Summary of Contents for VMC FHB Series

  • Page 1 TÀI LIỆU HƯỚNG DẪN SỬ DỤNG CÂN ĐIỆN TỬ COMPACT SCALE BALANCE INSTRUCTION MANUAL WEIGHT SCALES THINH PHAT SCALES JONT STOCK COMPANY 57 Street D1 , Ward 25, Binh Thanh District, HCMC. Tel : (08) 62.999.111 – 62.888.666 Fax (08) 3512.7699 www.canthinhphat.com - Email : hcm@canvina.com...
  • Page 2 FHB SERI HƯỚNG DẪN SỬ DỤNG CÂN ĐIỆN TỬ VMC FHB 1. Xin đặt cân ở vị trí vững chắc, mặt bàn bằng phẳng , không đặt trên giá đỡ dao động hoặc chấn động, đồng thời điều chỉnh 4 chân để sao cho cân được thăng bằng, chú ý giọt nước thăng bằng phải nằm chính giữa vòng tròn.
  • Page 3 4. Đén báo LO-BAT cân đang sắp hết PIN Kích thước cân VMC FHB II . KHI SỬ DỤNG CÂN VMC FHB - Bật công tắc phía dưới cân màn hình Và nhấn mở cân bằng phím ON/OFF cân kiểm tra từ...
  • Page 4 Lưu ý: Khối lượng trừ bì và khối lượng cần cân cộng lại không quá khối lượng tốt đa cho phép lớn nhất của cân. Ví dụ : Cân Kỹ thuật VMC FHB – phạm vi đó MAX 300g khi ta trừ bì...
  • Page 5 FHB SERI IV. NGUYÊN LÝ CÂN KỸ THUẬT Lực Đĩa cân Loadcell Tín hiệu tương tự Bộ chỉ thị Bộ Bộ chuyển đổi A/D (Weighing Khuếch và bộ vi xử lý indicator) Đại Hình: Sơ Đồ Nguyên Lý Cân kỹ thuật là loại cân điện tử một loadcell. Nguyên tắc hoạt động được mô tả như sơ đồ...
  • Page 6 Các Đặc trưng kỹ thuật chính Các mẫu cân đĩa VMC FHB là các mẫu cân kỹ thuật thông dụng được phát triển và sản xuất bởi hãng TPS Corporation sản xuất theo đơn đặt hàng của Công ty Cổ Phần Cân điện tử...
  • Page 7 FHB SERI V. HƯỚNG DẨN HIỆU CHUẨN CÂN VMC FHB Hiệu chuẩn cân VMC FHB Yêu cầu Chuẩn bị bộ quả cân F1 tới 1kg Các bước hiệu chuẩn cân VMC FBH như sau Bật Cân Bằng công tắc phía dưới cân...
  • Page 8 FHB SERI Ví dụ : Cách hiệu chuẩn cân kỹ thuật VMC FHB600 max 600g d=0.01g Ta thực hiện các bước sau Bật Cân Bằng công tắc phía dưới cân Mở cân bằng Cân kiểm tra số từ 999999 về 000000 Phim ON/OFF “---------“...
  • Page 9 FHB SERI dùng không sử dụng thường xuyên bình ắc quy nên táo nó ra . ân kỹ thuật sử dụng pin sạc 6V/1.3AH , khi cần thay ắc quy người dùng nên xem kỹ màu sắc của dây kết nối (đỏ +, đen -), Xin dùng ổ...
  • Page 10 FHB SERI COMPACT SCALE BALANCE INSTRUCTION MANUAL WEIGHT SCALES THINH PHAT SCALES JONT STOCK COMPANY 57 Street D1 , Ward 25, Binh Thanh District, HCMC. Tel : (08) 62.999.111 – 62.888.666 Fax (08) 3512.7699 www.canthinhphat.com - Email : hcm@canvina.com - 9 -...
  • Page 11: Before Weighing

    FHB SERI WEIGHING Before weighing Whenever possible, please allow the balance to warm up for 10 minutes after first turning to power on, so that the balance will function properly and accurately. Error messages Err-O: Overload Err-Z: Exceed zero track range when turn on the power Err- S: The scale is unstable when turn on the power Low battery...
  • Page 12: Installing Batteries

    FHB SERI PREPARATION 1. Installing batteries Batteries Battery switch power compartment 6AA batteries 2. Setting up the scale/balance △ CAUTION Avoid installing the scale/balance in direct sunlight that may cause discoloration or malfunctions. Place your scale/balance on a firm weighing table so that the scale/balance is level.
  • Page 13 FHB SERI key: Press this button to key: Turn the power toggle between different on or off. weighing units key: For counting function key: Press this button to deduct the weight of the container.. key: For zero setting key: To print the of the scale;...
  • Page 14: Function Settings

    FHB SERI size you selected and show the starting sample size on the display (you can now remove the samples if you want to return the scale to 0) 5. Press the [PCS] key to return to the weighing mode FUNCTION SETTINGS 1.
  • Page 15: When To Calibrate

    FHB SERI CALIBRATION When to calibrate Calibration may be required when it is initially installed, if the scale/balance is moved to a substantial distance. This is necessary because the weight of a mass in one location is not necessarily the same in another location. Also, with time and use, mechanical deviations may occur.
  • Page 16 FHB SERI the scale/balance is wet. Matter charged static electricity could influence the weighing. Discharge the static electricity. As example, the method is to use the electrification prevention spray, to spray it to both side of weighing platform. Hotline Call to our company TPS Corporation in Viet Nam Call Hotline (+84.8)62.888.666 / (+84.8) 62.999.111...