edition
This section contains information and instructions required
for UL compliance. To make sure the installation is UL
compliant, follow the instructions below in addition to the
general information and instructions provided throughout
this document. In cases where pieces of information
contradict each other, the requirements for UL compliance
always replace general information and instructions.
Performance Levels for Access Control
This section contains performance level information
required for UL 294 compliance.
Feature
Destructive Attack Test
Line Security
Endurance
Standby Power
Safety Instructions
The Axis product shall be installed and serviced by a
factory trained professional.
The Axis product shall be installed within the protected
premises (secured area).
The Axis product shall be mounted indoors. Outdoor
use has not been evaluated or approved by UL.
All interconnecting devices shall be UL Listed and Class
2 low-voltage power limited.
All wiring methods shall be performed in accordance
with NFPA70, local codes and authorities having
jurisdiction.
When the Axis product has reached the end of its
useful life, dispose of it according to local laws and
regulations. The product should not be disposed of
together with household or commercial waste. See
Disposal and recycling on page 3 .
Battery
-
-
-
Level
I
I
IV
I
The 3.0 V lithium battery used by
the Axis product is a UL Recognized
component. (Type: BR2032,
diameter: 20 mm (0.78 in),
manufacturers: Rayovac,
Panasonic). The following battery
type is also a UL Recognized
component: Type CR2032,
manufacturers: Fuji, Maxell,
Renata, Varta, Panasonic, JHIH
Users shall not replace the battery.
If the battery needs replacing, a
factory trained service professional
shall contact Axis support
at www.axis.com/techsup for
assistance.
Used batteries shall be disposed
of according to local laws and
regulations, which may vary from
state to state. Waste BR/CR
lithium cells are neither listed
nor exempted from the USEPA
hazardous waste regulations. Waste
lithium batteries can be considered
reactive hazardous waste if there is
Specifications
Operating Conditions
-
-
-
Wire area
-
-
Connectors
-
-
-
-
-
-
System Considerations
-
Wall and Ceiling Mount
a significant amount of unreacted,
or unconsumed lithium remaining.
For information about how to
dispose of used lithium batteries,
contact your local authority for
waste disposal.
Classification IEC 60721-4-3 Class
3M3
Temperatures
-35°C to 66°C (31 °F to 150.8 °F).
Humidity 20–85% RH (non-
condensing)
UL Listed or R/C AWM wires that
have an conductor gauge range of
AWG 22–14 shall be used.
The minimum conductor gauge for
connection between the power
sourcing equipment (PSE) or power
injector and the powered device
(PD) is 26 AWG.
This product is not intended for
outside wiring as covered by Article
800 in the National Electrical Code,
NFPA 70.
Power Connector – For UL security
applications, the product shall be
powered by a UL 294 Listed or
UL 603 Listed Class 2 low-voltage
power SELV and limited power
supply that is capable of 4 hours of
standby power.
External power to relays - If the
relays are connected to an external
power source this must be UL 294
Listed or UL 603 Listed Class 2
low-voltage power SELV and limited
power supply that is capable of 4
hours of standby power.
Network Connector – Power over
Ethernet (PoE) shall be supplied by a
UL 294 Listed Power over Ethernet
IEEE 802.3af/802.3at Type 1 Class
3 or Power over Ethernet Plus
(PoE+) IEEE 802.3at Type 2 Class 4
power limited injector that provides
44–57 V DC, 15.4 W / 30 W and 4
hours of standby power.
The products shall not be installed
in the fail-secure mode unless
permitted by the local authority
having jurisdiction.
Compliance with IEEE 802.3 (at or
af) specifications is not verified as
part of UL 294B.
Tampering Alarm Pin
Header – To comply with
UL 294/7.2.1 (Enclosure), the
tampering alarm shall be connected
to a sound alarm.
The Axis product shall not impair
the intended operation of the panic
hardware used in conjunction with
it.