Then press 3 and change the mode by pressing 1 or 2 (see Figure 45). Press 4 several times briefly to return to
the home screen.
Menu 05 - Mode Stand-By - Stand by mode for turning the automatic boiler operation on and off
When this mode is on and the boiler reaches the given temperature, it will raise it by 2°C, and if the conditions
are favorable (sustainable temperature), the boiler will shut down. When the given temperature (of water or
boiler room) drops by 2°C below the given value, the boiler will automatically perform the whole startup
procedure.
This mode is recommended only when the boiler room is completely insulated so that the boiler will not have
to turn on or off too frequently. When the mode is off, the boiler will reach the given temperature and go back
to the modulation mode, reducing power until it reaches the operating stage 1, where it will maintain fire with
minimum power.
From the home screen, press 3 (set). Press button 5 four times. The display looks as in Figure 46.
Figure 45
Figure 46