Example Configurations - IDENTEC SOLUTIONS i-MARK 2 Installation And Hardware Manual

Hide thumbs Also See for i-MARK 2:
Table of Contents

Advertisement

8.5 Example Configurations

Marker Loops at Gates
Several loops in close proximity to each other
All i-MARKs connected via i-BUS
Tags pass through marker loops, they don't remain in them
The standard setting will be:
Adjust the size of the inductive loop field with the loop current
Give every i-MARK a unique Loop ID
Leave Operation mode to "Continuous"
Set transmission slots unique for each loop in proximity
Set only the first device on the i-BUS to Master Mode
The example shows a setting for 2 adjacent marker loops. This i-MARK is set to use only the odd slot
numbers. The second loop is be set to use the even slot number.