Rainier HYBRID DUAL FUEL R12000DF Manual

Rainier HYBRID DUAL FUEL R12000DF Manual

Open frame generator

Advertisement

R12000DF
Dual Fuel OPEN FRAME Generator
GASOLINE: 9500 Running Watts | 12000 Peak Watts
PROPANE: 8550 Running Watts | 10800 Peak Watts

Advertisement

Table of Contents
loading

Summary of Contents for Rainier HYBRID DUAL FUEL R12000DF

  • Page 1 R12000DF Dual Fuel OPEN FRAME Generator GASOLINE: 9500 Running Watts | 12000 Peak Watts PROPANE: 8550 Running Watts | 10800 Peak Watts...
  • Page 2: R12000Df Technical Specifications

    No part of this publication may be reproduced or used in any form by any means – graphic, electronic or mechanical, including photocopying, recording, taping or information storage and retrieval systems – without the written permission of Rainier Outdoor Power Equipment, LLC. DANGER This manual contains important instructions for operating this generator.
  • Page 3: Product Registration

    IMPORTANT: KEEP YOUR PURCHASE RECEIPT TO ENSURE TROUBLE-FREE WARRANTY COVERAGE. PRODUCT REGISTRATION To ensure trouble-free warranty coverage, it is important you register your Rainier generator. You can register your generator by either: 1. Filling in the product registration form below and mailing to:...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS R12000DF TECHNICAL SPECIFICATIONS ..2 MAINTENANCE ......19 PRODUCT REGISTRATION .
  • Page 5: Safety

    SAFETY SAFETY DEFINITIONS SAFETY SYMBOL DEFINITIONS The words DANGER, WARNING, CAUTION and NOTICE are used throughout this manual to highlight important information. Be certain that the meanings of these alerts are known to all who work on or near the equipment.
  • Page 6: General Safety Rules

    SAFETY GENERAL SAFETY RULES DANGER Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.
  • Page 7: Fuel Safety

    SAFETY FUEL SAFETY When transporting or servicing the generator: DANGER • Make certain the fuel shutoff valve is off and the fuel tank is empty. Gasoline and liquid petroleum gas • Make sure the LPG tank and LPG hose is not attached (LPG) are highly explosive and to the generator.
  • Page 8: Assembly

    ASSEMBLY INSTALLING WHEELS AND FEET INSTALLING WHEELS TO FRAME BEFORE ASSEMBLING THE 1. Insert axle pin through washer and wheel. GENERATOR, REVIEW THE SAFETY SECTION STARTING ON PAGE 5. CAUTION Never lift the generator without assistance. The generator is heavy and lifting without assistance could result in personal injury.
  • Page 9: Installing The Battery

    ASSEMBLY INSTALLING THE BATTERY 4. Pull back the black boot and securely attach the negative (-) battery cable (black boot) to the negative (-) WARNING battery post. Replace the black boot so it protects the cable lug and battery post. To avoid electric shock: •...
  • Page 10: Features

    FEATURES Fuel Selector Switch: Used to select and turn Oil Drain Plug: Must be removed to drain engine oil. on gasoline or propane fuel source. Propane Hook Up: Hook up your propane tank with Electric Start: Used to start the generator. the LPG hose provided to this inlet.
  • Page 11 FEATURES Fuel Gauge: Indicates gas level. Spark Plug Boot (Wire): Must be removed when servicing the engine or the spark plug. CARB Canister: Required for models sold into and used in California. Muffler and Spark Arrester: Avoid contact until engine is cooled down. Spark arrestor prevents sparks from exiting the muffler.
  • Page 12: Control Panel Features

    FEATURES CONTROL PANEL FEATURES AC BREAKER AC BREAKER ELECTRIC START VFT METE R 20 A 30 A OF F OF F 120/240V AC 50 A 120/240V AC 30 A L14-50 R MAIN BREAKE R L14-30 R STAR T 120V AC 30 A 120V AC 20 A 5-20R GFCI L5-30 R...
  • Page 13: Operation

    OPERATION BEFORE STARTING THE GENERATOR Weather – Never operate your generator outdoors during rain, snow or any combination of weather conditions that BEFORE STARTING THE GENERATOR, could lead to moisture collecting on, in or around the REVIEW SAFETY SECTION STARTING ON generator.
  • Page 14: Powercord

    Using Extension Cords Rainier Outdoor Power Equipment assumes no responsibility for the content within this table. The use of this table is the responsibility of the user only. This table is intended for reference only. The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and construction of cords are highly variable.
  • Page 15: Engine Fluids And Fuel

