Original operating instructions MSA400 Contents Correct use ...................................... 4 Safety notices ....................................5 Description of device and functions ............................... 6 Operating and display elements ..............................7 First operation ....................................8 Operation using operating push button ............................10 Programming ....................................13 Reset the sash position ..................................15 Cleaning and maintenance ................................16...
• Do not use the MSA400 system on emergency exit or panic exit doors. • Sliding elements that are equipped with the MSA400 slide drive must not be used as escape doors in the event of a fire. • Do not put the MSA400 into operation when it is not installed, as this can cause mechanical defects.
Connect in-wall supply lines to the MSA400 in branch boxes. These branch boxes must be kept accessible for maintenance. › When cleaning the sliding sash and the drives, make sure that no liquid gets inside the MSA400 system as this could damage the electronics. ›...
Description of device and functions The MSA400 system opens and locks the sliding element at the push of a button. The system can be operated using the operating push button on the drive, the supplied infrared remote control or an optional wall switch. Two separate program- ming buttons on the drive allow you to program the system.
Note: Wall buttons are not included in the standard scope of delivery. They are additional equipment that must be provided by the customer. If a wall button has been installed by the customer, the MSA400 system can also be operated using this wall button. 03.2015...
Original operating instructions First operation When operating the MSA400 system for the first time, you must perform a reference run and then a calibration/teach-in run. Perform reference run 1. The sliding sash must be in the CLOSED position in order to begin the reference run. If necessary, slide the sash to this position manually.
Page 9
During the entire calibration and teach-in run, maintain a safe distance from the moving elements. Risk due to incorrect measured values! › To prevent incorrect measured values, never interrupt or interfere with the calibration and teach-in run of the MSA400 system 1. Block sliding sash 2 (not applicable for scheme A).
› The sliding sash stops. Opening sliding sash to intermediate position Note: The desired intermediate position must be programmed on the MSA400 system before carrying out this function – see . “Teach in intermediate position” on 14. › With the sliding sash closed, press and hold the operating push button for approx. 2 seconds until a short acoustic signal sounds once.
Page 11
Original operating instructions MSA400 Closing the sliding sash (without locking) Note: This function must be programmed on the MSA400 before it is carried out – see “Teach in close function without locking” on 15. › With sliding sash open, press the operating push button once.
Page 12
MSA400 Original operating instructions Operation via the infrared remote control Important: When operating the system using the infrared remote control, always point the remote control in the direction of the LED. Intense solar radiation and light incidence can reduce the range of the infrared remote control.
Original operating instructions MSA400 Programming Infrared remote control Teach in group Important: The supplied infrared remote control is taught-in to group 1 by default. 1. Press the Prog button; the LED flashes green. 2. Press and hold the operating push button for approx. 5 seconds until a short acoustic signal sounds 2 times in succession.
Page 14
MSA400 Original operating instructions Special functions Teaching-in the intermediate position 1. Close sliding sash completely (CLOSED position). 2. Press the Prog button; the LED flashes green. 3. Press and hold the operating push button for approx. 8 seconds until a short acoustic signal sounds 3 times in succession.
Original operating instructions MSA400 Function Teaching-in close without locking 1. Open sliding sash completely (OPEN position). 2. Press the Prog button; the LED flashes green. 3. Press and hold the operating push button for approx. 5 seconds until a short acoustic signal sounds 2 times in succession.
In case of a malfunction, do not open the device or try to repair it under any circumstances. If the problem is not listed in the table below, please contact your window specialist or SIEGENIA directly: Tel. +49 271 3931-0...
Although our products do not fall within the scope of the German Electrical and Electronic Equipment Act (ElektroG), SIEGENIA will continue to meet the requirements of this Act and will endeavour to completely eliminate the use of substances that are hazardous to the environment as soon as this becomes technically feasible. Electrical products should not be disposed of as household waste.
Page 20
Switzerland Phone: +41 33 3461010 Germany Phone: +49 271 39310 Turkey Phone: +90 216 5934151 You can fi nd address details for our Great Britain Phone: +44 2476 622000 Ukraine Phone: +380 44 4637979 international sites at: www.siegenia.com Contact your dealer:...
Need help?
Do you have a question about the MSA400 and is the answer not in the manual?