OPERATION - LPH125
7.1.
Ensure that the installation is gas-tight, ensuring all the provisions of section 5 have been met.
7.2.
Open the shutter on side of the burner chamber to reveal the pilot flame window (fig.5).
7.3.
Turn the control knob (fig.6.2.) anticlockwise to the 'pilot' position and push in.
7.4.
Press the igniter button repeatedly until the pilot flame is seen to be lit within the burner chamber.
7.5.
Keep the control knob depressed until the pilot flame is stable, then release and turn the knob
anticlockwise until 'on' is uppermost: the burner will now ignite and settle to a steady flame.
7.6.
Close the shutter over the pilot flame window to guard the pilot flame from draughts.
NOTE: On first use and after connecting a fresh gas cylinder, hold the control knob in for an extra
amount of time, allowing air to be purged from the delivery pipe. Keep clicking the igniter button
until the gas ignites.
7.7.
To turn off:
7.7.1. If turning off for a short period: turn the control knob to the 'pilot' position; the main burner will
extinguish leaving the pilot flame alight.
7.7.2. To turn off fully: turn the control knob to the 'pilot' position then press in for
about ¼ of its travel when it can be turned clockwise to the 'off' position.
Both the main burner and pilot light will be extinguished.
7.7.3. Screw down the tap on the gas cylinder.
7.8.
The pressure regulator is factory set and no adjustment is possible.
DO NOT replace with anything but the correct valve for this heater.
NOTE: Some paint discolouration will occur during use: this is to expected.
WARNING! Remember that the heater will stay hot for a considerable
time after being extinguished. DO NOT attempt to move until cooled
thoroughly.
8. CLEANING & MAINTENANCE
WARNING! DO NOT undertake any cleaning or maintenance whilst the heater is connected to the gas supply. Ensure that the heater
has cooled thoroughly before working on it.
8.1.
The heater should be cleaned at least annually; more often if being used in dusty conditions.
8.2.
To clean the heater, use a damp cloth to remove dust; a household cleaner may be used for more stubborn marking.
8.3.
To clean the reflector on the LPH35, remove the grille by taking the four securing screws out. Ensure that the grille is replaced before
further use.
8.4.
The most effective way to clean the interior is to blow out with compressed air. The gas jet should be cleaned by blowing air into it in the
opposite direction from the gas flow.
8.5.
Inspect the heater, hose and regulator before each use, checking gas connections with a proprietary leak detector spray. This
will show a gas leak as bubbles forming on the connection. Alternatively, a weak mixture of liquid soap and water can be used.
8.6.
If any damage to the gas hose is seen, the hose should be replaced by one of the same specification.
8.7.
Similarly, the gas regulator may only be replaced by an identical 37mbar unit.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
© Jack Sealey Limited
Environmental Protection
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
www.sealey.co.uk
01284 757500
sales@sealey.co.uk
01284 703534
LPH35,LPH125 Issue: 1 - 23/07/14
fig.5
fig.6

Advertisement

loading

This manual is also suitable for:

Lph125