Page 1
PREFACE Thank you for choosing a gasoline generator set by our Co. Based on the latest technology at home and abroad, our Co. has successfully developed the gasoline generator set. The unit is characterized by advanced design, compact structure, reliable performance, convenient service, low fuel consumption and noise as well as fashion shape.
Page 2
IMPORTANT NOTICES Please pay special attention to statements preceded by the following words: WARNING: A warning is used to alert the user to fact that hazardous operating and maintenance procedures may result in injury to or death of personnel if not strictly observed. CAUTION: A caution is used to alert the user to fact that hazardous operation and maintenance procedures may result in injury to or death of personnel if not strictly observed.
Ⅰ. GENERATOR SAFETY 1. Never operate it in an enclosed room. Fig.1.2 Fig.1.1 2. Never connect to home circuit. Fig.1.3 Fig.1.4 3. Do not operate it under wet circumstances. 4. Place inflammables away from the unit at least one meter.
Page 5
5. No smoking when filling fuel. Fig.1.5 Fig.1.6 6. Always fill fuel after stopping it. Fig.1.7 7. Do not spill out when filling fuel.
Ⅲ. PRE-OPERATING INSPECTION 1. ENGINE-OIL LEVEL NOTE: always check the generator in the case of stopping the generator on a level ground. 1. Turn out the oil filler cap and clean 3. In the case that the oil the dipstick with lever is below the lower a clear clothe.
Page 10
2. FUEL LEVER 5. Open the fuel filler cap. 6. Check the fuel level, and fill fuel if necessary. 7. Fill fuel to the shoulder of the filter. 8. Reinstall the fuel filler cap well.
Page 11
3. BATTERY (only for 2GF-4) Check and make sure that the electrolyte level of each battery cell is between is upper and lower level marks (Fig.20). 1. upper level mark 2. lower lever mark...
Page 12
4. AIR CLEANER 1. Remove the clip and dismantle the air housing (for 1.3GF-3&2GF-3) or turn off the wing nuts and air cleaner cover (for 1.3GF, 1.3GF-2, 2GF&2GF-2). Fig.3.12 4. Put the filter element into original position, install the cover and secure it well Fig.3.10...
Ⅳ. STARTING THE GENERATOR 4. Turn the generator ignition switch to “ON”. 1. Remove all loads form AC socket and switch off the AC breaker. Remove all loads from AC socket. Fig.4.4 Fig.4.1 2. Set the fuel cock to “ON”. Fig.4.2 3.
NOTE: Don’t close the choke when starting the engine in hot condition. Ⅴ. SERVICE Always do as the following so as to keep the generator in a sound condition. WARNING 1. Always connect the generator to the earth to prevent misusing. 1.3GF&2GF Fig.5.1 Fig.5.2...
Page 15
2. The following table gives reference information for connection the electric appliances to generator. Wattage Example Description Typified Start Rating Electric device Start Rating Incandescent lamp Incandescent lamp ● Incandescent lamp 100VA 100VA ● Heating device ×1 100W Fluorescent lamp Fluorescent lamp ●...
Page 16
3. If the generator is to supply two or above loads with power supply, be sure to connect them one by one with higher start current first. Fig.5.3...
Page 17
WARNING When connect the generator to home power supply, be sure that a skilled electrician does this job. ]Improper connecting between the generator and loads may cause damage to the generator, even a fire.
Page 18
4. USE INSTRUCTION WHEN PROVIDING ALTERATIVE CURRENT SUPPLY 1. Start the generator 3. Switch on the AC breaker. 2. Connect devices...
Ⅵ. STOPPING THE ENGINE 3. Set the fuel cock to “OFF”. 1. Switch off the AC breaker. 2. Turn the ignition switch to “OFF”. NOTE: To stop the generator in an emergency, turn the ignition switch to “OFF”.
Ⅶ. MAINTERNANCE User should service the unit according to the Maintenance Schedule as follows: PERIOD ITEM Or first Or every Or every Or every one Ref. month 3 months 6 months Year page Engine oil check Check Replace engine oil Replace Replace P.20...
Page 21
1. REPLACEMENT OF ENGINE OIL 1. Turn and then take out the dipstick. 3. Screw on the drain plug. 5. Reinstall the dipstick. 2. Turn off the drain plug, and empty 4. Fill engine oil to the upper level the engine oil from the crankcase. mark of the dipstick.
Page 22
2. MAINTENANCE OF AIR CLEANER (SEE ABOVE-MENTIONED) 3. SPARK PLUG 1. Withdraw the spark plug cap front the spark plug. 3. Clear away carbon fouling around the spark plug. Fig.7.6 Fig.7.8 4. Check the spark plug gap and adjust if necessary. 2.
Page 23
4. MAINTENANCE OF FUEL FIL TER 1. Set the fuel cock to “OFF” , and dismantle the fuel 3. Fit a new rubber ring to position and mount the filter cup securely. filter cup. 2. Clean the fuel filter cup thoroughly by blowing off in the reverse direction of the arrowhead.
Ⅷ. STORAGE During long-term storage of the unit which are not kept in use, carry out procedures as follows; 1. Set the fuel cock to “OFF”, turn off the filter cap 4. Screw off the fuel drain plug, and empty the fuel and empty the fuel inside.
Page 25
6. Reinstall the oil drain plug, and then fill engine oil 8. Place the unit in the clean area. to the upper level mark of the dipstick. Fig.8.8 Fig.8.6 7. Pull up the handle gently until feeling an anti-action. Fig.8.7...
Ⅸ. TROUBLESHOOTING 4. Remove the spark plug, and check it for proper (1) TROUBLE: the generator fails to start. sparks. 1. Check to see of the generator switch is at “ON” 5. If the generator set if still out of work, see your 2.
Page 27
(2) TROUBLE: The unit fails to generator electricity. 2. Check to see if the AC breaker is at “ON”. 1. Check the light bulb. 3. If such check is still unsatisfactory, see your dealer for help.
Ⅺ. SPECIFICATONS Model 1.3GF 1.3GF-2 1.3GF-3 1.5GF-3 Engine model 168F 168F 168F 168F 4-stroke, OHV, single cylinder gasoline engine Type with forced air-cooled Displacement (cm Maximum power output 4.0/3600 4.0/3600 4.0/3600 4.0/3600 (kW/rpm) Ignition system Non-contact transistor Engine Start system...
Page 32
Model 1.3GF 1.3GF-2 1.3GF-3 1.5GF-3 Overall length (mm) Overall length (mm) Generating set Overall length (mm) Dry mass (kg) SPECIFICATONS Model 2GF-2 2GF-3/4 2.5GF-3 Engine model 168F-2 168F-2 168F-2 168F-2 4-stroke, OHV, single cylinder gasoline engine Type with forced air-cooled...
Page 33
Rated voltage (V) 220、230、240 110/220、120/240 110、120 Rated frequency (Hz) Generator Rated power (KVA) Max. power (KVA) Overall length (mm) Overall length (mm) Generating set Overall length (mm) Dry mass (kg) 45/47 BATTERY To install the battery, proceed as follows; 1 Assemble the battery with nuts, bolts and washers. 2 Connect the starting cable to the starting motor terminal alone the bottom of the fuel tank.
Page 34
(1) Starting motor (2)Starting cable (3) Protective frame (4) Battery bracket (5) Battery guard (6) Retaining frame (7) Battery (with a rating of 12V-35Ah) (8) Negative wire...
Need help?
Do you have a question about the 1.3GF and is the answer not in the manual?
Questions and answers