Datcon DT1315 Series Operating Instructions Manual

Intrinsically safe output isolators

Advertisement

Quick Links

DT1315 xx xx
Intrinsically Safe Output Isolators
Operating Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Datcon DT1315 Series

  • Page 1 DT1315 xx xx Intrinsically Safe Output Isolators Operating Instructions...
  • Page 2: Table Of Contents

    DT1315 xx xx Contents 1. About this document .............4 1.1. Function ................... 4 1.2. Target group................4 1.3. Symbolism used............... 4 2. For your safety ...............5 2.1. Authorized personnel ............... 5 2.2. Appropriate use................ 5 2.3. Warning about misuse ............. 5 2.4.
  • Page 3 DT1315 xx xx 6. Fault rectification ............14 6.1. Fault finding................14 6.2. Repairing................14 7. Dismounting ..............15 7.1. Dismounting procedure ............15 7.2. Disposal ................. 16 Appendix...............17 8.1. Technical specification ............17 8.2. Application example ............... 19 8.3. ATEX Certification..............20 20100826-V0...
  • Page 4: About This Document

    DT1315 xx xx 1. About this document 1.1. Function This operating instructions manual has all the information you need for quick set-up and safe operation of DT1315 xx xx. Please read this manual before you start setup. 1.2. Target group This operating instructions manual is directed to trained personnel.
  • Page 5: For Your Safety

    For safety and warranty reasons, any internal work on the instruments must be carried out only by DATCON personnel. 2.2. Appropriate use The DT1315 xx xx is an Intrinsically Safe Output Isolator product family.
  • Page 6: Safety Information For Ex Areas

    DT1315 xx xx 2.6. Safety information for Ex areas Please note the Ex-specific safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments. 2.7. Environmental instructions Protection of the environment is one of our most important duties.
  • Page 7: Product Description

    DT1315 xx xx 3. Product description 3.1. Delivery configuration The scope of delivery encompasses: Delivered items • DT1315 xx xx • documentation: this operating instructions manual certification Warranty 3.2. Type designation 3.3. Principle of operation The DT1315 xx xx Intrinsically Safe Output Isolator provide Area of application signal transmission between the control equipment and signal sources located in the safe area and actuators,...
  • Page 8: Adjustment

    DT1315 xx xx 3.4. Adjustment The DT1315 xx xx doesn’t need any adjustment. After connected to the power supply it is ready to work. 3.5. Indicators The following figure shows the indicator on the instruments front: 1. “power” green indicator indicates the power on state of the instrument.
  • Page 9: Mounting

    DT1315 xx xx 4. Mounting 4.1. General instructions The instrument should be installing in the safe area in a cabinet with sufficient IP protection, where the operating conditions are in accordance with chapter 8.1 Technical specifications, as described under the title: Operating conditions.
  • Page 10: Mounting Procedure

    DT1315 xx xx 4.3. Mounting procedure The following figure shows the mounting procedures (fixing on the rail): Mounting on the rail The mounting doesn’t need any tool. 1. Tilt the instrument according to the figure; put the instrument’s mounting hole onto the upper edge of the rail (figure step 1.).
  • Page 11: Connecting

    DT1315 xx xx 5. Connecting 5.1. Preparing the connection Always observe the following safety instructions: • When you are going to install instruments in hazardous area or install instruments which are connecting to instruments are working in hazardous area you should take note of the appropriate regulations, conformity and type approval certificates of the DT1315 xx xx and other instrument.
  • Page 12: Connecting The Transmitter

    DT1315 xx xx 5.2. Connecting the transmitter The following figure shows the wiring plan, connecting the transmitter: Wiring plan, connecting the transmitter (see also “Application example”) Be careful the polarity of the cables 1. Loosen terminal screws. 2. Insert the wire ends into the open terminals according to the wiring plan.
  • Page 13: Connecting The Signal Processing Unit And The Power Supply

    DT1315 xx xx 5.3. Connecting the signal processing unit and the power supply The following figure shows the wiring plan, connecting the signal processing unit and the power supply: Wiring plan, connecting the signal processing unit and the power supply (see also “Application example”) Be careful the polarity of...
  • Page 14: Fault Rectification

    6.2. Repairing There is no user repairable part inside the instrument. In accordance with Point 2.1.: For safety and warranty reasons, any internal work on the instrument must be carried out by DATCON personnel. 20100826-V0...
  • Page 15: Dismounting

    DT1315 xx xx 7. Dismounting 7.1. Dismounting procedure The following figure shows the dismounting procedures: Dismounting from the rail The dismounting procedure needs a screwdriver for slotted screws. Pull out all the terminals: 1. Put the screwdriver into the slot between the terminal and the housing (figure step 1.).
  • Page 16: Disposal

    DT1315 xx xx 4. Lift the screwdriver handle until it possible to open the fixing assembly (figure step 4.). 5. Keeping the screwdriver in this position lift the instrument bottom from the bottom edge of the rail (figure step 5.). 6.Lift the whole instrument (you may put out the screwdriver) (figure step 6.), as far as the instrument will be free.
  • Page 17: Appendix

    DT1315 xx xx 8. Appendix 8.1. Technical specification Intrinsic safety data: Certification: 05 ATEX 020 X Marking: II (1) GD [EEx ia] IIC / IIB (-20 °C ≤ Ta ≤ +50 °C) 250 Veff Safety data: Limit outputs safety data: 19.1 V 91 mA 570 mW 150 nF...
  • Page 18 DT1315 xx xx Galvanic isolation: Operating isolation voltage: 250 Veff (between the input, the output, and the supply voltage terminals) Test voltage: 2500 VDC (1 min.) (between the input and the output terminals; between the input and the power supply terminals) Power supply: Supply voltage: 19-29 VDC...
  • Page 19: Application Example

    DT1315 xx xx 8.2. Application example 20100826-V0...
  • Page 20: Atex Certification

    DT1315 xx xx 8.3. ATEX Certification 20100826-V0...
  • Page 21 DT1315 xx xx 20100826-V0...
  • Page 22 DT1315 xx xx 20100826-V0...
  • Page 23 DT1315 xx xx 20100826-V0...
  • Page 24 DT1315 xx xx 20100826-V0...
  • Page 25 DT1315 xx xx 20100826-V0...
  • Page 26 DT1315 xx xx 20100826-V0...
  • Page 27 DT1315 xx xx 20100826-V0...

Table of Contents