5. Activation
Automatic
1/2 (blinking)
Standby
5.3

Switching of DuoCartSwitch

With the Firmware 9.26 / 11.10 / 17.06 there can be a
switching delay of maximum 10 minutes, before the
DuoCartSwitch switches into the correct position. The
switching from fuel cartridge 1 to fuel cartridge 2 will appear
in the terminal programme and on the display of the control
panel:
Example:
SFC>SFC
battery voltage 12.46V
output current 3.17A
operation time (charge mode) 1507.4h
operating state: auto on
operating mode: auto
cumulative output energy 135666.0Wh
no error
cartridge level above sensor or no sensor
(cartridge 1>2 consumed: 10 l / 2.64 US gal)
While switching from fuel cartridge 1 to fuel cartridge 2 the
number 2 blinks on the display of the control panel. The
number 2 remains permanently in the display after successful
switching to fuel cartridge 2.
If there is no fuel cartridge connected to the fuel connector 2,
the DuoCartSwitch switches back to fuel cartridge 1 and
checks, if there is methanol available. This procedure can
take up to 10 minutes.
The same procedure passes trough while switching form fuel
cartridge 2 to fuel cartridge 1.