JAPAN UNIX UNI-SENSOR 701A Operating Instructions Manual

Hide thumbs Also See for UNI-SENSOR 701A:

Advertisement

Digital Thermometer
UNI-SENSOR 701A
Operating Instructions
(For Type 5)
Ver. 5.0.2

Advertisement

Table of Contents
loading

Summary of Contents for JAPAN UNIX UNI-SENSOR 701A

  • Page 1 Digital Thermometer UNI-SENSOR 701A Operating Instructions (For Type 5) Ver. 5.0.2...
  • Page 2: Table Of Contents

    UNI-SENSOR 701A Operating Instructions Table of Contents Introduction .......................1 Precautions ....................1 Features ....................2 Checking the Thermometer ..............2 Specifications ....................2 How to Operate the Thermometer and Descriptions of the Functions ..3 How to Use Each Sensor (Optional) ............7 Sensor Group for Various Applications .............8 Maintenance ...................9...
  • Page 3: Introduction

    1. Precautions Before using the UNI-SENSOR 701A digital thermometer, be sure to read the following cautions and understand them well. Use the UNI-SENSOR 701A digital thermometer under the environment that is regulated with the specifications only.
  • Page 4: Features

    3. Checking the Thermometer Take out the UNI-SENSOR 701A from the package at first. Check the supplied parts one by one from the following figure to see if you have all parts and if any of them is not damaged. If you do not have any of them or if any of them is damaged, contact the dealer from which you have purchased the thermometer.
  • Page 5: How To Operate The Thermometer And Descriptions Of The Functions

    *Auto power off Power OFF: Power OFF in 10 minutes in the ON status *Backlight Back light: Back light OFF in 1 minute after the power supply is turned on in the OFF status The back light can be turned on and off by key switch. *Applicable to Ver.
  • Page 6 * If you do not use the thermometer for a long time, the battery may leak. Be sure to remove the battery from the thermometer. CAUTION * Take care not to mistake the polarity of the battery. * Be sure to use a 9 V alkaline dry cell of type 006. (Manganese dry cell is available.) Turning on or off the thermometer 1) Turning ON/OFF the power...
  • Page 7 3) Backlight Function (Type 5 Additional Function) If the back light is turned on, the temperature can be measured even in a dark place. At delivery, the function is set to ON. * When the power supply is turned on by POWER key while pressing the MODE key in the power OFF status, the back light function is turned on/off.
  • Page 8 5.6 Various HOLD functions HOLD function The current measured temperature data is held and displayed. “HOLD” lights on the display. Selection (Maximum value HOLD function) The maximum Maximum value HOLD function (MAX/HOLD) Maximum temperature display mode temperature is displayed. When “MAX” and “HOLD” are lighting on the display, the A normal measurement value is displayed.
  • Page 9 Errors 6.1 Error messages (1) Indication of the broken sensing edge If the sensing edge of the sensor is broken or if the sensor is not connected to the thermometer, “Err” appears on the display as shown in the right figure. If this message appears on the display, replace the sensor with a new one or connect the sensor to the thermometer.
  • Page 10: How To Use Each Sensor (Optional)

    7. How to Use Each Sensor (Option) ① How to put the surface sensor to the target Put the surface sensor to the contact surface of the target vertically. Note that the thermometer cannot detect the correct temperature if the contact surface of the target is not smooth or flat.
  • Page 11: Sensor Group For Various Applications

    8. Sensor Group for Various Applications Model name Shape Tip of the Operating Feature/Application sensor temperature  You can measure the UNI-9 temperature of an iron tip Sensor for an iron tip Normal correctly. (Supplied with the temperature to + 500°C thermometer))...
  • Page 12: Maintenance

    9. Maintenance About storage When you store the thermometer, avoid places (environment) subjected to:  Direct sunlight  High temperature・High humidity  Vibration  The case of the thermometer is made of ABS resin. Be careful not to bring it close a substance whose temperature is very high so that it cannot be deformed.

Table of Contents