Setting the output action mode (for admin only)
Send from admin number the follow command:
OUTKEY [functionality] with functionality that can assume the values:
− RING it reacts as it does to a call when the key is pressed
− TOGGLE the key switches the output ON/OFF in bistable mode
− BLOCK disables the key functionality (it is not possible to access programming
mode when in this mode)
If the value is omitted, the current instrument status will be the response.
•
Enable/Disable caller number control (for admin only)
It is possible disable temporary the control of the caller number with the command:
RINGCONTROL [status]
with status that can assume the values:
− ON controls the caller number to check whether it is enabled
− OFF disable the control
If the value is omitted, the current instrument status will be the response.
•
Enable/Disable a caller response message (for admin only)
It is possible to send a text message confirming to the caller with the follow command:
RINGRISP [status] with status that can assume the values:
− ON sends a text message confirming activation to the caller
− OFF no confirmation text message to the caller
If the value is omitted, the current instrument status will be the response.
•
Setting the output mode after a ring (for admin only)
It is possible setting the output action mode in case of receive a ring from a certain
number with the command:
OUTRING [output status] [status permanence time] [time unit of measurement]
in which the parameters can assume the following values
− [output status] ON, OFF, TOGGLE, DISABLE
− [status permanence time] maximum (2
32
-1) seconds (optional parameter)
− [time unit of measurement] s seconds, m minutes, h hours (optional parameter)
Examples:
OUTRING ON
when ring, the output turn on
OUTRING OFF 10 S
the relay is turned OFF for 10 seconds when the call is received
Setting the output status (for admin only)
•
It is possible command the output with the command:
OUT [output status][status permanence time][time unit of measurement], where
− [output status] ON or OFF
− [status permanence time] maximum (2
32
-1) seconds (optional parameter)
− [time unit of measurement] s seconds, m minutes, h hours (optional parameter)
Example:
OUT OFF 10 S
output OFF for 10 second
•
Setting the sending of a caller response message (for admin only)
It is possible sending a response message to the caller with the command:
OUTRISP [status] with status that can assume the values:
− ON enables the sending of a text message in response to the caller
− OFF disables the sending of a text message in response to the caller
If the status is omitted, the response will be the current instrument status.
•
Displaying the output status and the settings
It is possible to receive a message with the actual configuration of the instrument with the
follow command:
OUTINFO
A possible answear could be the following:
OUT=ON OUTRING=ON 5 S OUTRISP=ON RINGRISP=OFF OUTKEY=TOGGLE
•
Changing the output name (for admin only)
It is possible rename the output of the instrument with the command:
OUTTXT [output label]
Example:
OUTTXT porta
assigns to the output the name porta
A string of a maximum of 10 characters with no spaces can be assigned as a
name. To restore the original name, just write OUTTXT NO. If an alternative
name is defined for the output, this name can be used instead of OUT1.
For example:
valvola ON 10 M active output (valvola) for 10 minutes
•
Enabling the forwarding function (for admin only)
It is possible to receive the unkown commands in a specified number.
The command is:
FORWARD [number]
Example:
FORwARD +393331234567
If not modified, the number that receive the unkown messages is the admin.
FORwARD OFF disabled this function.
The sms that are send from the instrument beginning with "Fw: ".
•
Password management (for admin only)
It is possible to change the protection password of the instrument, useful in case of command
with number not certified.
The command is:
PASS [new password] with new password with a maximum of 8 figures
Example:
PASS 11223344
•
Sms power fail alert (only Trillo-B) (only admin)
Trillo-B permits to the admin number to receive a sms if the power supply switch off or if the
battery charge is low.
The command is:
POWERFAIL [status] with status that can assume the state:
− ON send to admin a text message when the power supply switch on or off or low battery
− OFF disabled the function
The device will send to the admin number the follow messages:
ALARM: POwER=OFF means failure power supply
ALARM: POwER=ON means supply restoration
ALARM: BATTERY=LOw means low battery level
REFERENCE STANDARDS
Conformity to the EU directive:
1999/5/EC R&TTE
is declared in reference to the Harmonised Standards:
EN 60950-1
EN 301489-1, EN 301489-7