Progamming command reference
Commd Description
00
Begin programming
10
Add PIN
11
Delete PIN
12
Set privileges
13
Delete group
14
Enable group
15
Disable group
21
Set Group 1 Sprvsr PIN PIN
22
Set Group 2 Sprvsr PIN PIN
23
Set Group 3 Sprvsr PIN PIN
24
Set Group 4 Sprvsr PIN PIN
25
Set Group 5 Sprvsr PIN PIN
99
End programming
Commands only for the Administrator
20
Set Administrator PIN PIN
30 †
Set PIN length
32
Set unlock duration
33 †
Reset all
*
Enter 0 to allow no privileges, 1 for passage mode
only, 2 for deadbolt override only, or 3 to allow both.
† Warning! These commands erase all programming
and set the Administrator PIN back to its default.
www.bestaccess.com
T80912/Rev A
1880935 ER7991-37 Apr 2003
Code 1 Code 2
PIN
Group (1–5)
PIN
*
0,1,2 or 3
Group (1–5)
Group (1–5)
Group (1–5)
repeat PIN
repeat PIN
repeat PIN
repeat PIN
repeat PIN
repeat PIN
3,4,5 or 6
1–60 (secs)
33