    OPERATION ADDING / CHECKING ENGINE ADDING GASOLINE TO THE FUEL TANK FLUIDS AND FUEL BEFORE ADDING GAS TO THE TANK PLEASE REVIEW FUEL SAFETY SECTION BEFORE ADDING/CHECKING ENGINE ON PAGE 7 FLUIDS AND FUEL, REVIEW SAFETY SECTION STARTING ON PAGE 5. WARNING DANGER Never refuel the generator while the engine is running.
  • Page 16: Connecting Lpg Tank

    OPERATION BEFORE STARTING THE GENERATOR CONNECTING THE LPG/PROPANE TANK BEFORE STARTING THE GENERATOR, BEFORE CONNECTING PROPANE TANK TO THE GENERATOR PLEASE REVIEW REVIEW SAFETY SECTION STARTING FUEL SAFETY SECTION ON PAGE 7 ON PAGE 5. Connecting LPG Tank Before attempting to start the generator, verify the following: 1.
  • Page 17: Starting The Generator

    OPERATION SWITCHING FUEL SOURCES FOR LPG/PROPANE: a. Make sure the LPG hose is safely secured from BEFORE ADDING GAS TO THE TANK the generator to the tank. PLEASE REVIEW FUEL SAFETY SECTION b. Turn the fuel selector knob to PROPANE. ON PAGE 7 c.
  • Page 18: Stopping The Generator

    OPERATION STOPPING THE GENERATOR Normal Operation During normal operation, use the following steps to stop your generator: 1. Remove any connected loads from the control panel receptacles. Fuel Shut Off - OFF 2. Allow the generator to run at “no load” to reduce and stabilize engine and alternator temperatures.
  • Page 19: Maintenance

    Spark Plug Check/Clean Replace Spark Arrestor Check/Clean *Service more frequently if operating in dry and dusty conditions TABLE 2: MAINTENANCE SCHEDULE - AUTHORIZED RAINIER SERVICE DEALER PERFORMED After First 20 After 50 Hours After 100 Hour Before Every Hours or First...
  • Page 20: Engine Oil Maintenance

    MAINTENANCE MAINTENANCE ENGINE OIL MAINTENANCE 6. Check oil level: When checking the engine oil, remove the oil fill plug/dipstick and wipe it clean. Engine Oil Specification Thread the oil fill plug/dipstick all the way back in and 1. Only use the engine oil specified in graphic below. then remove and check the oil level on the oil fill plug/ dipstick.
  • Page 21: Changing Engine Oil

    MAINTENANCE CHANGING ENGINE OIL AIR FILTER MAINTENANCE WARNING 1. Stop the engine. Never use gasoline or other flammable 2. Let engine sit and cool for several minutes (allow solvents to clean the air filter. Use only crankcase pressure to equalize). household detergent soap to clean the 3.
  • Page 22: Spark Plug Maintenance

    MAINTENANCE Cleaning the Air Filter - Continued NOTICE Never dispose of soap cleaning solution used to clean the air filter by dumping the solution into a sewer, on the ground, or into ground water or waterways. Always be environmentally responsible. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials.
  • Page 23: Checking And Adjusting Valve Lash

    MAINTENANCE CHECKING AND ADJUSTING VALVE LASH CLEANING THE GENERATOR It is important to inspect and clean the generator before CAUTION every use. Checking and adjusting valve lash Clean All Engine Air Inlet and Outlet Ports – Make must be done when the engine is cold. sure all engine air inlet and outlet ports are clean of any dirt and debris to ensure the engine does not run hot.
  • Page 24: Storage

    MAINTENANCE 5. With the fuel shut off valve open, start the engine 9. Replace the spark plug. and allow the generator to run until all the remaining 10. Move the generator to a clean, dry place for storage. gasoline in the fuel lines and carburetor is consumed and the engine shuts off.
  • Page 25 TROUBLESHOOTING 1. Fuel shutoff valve is in the OFF position. 1. Move the fuel shut off valve to the ON position. 2. Generator is out of gasoline. 2. Add gasoline to the generator. 3. Fuel flow is obstructed. 3. Inspect and clean fuel delivery passages. 4.
  • Page 26 RAINIER OUTDOOR POWER EQUIPMENT’S RESPONSIBILITY Rainier Outdoor Power Equipment warrants to the original purchaser that its Rainier line of generators will be free from defects in material and workmanship. Under normal use and maintenance from the date of purchase, Rainier Outdoor Power Equipment agrees to repair or replace at Rainier Outdoor Power Equipment’s discretion, any defective product free of charge at any authorized Rainier Outdoor Power...
  • Page 27 There are no warranties extended other than as provided herein. This limited warranty may be modified only by Rainier Outdoor Power Equipment. Any implied warranties allowed by law shall be limited in duration to the terms of the express warranty provided herein.
  • Page 28 RainierPower.com Version 07.06.18KD Rev2 28 |...

Table of Contents