Download Print this page

Sealey LP35.V5 Instructions

Propane heaters

Advertisement

Quick Links

Models: LP35.V5, LP70, LP80.V4, LP100.V2, LP145.V2, LP200.V3 & LP300.V4
Thank you for purchasing a Sealey Propane Heater. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1.
PLUG & MAINS POWER SUPPLY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices.
A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current
Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an
RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
NOTE: 110 volt heaters are usually operated by connecting to a transformer or a generator. Check to ensure all supply equipment is compatible
with the rating of the heater.
1.1.1. The Electricity at Work Act 1989 requires all portable electrical appliances, if used on business
premises, to be tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least
once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for
the safe condition of those appliances and the safety of the appliance operators. If in any doubt
about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the
power supply. See 1.1.1. and 1.1.2. and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all connections
to ensure that none is loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply to be
used and that the plug is fitted with the correct fuse - see fuse rating on right.
1.1.7. Important: For use with a 110 volt supply - ensure that the 110 volt transformer or generator
is adequately rated.
1.1.8. DO NOT pull or carry the appliance by the power cable.
1.1.9. DO NOT pull the plug from the socket by the cable.
1.1.10. DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item
repaired or replaced by a qualified electrician. When an ASTA/BS approved UK 3 pin 13 amp
plug or 110 volt plug is damaged, cut the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only - see diagrams on right).
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been correctly
connected, that the cable outer insulation extends beyond the cable restraint and that
the restraint is tight.
1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted
is preferred since any appliance plugged into it will be protected. The cable core section is important and should be at least 1.5mm
to be absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets,
we recommend the use of 2.5mm
1.2.
GENERAL SAFETY
 WARNING! Disconnect heater from mains supply before servicing or performing maintenance. Replace or repair damaged parts. Use genuine
parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
Store gas cylinders in accordance with regulations applicable to such appliances.
Ensure nothing is standing or passing in front of the heater. Mandatory minimum distance from the heater is 1mtr.
Use the supplied pressure regulator only.
Ensure continuous ventilation is provided to the heater operating area. A ventilation opening must run to the outside of the premises where the heater is
to be operated. The opening must be 25cm
Ensure that the heater is correctly turned off when not in use.
DO NOT use the heater if damaged. Take immediate action to repair or replace damaged parts. Use an authorised service agent only.
DO NOT allow untrained persons to ignite the heater.
DO NOT operate the heater without the cover.
DO NOT exceed the 100W/mtr
DO NOT use a naked flame to try and ignite the heater.
DO NOT use the heater near flammable material - liquids, solids or gases.
DO NOT obstruct the air inlet and outlet sections of the heater.
DO NOT point the heater at the gas cylinder.
Keep the heater clean and in good working order and store in a safe area, out of the reach of children.
 WARNING! If the heater is used for prolonged periods at maximum power, ice may form on the propane cylinder. This is due to excessive
evaporation. In such a case DO NOT use the heater to de-ice the cylinder.
2
section cable.
2
for every kW and must also be set at an equal distance from the upper and lower parts of the heater operating area.
3
limit considering the volume of the empty operating area.
InSTRUCTIonS FoR:
PROPANE HEATERS
LP35.V5, LP70, LP80.V4, LP100.V2, LP145.V2, LP200.V3 & LP300.V4 - 2 - 210108
Yellow & Green
Earth Wire
Blue
Neutral
Wire
Cable
Restraint
FUSE RATING 13 AMP
Blue
Brown
Neutral
Live
Connection
Connection
Yellow &
Cable
Green
Restraint
Earth Wire
Connection
Brown
Live
Wire
2
, but

Advertisement

loading

Summary of Contents for Sealey LP35.V5

  • Page 1 Models: LP35.V5, LP70, LP80.V4, LP100.V2, LP145.V2, LP200.V3 & LP300.V4 Thank you for purchasing a Sealey Propane Heater. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.
  • Page 2 If the flame shuts off during normal operation due to overheating the cause of the problem must be determined and corrected before repeating the ignition procedure. LP35.V5, LP70, LP80.V4, LP100.V2, LP145.V2, LP200.V3 & LP300.V4 - 2 - 210108...
  • Page 3 21st January 2008 93/68/EEC CE Marking Directive Gas Appliances (Safety) Regulations 1992 For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products. 2006/42/EC Machinery Directive NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

This manual is also suitable for:

Lp70Lp80.v4Lp100.v2Lp145.v2Lp200.v3Lp300.v4