The I3 input can be used, at all times, to replace the coded actuator with a second
actuator. By activating this input, the device gets ready for programming mode with the
IN LED orange light fl ashing, it deactivates all the OS1, OS2, O3 and O4 outputs and
then releases the actuator. Keep the input active while inserting the second actuator.
Acquisition of the second actuator is confi rmed by the IN LED switching off and by
four fl ashes of the ACT LED. At this point, it is possible to deactivate the I3 input. The
device will automatically be brought to the restart state and the fi rst actuator is no
longer detected.
The second actuator will have to be adequately fi xed to the protective device as
explained in section MOUNTING INSTRUCTIONS.
This operation must not be carried out as a repair or maintenance operation. In the
case where the device stops working correctly, replace the entire device and not just
the actuator.
5.5 Reset input
The following error states due to a device external failure can be reset using the I3
input:
- a short circuit or overload of safety outputs (OS1 and OS2),
- short circuit between a safety output and the supply voltage,
- excessive misalignment between a safety device and a locked actuator.
5.6 Series connection with safety modules
It is possible to install several devices in cascade connection up to a maximum number
of 32 units, while maintaining safety category 4 / PL e according to EN ISO 13849-1
and SIL CL 3 integrity level according to EN 62061.
Check that the PFHd and MTTFd values of the system comprising the series connec-
tion of devices and the whole safety circuit meet the SIL/PL requirements prescribed
for the application.
Application example with single-channel
locking control function
+ Vcc
AC-L300-xCA•
IS1
IS2
L300
I4
OS1
OS2
AC-L300-xCA•
IS1
IS2
L300
I4
OS1
OS2
AC-L300-xCA•
IS1
IS2
L300
I4
OS1
OS2
Ixx
Ixx
Ox
MSI 400
Device in mode 1
Locking device detection function (protective
device interlocked): 2 channels / category 4 /
up to SIL 3 / PL e
Locking control function:
1 channel / category 2 / up to SIL 2 / PL d
Device in mode 2
Interlock detection function (protective device
closed): 2 channels / category 4 / up to SIL 3
/ PL e
Locking control function:
1 channel / category 2 / up to SIL 2 / PL d
When connecting the devices in series as described above, observe the following:
- Connect the inputs of the fi rst device in the chain to the power supply.
- The OS1 and OS2 safety outputs of the last device in the chain must be con-
nected to the safety circuit of the machine.
- Where a safety module is used, check that the properties of OS1/OS2 safety out-
puts are compatible with the safety module inputs (see section INTERFACING).
- Observe the limits of the output cable stray capacitance, as specifi ed in the
electrical data (see section TECHNICAL DATA).
- Check that the cascade response time fulfi lls the requirements of the safety
function to be obtained.
- The chain response time must be calculated taking into account the response
time of each device.
- When using Y-cables for series connection, special attention must be paid to
the fl owing currents, cable cross-sections and cable lengths in order to ensure
that the supply voltage of the components at the end of the series connection is
within the specifi ed electrical limits of the L300 during operation.
5.7 Operating states
PWR
IN
OUT
ACT
LOCK
LED
LED
LED
LED
O
O
O
O
Flashing
Flashing
Flashing
Flashing
Flashing
green/
green/
green/
green/
green/
red
red
red
red
Green
O
O
Green
Green
Green
Green /
O
orange,
fl ashing
Application example with two-channel lock-
ing control function
+ Vcc
AC-L300-xCA•
IS1
IS2
L300
OS1
OS2
AC-L300-xCA•
IS1
IS2
L300
OS1
OS2
AC-L300-xCA•
IS1
IS2
L300
OS1
OS2
Ixx
Ixx
MSI 400
Device in mode 1
Locking device detection function (protective
device interlocked): 2 channels / category 4 /
up to SIL 3 / PL e
Locking control function:
2 channels / category 4 / up to SIL 3 / PL e
Device in mode 2
Interlock detection function (protective device
closed): 2 channels / category 4 / up to SIL 3
/ PL e
Locking control function:
2 channels / category 4 / up to SIL 3 / PL e
Device
EDM
a
Description
LED
status
O
O
OFF
Device switched off.
Flashing
POWER
Internal tests at switching on.
green/
ON
red
red
Green
RUN
Safety inputs of the device
not active.
RUN
Activation of safety inputs.
RUN
Noncoherent safety inputs.
Recommended action: check
input signal activation and/or
wiring of inputs.
PWR
IN
LED
LED
Green
Green
Green
Green
Green
Green
Green
Green
Orange Orange
Green
Green
Green
IE1
IE2
Green
O
IE1
IE2
IE1
IE2
Red
O
OS1
OS2
Red,
O
fl ashing
Green
Green
Green
Green
O
O = off
= indifferent
5.8 Interfacing
Connection to the MSI-SR-LC21
safety module
Input confi guration with monitored start
A1
A1
MSI-SR-LC21
S21
S22
EDM connection
Attention: if all OS safety outputs are con-
nected directly to a safety contactor, we recom-
mend using fast-switching diodes connected in
parallel to the contactor coils.
A1
L300-xx-M5xx
5
OUT
ACT
LOCK
Device
EDM
a
LED
LED
LED
Green
Red,
fl ashing
Green
Green
O
Green
Green
Green
O
Green
Green
O
Green
Green
O
Orange
Green
O
O
Red,
ERROR Error on safety outputs.
fl ashing
O
Red,
O
O
ERROR Actuator detection error.
fl ashing
O
O
O
O
ERROR Internal error. Recommended
O
O
O
O
ERROR Temperature error: outside
O
Green
Green
Green
Green
O
O
O
O
Red,
ERROR Error in EDM function
fl ashing
(a) = only available with the L300-xx-M5xx version
Connection to the MSI 400 safety
The connections vary according to the pro-
IS2
A2
L300
OS2
A1
S33
S31
Ixx
S34
A2
A2
OS2
Description
status
RUN
Actuator in safe area. O3
signal output active.
RUN
Noncoherent inputs IE1
and IE2 for electromagnet
activation.
Recommended action: check
input signal activation and/or
wiring of inputs.
RUN
Actuator in safe area and
locked, O3 and O4 outputs
active.
RUN
Mode 1: activation of IS1 and
IS2 safety inputs. Actuator
in safe area and locked. O3,
O4, OS1 and OS2 outputs
active.
RUN
Mode 2: activation of IS1 and
IS2 safety inputs. Actuator
in safe area. O3, OS1, and
OS2 outputs active.
RUN
Mode 3: Actuator present,
protective device closed
and locked, IS1 active, IS2
not active, OS1 active, OS2
not active
RUN
Mode 3: Actuator present,
protective device closed
and not locked, IS1 and IS2
active, OS1 not active, OS2
active
Recommended action:
check for any short circuits
between the outputs, outputs
and ground or outputs and
power supply, then restart
the device.
Check for physical integrity
of the device. In case of
damage, please replace the
entire device. If undamaged,
realign the actuator and
restart the device.
action: restart the device. If
the fault persists, replace
the device.
the permissible range
RUN
EDM signal active (external
a
relay off)
RUN
EDM signal not active (exter-
a
nal relay on)
a
module
gram of the safety module
IS2
A2
A1
IS2
A2
L300
L300
OS2
OS2
Ixx
Ixx
Ixx
MSI 400