1 INFORMATION ON THIS DOCUMENT
1.1 Function
The present operating instructions provide information on installation, connection and
safe use for the following parts: L300, AC-L300-xCA
1.2 Target audience
The operations described in these operating instructions must be carried out by quali-
fi ed personnel only, who are fully capable of understanding them, and with the techni-
cal qualifi cations required for operating the machines and systems in which the safety
devices are to be installed.
1.3 Area of application
These operating instructions apply exclusively to the devices listed in section Func-
tion, and their accessories.
1.4 Original instructions
The German language version is the original set of operating instructions. Versions
provided in other languages are translations of the original instructions.
2 SYMBOLS USED
This symbol indicates any relevant complementary information
Attention: Any failure to observe this warning note can cause damage or mal-
function, including possible loss of the safety function.
3 DESCRIPTION
3.1 Device description
The safety device described in these operating instructions is defi ned as a
coded, type-4 interlock device with guard interlocking and without contact acc. to
EN ISO 14119.
The safety switches with electromagnet and RFID technology, for which these oper-
ating instructions apply, are safety devices for the monitoring of gates, safety doors,
enclosures and all protective devices that safeguard the parts of machines with or
without stopping time.
3.2 Intended use of the device
- The device described in these operating instructions is designed to be used on
industrial machines for condition monitoring of movable protective devices.
- The direct sale of this device to the public is prohibited. Installation and use must
be carried out by qualifi ed personnel only.
- The use of the device for purposes other than those specifi ed in these operating
instructions is prohibited.
- Any use other than as expressly specifi ed in this operating manual shall be con-
sidered unintended by the manufacturer.
- Also considered unintended use:
a) Using the device after having made structural, technical, or electrical modifi ca-
tions to it;
b) using the product in an area of application other than as described in section
4 MOUNTING INSTRUCTIONS
Attention: Installing a protective device is not suffi cient to ensure personnel
safety or compliance with machine safety standards or directives. Before installing a
protective device, perform a specifi c risk analysis in accordance with the key health
and safety requirements in the Machinery Directive. The manufacturer guarantees
only the safe functioning of the device to which these operating instructions refer, and
not the functional safety of the entire machine or system
4.1 Actuation directions
The centring symbols
on the device and actuator must be aligned with each
other.
4.2 Selection of the actuator type
Attention: The switch is available with two RFID actuator types: one with a high
coding level (part AC-L300-UCA) and one with a low coding level (part AC-L300-
SCA). In the case where an actuator with a low coding level has been chosen, ensure
that the additional specifi cations prescribed in section 7.2 of the EN ISO 14119:2013
standard are respected during installation.
Attention: If the chosen actuator has a low level of coding, any other low level
coded actuators present in the same place where the device has been installed must
be segregated and kept under strict control in order to avoid any bypassing of the
safety device. If new low level coded actuators are fi tted, the original low level coded
actuators must be disposed of or rendered inoperable.
© Leuze electronic GmbH + Co. KG, In der Braike 1, 73277 Owen, Phone: +49 (0) 7021/573-0, Fax: -199, info@leuze.de, www.leuze.com Subject to modifi cations 2019/03/22 Part no. 50130051
It is advisable to use actuators with a high coding level so as to make the installa-
tion safer and more fl exible. This will render it unnecessary to screen the device, to fi t it
in non-accessible areas or to follow other prescriptions specifi ed by the EN ISO 14119
standard for actuators with low coding level.
4.3 Selection of the operating principle
Attention: The safety switch is available with two operating principles:
1. SLM24 operating principle (quiescent current principle - The locking element is
held in the protective position by spring force): actuator locked if electromagnet
is deactivated.
2. MLM24 operating principle (open circuit current principle - The locking element is
held in the protective position by electromagnetic force): actuator locked if electro-
magnet is activated.
With the SLM24 operating principle (quiescent current principle), the actuator stays
locked even if the machine is disconnected from the power supply. Therefore, if the
machine has dangerous movements with inertia, inaccessibility to dangerous parts
(actuator locked) is ensured, even in the event of a sudden power failure. On the
contrary, if the machine structure allows a person to enter the danger area with the
whole body and possibly end up being stuck inside the machine, the switch must be
provided with an escape release button, in order to allow the trapped person to get out
even in case of power failure.
With the MLM24 operating principle (open circuit current principle), the actuator stays
locked only when the machine is connected to the power supply. Therefore, before
choosing this operation principle, carefully evaluate all dangers deriving from sudden
power failure with a possibly immediate actuator release.
The choice of SLM24 or MLM24 operating principle must always be made following a
risk analysis of the specifi c application.
In case of machines without inertia, i.e. with dangerous elements being immedi-
ately blocked as soon as the safety door is opened, for which a safety device with lock
has been chosen merely to safeguard the production process, the quiescent current
principle or the open circuit current principle can both be used.
4.4 Operating mode selection for activation of safety outputs
Warning: the device is available with three different safety outputs activation
modes:
- Mode 1 (part L300-xxx-Mx1-xx): safety outputs active if actuator is inserted
and locked;
- Mode 2 (part L300-xxx-Mx2-xx): safety outputs active if actuator is inserted;
- Mode 3 (part L300-xxx-Mx3-xx): OS1 safety output active if actuator is inserted
and locked and IS1 is active, OS2 safety output active if actuator is inserted and
IS2 is active.
Mode 1 activates the OS safety outputs when the actuator is both inserted and locked,
so that the actuator cannot be extracted with the safety outputs activated. In mode 1
the device is coded, type 4 (interlock with lock) acc. to EN ISO 14119.
In mode 2, the actuator can be locked/unlocked for special applications while still kept
on the safety chain, typically for specifi c applications without stopping time, when the
risk does not continue after the opening of the protective device. In mode 2 the device
is coded, type 4 (interlock without lock) acc. to EN ISO 14119.
For specifi c applications, mode 3 provides a channel with "mode 1" functionality, and a
channel with "mode 2" functionality. This allows emulation of electromechanical inter-
lock devices with guard interlocking, without complex machine wiring modifi cations.
Using modes 2 and 3 must always follow a risk analysis on the specifi c application,
with particular focus on the function of cascaded mode 3 devices.
1

