Data Concentrator TELEM-GW6
User Manual
Martem AS
2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TELEM-GW6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Martem TELEM-GW6

  • Page 1 Data Concentrator TELEM-GW6 User Manual Martem AS 2010...
  • Page 2: Table Of Contents

    Contents 1. MAIN TASKS 2. POSSIBLE APPLICATIONS 3. FEATURES 4. VIEW 5. TECHNICAL DATA 6. TYPICAL APPLICATION FOR ELECTRIC POWER STATION 7. SWITCHES 8. INDICATION 9. FIRMWARE UPDATE 10. GW6 CONFIGURATION TOOL 10.1 Getting Started 10.2 GW6 Configuration Window 10.3 Tab Cards in the Configuration Window 10.3.1 Ports Tab Card 10.3.2 Devices Tab Card 10.3.3 Objects Tab Card...
  • Page 3: Main Tasks

    AS Martem Data Concentrator TELEM-GW6 User Manual 1. Main Tasks The tasks of the Data Concentrator Telem-GW6 (GW6) include the following: • To control and monitor the system from the control center using data communication protocols IEC 60870-5-101 and IEC 60870-5-104 •...
  • Page 4: View

    AS Martem Data Concentrator TELEM-GW6 User Manual 4. View Figure 4 Telem-GW6 view 5. Technical Data Data communication protocols • To higher or lower level systems IEC 60870-5-101 or IEC 60870-5-104 • To lower level devices IEC 61850, IEC 60870-5-103, IEC 60870-5-101...
  • Page 5 AS Martem Data Concentrator TELEM-GW6 User Manual Communication ports Communication ports may be freely configured for upper or lower level communication Built-in • 1x Ethernet connection with RJ45 connector • 1x RS-232 full modem serial connection with RJ45 connector • 1x RS-422 serial connection with RJ45 connector •...
  • Page 6: Typical Application For Electric Power Station

    AS Martem Data Concentrator TELEM-GW6 User Manual 6. Typical Application for Electric Power Station 7. Switches 1 – Reset: Switch RESET to ON state and then back to OFF state for Reset operation 2 – Dft. Set: To apply default setup: 1.
  • Page 7: Firmware Update

    Updating firmware: 1. Connect Secure Digital (SD) Memory Card to your computer 2. Extract the compressed firmware update file (provided by Martem AS) to your SD Memory Card 3. Disconnect the card from your computer 4. Insert the card to Telem-GW6 SD Memory Card slot * SD Memory Card slot is located at the back of the device 5.
  • Page 8: Gw6 Configuration Tool

    AS Martem Data Concentrator TELEM-GW6 User Manual 10. GW6 Configuration Tool 10.1 Getting Started When starting the GW6 configuration program, user interface window with the main menu is opened: Figure 10. 1.1 User interface window The following parameters are shown for information: Port –...
  • Page 9: Gw6 Configuration Window

    AS Martem Data Concentrator TELEM-GW6 User Manual Fields in the communication parameters window • Port – PC communication port which is used to communicate with GW6 • Baud rate – Data communication rate • Parity – Use of parity control bit Flow control –...
  • Page 10: Tab Cards In The Configuration Window

    AS Martem Data Concentrator TELEM-GW6 User Manual Table of configuration window menu items Main menu File Common View Help Read New (Ctrl+N) Basic Help (F1) Configuration Write Open(Ctrl+O) Advanced About Configuration Cancel Active Save (Ctrl+S) Transfer Save As Send Reset...
  • Page 11: Ports Tab Card

    AS Martem Data Concentrator TELEM-GW6 User Manual 10.3.1 Ports Tab Card Ports/configuration tab card (Figure 10.3.1) is active when the GW6 configuration window is opened. From the View menu a Basic or an Advanced view of the Port configuration tab card can be selected. The Advanced view shows the additional query and echo suppression parameters.
  • Page 12 AS Martem Data Concentrator TELEM-GW6 User Manual • Communication Mode – Makes it possible to choose between the following handshaking options: - No control - Modem Callout – Port 2 - RTS/CTS Control – Port 2 - RS-485 – Port 5 - Tcp/IP –...
  • Page 13: Devices Tab Card

