Take the provided safety tether and loop one end
of the tether to existing rough-in kit.
Connect two
quick connects
8
Connect the fixture assembly to the driver enclosure
assembly with the supplied quick connects and
assemble the connector housing when finished.
Position fixture so
rough-in kit
support arms do not
interfere with springs
10
Position the fixture below the ceiling so that two of the
three springs are on each side of the rough-in kit support
arms. This is necessary in order to make sure that when
the springs release, the rough-in kit support arms don't
interfere and prevent the springs from making contact
with the top of the ceiling for proper support.
NOTE: Ensure the fixture is positioned properly before
installing in the ceiling so the springs don't interfere with the
support arms.
Assembled connector
housing
4
Toggle
Button stop
7
Attach the other end of the safety tether to the
fixture using one of the three holes located on the
fixture brackets. Feed the button stop and toggle
through the hole and slide into the hole in the
bracket. Allow the fixture to hang freely.
9
Cut cable tie on fixture so that the fixture is ready
to be installed.
11
Push fixture through the hole in the ceiling. This will
engage the protruding arms, thus, releasing the
springs. The springs will draw the fixture up into the
ceiling and hold it there tightly.
CAUTION
RISK OF PERSONAL INJURY -
appendages are in the path of the torsion springs
as they are a pinch hazard when released. The
springs will release when the arm is flexed downward.
Be cautious that no body part is in the path of the
spring when released.
Safety
tether
Feed button stop
and toggle through
hole in bracket
Final
installation
position for
springs
Operators shall ensure no