Download Print this page

Vemer TRILLO User Manual

Gsm communication interface

Advertisement

Quick Links

V3IS00501-013
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: info@vemer.it - web site: www.vemer.it
DIMENSIONS
72
SET
Out
ON
TRILLO
CONNECTION DIAGRAMS
Power supply
1
2
DEFAULT SETTING
Password
12345678
Relay output status
OFF
ADMIN number
Undefined
USER numbers
Not defined
Caller control
Active
Automatic call answer
Disabled
Response to sms commands
Active
Forward unknown sms
Active
Advise power fail (only Trillo-B)
Active
DEVICE STATUS
The status of the device is segnalated by the bicolor led
OFF:  system not fed
BLINKING RED:  sim not inserted or pin code in activity
FIXED RED:  GSM field insufficient
FIXED GREEN:  starting system/network research
BLINKING GREEN:  connected to GSM network
QUICKLY BLINKING GREEN:  arriving in command (ring or sms)
QUICKLY BLINKING RED:  programming mode active
BLINKING YELLOw  connected to gsm field but low level battery (Trillo-B only)
TRILLO
Mod.
TRILLO-B
The communication interfaces Trillo and Trillo-B gsm technology based permit the remote
control of the electic services by own mobile phone. The output relay canbe controlled by sending
a text message or by ringing from an enabled number, thus saving the cost of the text message.
Both the instruments offer the option of receiving a text message confirming activation.
Moreover, Trillo-B has a backup battery that permits to the instrument to operate for an hour in
the case of power fail.
SAFETY WARNINGS
60
During the installation and operation of the device observe the following instructions:
1) The device must be installed by a qualifi ed person
2) The device is aimed to be used in household premises and similar environments
3) Do not use the device for purposes other than indicated
4) The device must be installed in a electric closed panel well protected.
5) A two-pole disconnect device shall be provided as part of the building installation
6) A protection device against over-currents should be installed in the electrical system,
upstream of the device
7) When installing the device, carefully respect the wiring diagrams
8) Disconnect the device from the power supply before accessing to the terminals
9) Do not power or connect the instrument if any part of it is damaged
10) The use of a GSM device can cause interference with the functioning of electronic devices
non-screened from radiofrequency signals (electromedical devices, pacemakers, hearing
aids etc.)
11) In case of fault, do not service the device yourself but contact the after-sales service.
12) The device is aimed for use in place with over-voltage category III and pollution degree 2,
as per standards EN 61010-1.
Code
VE245700
VE293700
TECHNICAL CHARACTERISTICS
Power supply:
− TRILLO: 230V ac (-10% ÷ +10%) 50Hz
− TRILLO-B: 15÷40V dc / 11÷28V ac 50Hz
Consumption:
− TRILLO: 30mA max
− TRILLO-B: 100mA max
7
8
9
Connection:
− cables with max 6 mm
Output
− a bistable relay with exchange contact
− breaking capacity: 8(5)A / 250V ac
− red led for signal output status
OUT
Signalling device status:
8 A / 250 V ~
− multicolour green/red led (only Trillo)
− multicolour green/red/yellow led (only Trillo-B)
GSM Dual Band module (900-1800 MHz)
SMA-F connector for external aerial (included in the box)
You can store up to 100 numbers
Operating temperature: 0 ÷ 50 °C
Operating humidity: 10 ÷ 90% noncondensing
Storage temperature: -10 ÷ +65°C
Protection: IP40
Insulation class: II
Container: 4 DIN modules
Backup battery capacity: about 1 hour (Trillo-B only)
INSTALLATION
In order for the instrument to operate, a sim card enabled for telephone traffic needs to be
inserted in the relative slot, with the pin code and the answerphone deactivated.
To insert the sim card, remove the cover and use a sharp object to press the slot release
mechanism, as illustrated in the alongside:
:
Attention. Ensure that the power cables are disconnected before inserting/remove
the sim card.
Once it has been connected, the instrument will become fully operative within around 30
seconds, during which the instrument status LED will be a fixed green colour (the time needed
to search for the network and initialise the instrument may vary on the basis of the GSM field
in which the instrument is installed and the provider used).
Once the initialisation phase is completed, the green LED will start to flash with a frequency of
1Hz and the instrument will be ready to receive commands via text message or a ring on the
telephone.
Note. If the device will be installed into a screened panel, it is possible to replace
the antenna included in the kit with an another one with 3 meters cable.
The longer antenna is available as optional. Ensure that the power cables are
disconnected before replace the antenna.

