Page 1
Mineral and Salt Chlorinators HMSC20, HMSC26 INSTALLATION & OWNERS MANUAL IMPORTANT Please read carefully WARNING: The installation of Failure to follow this product should these instructions be carried out by a and comply with all person knowledgeable applicable codes in swimming...
Pre-start up procedure Storage and safety Mineral Salt OWNERS MANUAL 2. IMPORTANT INSTRUCTIONS FOR USE 3. OPERATION OF YOUR HENDEN SALT WATER CHLORINATOR 11 Control panel layout 4. HENDEN CHLORINATOR SPECIAL FEATURES System control (sanitiser output dial) Polarity Indicators A & B Low salinity indication 5.
Henden Mineral and Salt Chlorinator Installation Manual INSTALLATION Congratulations! You are now the proud owner of a new Henden Mineral and Salt Water Chlorinator. Please read all information in this manual carefully before installing or operating your Salt Water Chlorinator.
Henden Mineral and Salt Chlorinator Installation Manual 1. INSTALLATION INSTRUCTIONS 1.1 Installing the Power Supply Select a convenient well-ventilated location within one metre of filter equipment and mount the power supply vertically onto a post or wall 1.5 metres above ground level.
Pool pump’s and socket 3 pin plug NOTE: The Henden cell is supplied with a paddle type flow switch, which is to be installed on the cell as shown in the diagram on page 6. Do not use a double adaptor to IMPORTANT The flow switch must be connect more than one pump –...
Henden Mineral and Salt Chlorinator Installation Manual 1.5 Pre-start up procedure Before operating your Henden Pool Sanitiser System please ensure the following quantity of Pool Salt or mineral salt (HMS15) and mineral activator (HMA15) has been added to your pool.
(Refer Day to Day Operation page 16 for further information). (15kg bags) Up to 10,000 0.5 Bag 0.5 Bag Note: When the need arises to top up your pool with Henden Mineral Up to 20,000 1 Bag 1 Bag Salt or Henden Mineral Activator, due to dilution through rainfall Up to 30,000 1.5 Bags...
Page 9
2. MONITOR & MAINTAIN YOUR SANITISER IN-LINE CELL Henden has a “Reverse Polarity” In-Line cell. • To keep your Henden Salt Water Sanitiser in the best possible condition, regular monitoring of the electrolytic cell is recommended. The ‘cell’ is the clear plastic housing containing the plates.
Henden Mineral and Salt Chlorinator Owners Manual OWNERS MANUAL 2. IMPORTANT INSTRUCTIONS FOR USE To minimise the risk of gas build-up in the cell, you must ensure there is sufficient water flow through the cell when the unit is on and producing chlorine.
Henden Mineral and Salt Chlorinator Owners Manual 3. OPERATION OF YOUR HENDEN SALT WATER CHLORINATOR Cell output is expressed as a percentage. Set the system control to the percentage output required and the unit will automatically adjust the cell output to the set level.
Henden Mineral and Salt Chlorinator Owners Manual 4. HENDEN CHLORINATOR SPECIAL 4.3 Low salinity indication FEATURES Your Henden Chlorinator is fitted with a number of protective systems including the operation LED whose primary function includes Low Salinity Indicator. As the 4.1 System control (chlorinator output dial)
100% Henden Mineral and Salt Chlorinator Owners Manual 5. AUTOMATIC TIME CLOCK OPERATION Timer Setting and Functions SELECTOR SWITCH Clock 8:00 Timer 1 - ON Timer 1 - OFF Timer 2 - ON Timer 2 - OFF Automatic IMPORTANT. Certain local electrical Manual - ON regulations state “If the supply cord...
These fuses can beware of “look-a-likes”. Only the genuine Henden cell be sourced from your local Reece Irrigation & Pools is designed and warranted to operate with the Henden branch. However, it is essential that the wall or post to power supply.
Page 15
A flow switch has been supplied with the unit, which will stop sanitisation if low or no flow is detected. Henden Chlorinator units are also fitted with a Thermal Cut-Out to prevent overheating. If the temperature rise is too high, power is automatically disconnected. The unit will resume operation when it cools down.
It is essential in helping retain chlorine in your pool. Chlorine is rapidly dissipated by sunlight The Henden Chlorinator has a built in warning indicator to and the use of stabiliser will reduce this dissipation minimise damage resulting from insufficient TDS levels, substantially.
Henden Mineral and Salt Chlorinator Owners Manual 9. CHLORINE PRODUCTION The Henden Chlorinator must be run daily to generate sufficient chlorine to sanitise the pool. During Summer this is approximately eight hours per day, preferably in two periods - between 6.00 and 8.00am and between 5.00 and 11.00pm.
Henden Mineral and Salt Chlorinator Owners Manual 10. GENERAL INFORMATION 10.1 Pool water chemistry instructions Total Calcium Stabiliser - Recommended POOL WATER Free Chlorine alkalinity TA hardness Cyanuric Acid TDS levels BALANCE (ppm) (ppm) (ppm) (ppm) (ppm) Concrete & Concrete &...
MUST provide evidence of the date of original purchase when making a claim. Henden shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or injury of any kind whatsoever arising directly or indirectly from Henden products.
Need help?
Do you have a question about the HMSC20 and is the answer not in the manual?
Questions and answers