Important: Read and save this owner’s guide for future reference. The Inverter’s Output Waveform This chapter contains important safety and installation instructions for our VSP series power inverters. Each time, before using the power inverter, read all instructions and cautionary marking on or provided with inverter and all appropriate sections of this guide.
Page 3
WARNING! RISK OF DAMAGE TO THE INVERTER ▪ FIRE AND BURN HAZARD Never allow battery acid to drip on the inverter when reading gravity, or filling battery. ▪ Never place the inverter unit directly above batteries, gases from a battery will corrode and damage the inverter.
4. Location 5. Inverter Materials List and Indication The power inverter must only be installed in a location that is: Materials List Dry: There are power inverter unit, user manual, DC cables and spare fuse inside of packing. The inverter must be installed in a dry location not subject to moisture especially rain, spray, or splashing Figure 1 (6.1, 6.2, 6.3) bilge water.
Page 5
5. USB Port it output DC 5V 500mA or 2.1A connect the USB external appliance to USB port and switch it on. The USB output on the power inverter provides a supply of 5V DC power for USB external appliances The AC output waveform of the VSP series inverter output waveform is “pure sine wave”. (e.g. lights, fans, radios).
To calculate the approximate power in amps a 24 volt battery bank has to supply you need to know the INTERFERENCE WITH SOME EQUIPMENT current, or amps required for powering the continuous AC load. A shortcut method is to divide the continuous AC load.
Batteries Wiring 2. SERIES – PARALLEL WIRING 1. SERIES WIRING A Series-parallel configuration increases both voltage (to match the inverter’s DC requirements) and capacity (to increase run time for operating the loads) using smaller, lower voltage batteries. In the example below (Figure 6), four 6V DC/200Ah batteries are combined into two strings resulting in a 12V Wiring batteries in a series increases the total battery bank output voltage.
The inverter can be operated in any position, however, if it is to be mounted on a wall, mount it Select a fuse or circuit breaker with a proper rating (e.g.: 1000W advice 150A DC, 1500W advice 200A DC) horizontally (Figure 7) so that indicators, switches, outlets and terminal blocks located on the front panel are visible and accessible.
3. When using an extension cord from the inverter to an appliance the extension cord should not be 10. Trouble Shooting longer than 15 meters. 4. When you plan to operate more appliances, please make sure plug and switch ON the biggest one first No AC output;...
Specifications for VSP Series Inverter: Model VSP300 VSP600 VSP1000 VSP1500 VSP2000 VSP3000 VSP4000 Rated Power (Watts) 300W 600W 1000W 1500W 2000W 3000W 4000W Surge Power(few seconds) 600W 1200W 2000W 3000W 4000W 6000W 8000W Voltage (AC) 220-240V AC (230V) AC Voltage Regulation ±10%...
Page 11
Protection to fix elucidation 11. Maintaining the Inverter According to the prescription, the period for protecting to fix our company’s inverter is two years, (from Minimal maintenance is required to keep your inverter operating properly, periodically you should: the date when you have the invoice). ‣...