Advertisement

loading

Summary of Contents for Leuze electronic L300

  • Page 1 If new low level coded actuators are fi tted, the original low level coded actuators must be disposed of or rendered inoperable. © Leuze electronic GmbH + Co. KG, In der Braike 1, 73277 Owen, Phone: +49 (0) 7021/573-0, Fax: -199, info@leuze.de, www.leuze.com Subject to modifi cations 2019/03/22 Part no. 50130051...
  • Page 2 4.5 Mounting the device 4.8 Escape release button Before mounting the device: if necessary, it is possible to Some of the device versions are provided with an escape release button in order to adjust the position of the head and the auxiliary release (if allow any personnel accidentally trapped inside the machine to get out.
  • Page 3 4.10 Electrical connections of the device Power supply input +24 VDC / device 1 LED All L300 device models are supplied with a wire bridge between IE1 (pin 8) and IE2 Power supply input +24 VDC / device 2 LED (pin 9) of the internal terminal strip.
  • Page 4 O4 output are activated; at the same time the RFID sensor increases its switching and deactivation of external contactors must follow the state of the L300 switch distance, so as to ensure that no vibrations or impacts occurring with the protective safety outputs within a maximum delay.
  • Page 5 L300 during operation. mend using fast-switching diodes connected in parallel to the contactor coils.
  • Page 6 diagram, therefore the functional test sequence detailed below is to be consid- 6 INSTRUCTIONS FOR PROPER USE ered as minimal and not exhaustive. - Perform the following sequence of checks before the machine is commissioned 6.1 Installation and at least once a year (or after a prolonged shutdown): 1.
  • Page 7: Technical Data

    Type 4 according to EN ISO 14119 Response time of safety outputs to Coding level acc. to EN ISO 14119: Low level with AC-L300-SCA actuator actuator extraction: Typically 120 ms, max. 200 ms High with AC-L300-UCA actuator Min. distance between two identical devices...
  • Page 8 Leuze electronic GmbH + Co. KG In der Braike 1, D-73277 Owen/Germany The safety sensors of the L300 series have been developed and manufactured in accordance with the applicable European standards and directives. The manufacturer of the product, Leuze electronic GmbH + Co. KG in D-73277 Owen, possesses a certifi...