    AS Martem Data Concentrator TELEM-GW6 User Manual 10.3.2 Devices Tab Card Figure 10.3.2. Devices tab card Parameters: • Device nr – Sequence number of the device • Objects – Number of objects in the device • Link address – Link address of the connected device •...
  • Page 14 AS Martem Data Concentrator TELEM-GW6 User Manual • Control takeover addr.^ – The address of an object which determines control takeover of that device • Signals blocking addr.^ – The address of an object which determines blocking of all signals from that device. No signals are sent to control...
  • Page 15: Objects Tab Card

    AS Martem Data Concentrator TELEM-GW6 User Manual Clearing Devices To clear the Device Tab Card, select Clear from the extended control menu. A warning window always appears before removing operations are concluded: Select Yes to accept or No to cancel the removal operation of the devices.
  • Page 16 AS Martem Data Concentrator TELEM-GW6 User Manual Columns: Type – Object’s type: digital input (DI), digital output (DO), analog input (AI), counter (CN) Sub Type^ – Object’s subtype for uplink. The following dialog box opens on clicking: Subtypes of object and time marking mode can be selected.
  • Page 17 AS Martem Data Concentrator TELEM-GW6 User Manual • Invert – Object’s value will be inverted • Fn.code – Function code on the IEC 60870-5-103 protocol • Info no. – Information number on the IEC 60870-5-103 protocol • Index – Object index on the IEC 60870-5-103 protocol. It indicates the order number of the object in message types 3 and 9 of analog measurements.
  • Page 18 AS Martem Data Concentrator TELEM-GW6 User Manual • Forb. Calling – Block object’s value transfer. • Ch. Nr. – Channel nr. for SPA-bus communication protocol noFlags – If set to Yes, removes Invalid and Not Topical flags from • object status. Used for objects, which statuses are not received with General Interval time (short circuit current, etc.)
  • Page 19: Formulas Tab Card

    AS Martem Data Concentrator TELEM-GW6 User Manual Hints • Repeated object addresses are shown on yellow background. • When leaving the Object Tab Card, all the objects are hidden. To see the objects on returning to Object Tab Card, use Expand All from the extended control menu that appears after a right click.
  • Page 20 AS Martem Data Concentrator TELEM-GW6 User Manual Editing formulas Formulas can be created between the values of analog and/or digital objects. Referencing to object values To use the measurement object in the formula, insert an @ sign together with the object address up.
  • Page 21: Rta Io Tab Card

    AS Martem Data Concentrator TELEM-GW6 User Manual Notes • All analog values should be scaled before making calculations; therefore, it is very important to fill the Raw Min, Raw Max, Scale Min, Scale Max fields with Normalized values that are used in calculations.
  • Page 22: Status Tab Card

    AS Martem Data Concentrator TELEM-GW6 User Manual 10.3.6 Status Tab Card Figure 10.3.5 Status tab card Status tab card presents the status of GW6 general configuration parameters and transfer statistics. Update button is used to get information from the connected GW6 and it is displayed under Device Information.
  • Page 23: Common Main Menu

    AS Martem Data Concentrator TELEM-GW6 User Manual 11. Common Main Menu 11.1 Analog Groups Interval groups are used to specify the time interval of sending analog input value to the remote control center when the value has changed less than the deadband.
  • Page 24: Modem Settings

    AS Martem Data Concentrator TELEM-GW6 User Manual 11.3 Modem Settings Configure modem settings for modem callout communication mode (Port 2). 11.5 Port Mirroring To determine 2 mirror groups (2 ports in each group). In case of mirrored ports, the data will be sent and received through both ports, but not simultaneously.
  • Page 25: Communication Cables

    AS Martem Data Concentrator TELEM-GW6 User Manual 12. Communication Cables Cable GW6 – Telem RTU-T RJ45 1. Signal Pin RJ11/4 Pin Signal Connected: Time RJ45 – R11/4 Time GW6 COM 1 Telem RTU RJ45 Signal RJ45 Cable GW6 - Telem RTU-G...
  • Page 26: Notes

    13. Notes • If not stated otherwise on the individual pages of this document, AS Martem reserves the right to make modifications. • Although the contents of this publication have been checked for conformity with the hardware and software described, we cannot guarantee complete conformity since errors cannot be excluded.