C1250 CA PS TA N pacific s i m p s o n -l a w r e n ce in st a lla t io n , o per a t io n & m a in t en a n ce in st r u ct io n s contents ..........................
P AR TS 1.2.1 Identify your model E xploded Diagram Type List No. Tick 1.2.0 F or F uture R eference 12V P acific C 1250 Anchoring 0032010 After you have read this instruction booklet, please keep it safe on board your vessel for future reference. 24V P acific C 1250 Anchoring 0032020 1.2.2 P lease note your serial number and voltage.
PARTS LIST Item Part No. Part Description Quantity C1250 C1250 Anchoring Anchoring P103064 Shim Bearing - Main P103036 Shim Bearing - Gears P103037 Shim W asher - Drum P106003 Drum P106200 Cap - T op P106210 Cap - Inner Seal P106215 Cap - Lock P109003...
SPECIFICATION 5.1.6 Longer Studs For thicker than standard decks, simply fit longer studs as Performance Data: appropriate (Thread M8 x 1.25). Studs to special lengths may be obtained from Simpson-Lawrence Engineering Limited. Typical Working Figures (12V/24V) Warping 5.2.0 Wiring Load Speed Current Draw 110kg(220lb)
5.5.0 Wiring Diagrams 5.5.1 Single Direction Wiring (High Load Foot Switch Only) C1250 CAPSTAN High Load Foot Switch 0052516 Circuit Breaker/Isolator 70A-0050711-12v 50A-0050710-24v 12v/24v BATTERY Total Length Required = A + B + C + D Note: Reversing polarity will result in permanent damage to the capstan (see 5.2.1). ALL installations must be carried out in accordance with USCG, ABYC and NMMA requirements.
Page 7
5.5.2 Single Direction Wiring C1250 CAPSTAN High Load Foot Switch Deck Foot Switch 0052516 0052514 LEWP49C QU900/D LEWP49CW QU900/U Circuit Breaker/Isolator 70A-0050711-12v 50A-0050710-24v Inline Fuse 12v-5 AMP, 24v-3.15 AMP Single Direction Solenoid 0052505-12v 0052506-24v 12v/24v BATTERY Total Length Required = A + B + C + D Only one type of switch is required, though more than one may be fitted.
OPERATING INSTRUCTIONS Safety First! 6.2.3 Caution! Your Simpson-Lawrence Pacific capstan is a powerful piece of Should the capstan stall, switch off and wait a few seconds equipment and should be respected as such. Keep young before trying again. If the recommended breaker/isolator has children and observers, who are unfamiliar with anchoring tripped, it will require to be manually reset before the capstan procedures, away from the operating area when in use.
IMPORTANT USER INFORMATION MAINTENANCE Classification Societies require that a vessel lying to anchor General Recommendations should have its rode held by a chain stopper or equivalent Isolate the capstan electrically, before carrying out any strong point as capstans are not designed to withstand the maintenance work.
THREE YEAR LIMITED WARRANTY WARRANTY COVERAGE: SIMPSON-LAWRENCE LIMITED., warrants to the original purchaser, subject to the limitations and exclusions described below, that this product will be free from defects, in material and workmanship under normal use and service, for a period of three (3) years from the date of its original sale, except that the warranty shall be for a period of one (1) year for seals, electric motors, electrical equipment, electronic controls, composite gipsies and hydraulic pumps.
Page 11
The model described in this document is subject to a policy of continual improvement. Simpson-Lawrence Engineering Limited reserve the right to alter specifications and recommendations without notice. For the latest information regarding any aspect of your windlass please contact your local agent or Simpson-Lawrence Engineering Limited:-...
Page 12
Email info@simpson-lawrence.co.uk Service Division Telephone +44 (0)141 300 9200 +44 (0)141 427 9666 Facsimile +44 (0)141 427 5419 Simpson Lawrence USA Inc. 6208, 28th Street East Bradenton FLORIDA 34203-4123 United States of America. Telephone 1 800 WINDLAS (Toll Free) 1 800 946 3527...