Projecta INTELLI-RV PM100 Instruction Manual page 12

12v power management system
Table of Contents

Advertisement

Mains
Str Bat. Charge Fault
Troubleshooting
"FAULT" flashes once every sec.
Service battery low voltage alarm.
10V≤ Service battery voltage <10.5V.
No starter battery connected.
"FAULT" flashes once every sec.
"Starter Bat."flashes twice every sec.
Service battery low voltage alarm.
10V≤ Service battery voltage <10.5V.
Starter batter has been connected,
but VCR disconnect.
"FAULT" flashes twice every cycle.
Service battery high voltage alarm.
Service battery voltage≥16V.
No Starter battery connected.
"FAULT" flashes twice every cycle.
Service battery high voltage alarm.
Service battery voltage≥16V.
Starter batter has been connected.
"FAULT" flashes 3 times every cycle.
PM100 unit over temp alarm.
PM100 is working under PS mode.
"FAULT" flashes 3 times every cycle.
"Charge"flashes as 1 sec on then 2 sec off
PM100 unit over temp alarm.
PM100 is working under CHG mode.
"FAULT" flashes 4 times every cycle.
"Charge"flashes as 1 sec on then 2 sec off.
Bulk charging time out alarm.
"FAULT" flashes 5 times every cycle.
"Charge" flashes once every sec.
VCR anomaly alarm.
"FAULT" flashes 6 times every cycle.
Environment over temp alarm.
PM100 is working under PS mode.
"FAULT" flashes 6 times every cycle.
"Charge"flashes as 1 sec on then 2 sec off.
Environment over temp alarm.
PM100 is working under CH mode.
Description
The serivce battery needs to be charged
as soon as possible.
The serivce battery needs to be charged
as soon as possible.
Please consult the distributor,
installer or PROJECTA
Please consult the distributor,
installer or PROJECTA
PM100 will restart automatically
Check the ventilation and try to
disconnect some of the less priority loads.
If the fault still exists, please contact the
distributor, installer or PROJECTA
1. Check the setting of the battery capacity.
It should match the actual battery capacity.
2. Check the status of the battery.
If the battery is dead, please contact the
battery manufacturer or distributor.
Please consult the distributor,
installer or PROJECTA
PM100 will restart automatically.
PM100 will stop charging immediately.
12
Solutions