Storage
Store the product between uses and/or during periods of extended inactivity or when transporting. Proceed as follows:
Turn the control knob to the OFF position.
Disconnect the LPG cylinder.
Store the product upright in an area sheltered from direct exposure to inclement weather (rain, sleet, hail, wind,
snow, dust and debris).
If desired, cover the product to protect the exterior surfaces and to help prevent build-up in air passages.
Never leave LPG cylinder exposed to direct sunlight or excessive heat.
NOTICE
Service
Only a qualified service person should repair the gas passages and associated components.
CAUTION

Troubleshooting

Problem
Pilot does not light.
Note: The product operates at
reduced efficiency below 5 °F.
Pilot does not stay lit.
Burner does not light.
Burner flame is low.
Carbon build-up.
Thick black smoke.
Only qualified service persons using approved accessories shall replace components and service internal parts of
the product.
24
Wait until the product is cool before covering.
Always allow the product to cool before attempting service.
Possible cause
Cylinder valve is closed.
Blockage in orifice or pilot tube.
Air in gas line.
Low gas pressure with cylinder
valve fully open.
Piezo ignition
Dirt built up around pilot.
Connection between gas valve
and pilot assembly is loose.
Thermocouple is not operating
correctly.
LPG cylinder is frosted over.
Blockage in orifice.
Control knob is not in ON position. Turn control knob to ON.
Gas pressure is low.
Outdoor temperature is less than
5 °F and tank is less than 1/4 full.
Dirt or film on reflector and
burner screen (inside control
box (8)).
Blockage in burner.
Solution
Open valve.
Clean or replace orifice or pilot tube.
Open gas line and bleed it (pressing control
knob in) for not more than 1 to 2 minutes or
until you smell gas.
Turn cylinder valve OFF and replace
cylinder.
fails.
Use match to light pilot; obtain new igniter
and replace.
Clean dirt from around pilot.
Tighten connection and perform leak
check.
Replace thermocouple.
Wait until the LPG cylinder warms up and
becomes unfrosted.
Clear blockage.
Turn cylinder valve OFF and replace
cylinder.
Use a full cylinder.
Clean reflector and burner screen.
Remove blockage and clean burner inside
and outside.*

Advertisement