User manual

GSM COMMUNICATION INTERFACE
Read all instructions carefully
Model
Description
Trillo
GSM communication interface
Trillo-B
GSM communication interface with backup battery
2
section
OPERATION
TURN ON/OFF INSTRUMENT (only Trillo-B)
Trillo-B can be turn off without unlink the power cables simply pressing for at least 10
seconds for the key "Set" while all leds turn off. During the pression of the key, the output
led blinks quickly and the led
blinks green (or yellow) for the first 5 seconds and green/
red for the other 5 seconds.
To turn on the instrument, press the key "Set".
RESET THE DEVICE
The reset cancels all data and the parameters saved and restore the default parameters (see
the relative box).
To do a reset, proceed as follow:
Trillo
Switch on the instrument and press the key "Set" shortly in 3 seconds. The led relative to
the output will blink for few seconds.
Trillo-B
Switch on the instrument and wait that the output led turn off. Then press the key "Set"
shortly in 3 seconds. The led relative to the output will blink for few seconds.
SET THE CERTIFIED NUMBERS
In order to use the instrument, it is necessary to begin by setting the admin number
and the users number enabled (if any). Pressing the key "Set" for a long time (at least 5
seconds) allows you to enter the programming mode, where you can enable/disable the
various telephone services.
Setting the admin number
After switching the instrument on and after esch reset, for the first time and having
entered programming mode, the first telephone number that makes a call will
automatically be configured as the admin number. The admin number can be changed
later on by sending a text message from the current admin number with the command:
ADMIN [new admin number] (the new admin number must be in international format
+39...)
Nota. If you lose the admin number, it can only be changed by forcing an
instrument reset. To retrieve automatically all the user numbers, see the
section "Sim management".
Setting the user number (for admin only)
The user numbers can be entered/removed simply via a telephone call when the
instrument is in programming mode. The caller's number will be entered/removed on the
basis of whether it is respectively not present/present in the phone book. A confirmation
text message will be sent to the caller, indicating the number of locations occupied out of
the total number available. Alternatively, the user numbers can be added or removed by
sending a text message from the admin number with the commands:
USERADD [list of numbers to be added]
USERDEL [list of numbers to be removed]
The numbers to be added must be in international format +39... and separated by an
empty space between each number.
Sim card managment (for admin only)
The certified numbers are saved in the device memory. For this, in case of reset, these
numbers will be lose. To avoid to enter again all users numbers it is possible to create a
backup copy in the sim card, using the follow commands:
STORE
copy in sim card all the number saved in the device
RESTORE
restore only the numbers saved with the command STORE
For this, we raccomand you to do a STORE when all numbers are abilitated.
COMMANDS
It is possible to work on the output as follows:
− with the key present on the front panel
− with ring from a certified number
− with a sms from a certified number (without password) or not certified number (with
password)
Sms syntax
The structure for all the commands is:
[password] [separator] [command] [separator] [parameter1] [separator]..[parameterN]
where:
[password]  numerical field of a maximum of 8 figures
[separator]  comprised of one or more space characters
[command]  command recognised by the device
[parameter..]  series of parameters relative to the command
Password can be omitted if the command is imparted from a certified number
(admin or user).
Some commands can be give from the admin number only.
Several commands may be included in one text message. In this case, the commands
executed will only be those whose response is contained in a standard message (160
characters). To enter numbers with the decimal separator, you need to use a full stop.
The structure of a response to a command is similar to the command itself, with the
addition of the "=" symbol to indicate the current status. For example:
OUTKEY BLOCK  OUTKEY=BLOCK
Key function
If press shortly, the key permits to command the output relay. The admin number can set
the output action.

Advertisement

loading

Summary of Contents for Vemer TRILLO

  • Page 1: User Manual

    Both the instruments offer the option of receiving a text message confirming activation. the relative box). DIMENSIONS Moreover, Trillo-B has a backup battery that permits to the instrument to operate for an hour in To do a reset, proceed as follow: the case of power fail.
  • Page 2 • Sms power fail alert (only Trillo-B) (only admin) Trillo-B permits to the admin number to receive a sms if the power supply switch off or if the RINGRISP [status] with status that can assume the values: battery charge is low.

This manual is also suitable for:

Trillo-b