TDR
A wire connected to a suitable ground can be connected to the ground binding post
on the TriTone Transceiver in place of the ground cord if needed. This can be used
when the best ground is some distance from the testing point. Using the shortest
ground possible improves meter measurements.
*The Ground clip is not required if T
3

OPERATION

The following information describes the operation of the controls on the TriTone
Transceiver.
3.1

POWER

The [PWR/CLR] key used to turn the unit on and off.
Press and hold the key for 1 to 2 seconds to turn the unit on.
Press and hold the key for approximately 3 seconds to turn the unit off.
The [PWR/CLR] key is also used to terminate any function and return to
the main menu.
3.2

BATTERY LEVEL

A battery level indicator is displayed in the top, left corner of the display. The
batteries are rechargeable by plugging the supplied charger into the connector on
the top of the unit. When only one bar is shown in the battery level indicator, the
unit should be charged as soon as practical.
The unit may be used while power is supplied to the charge connector if an external
power source is available; however, the power supply should not be used when
using the AC noise meter function.
3.3

CONFIGURATION - SYSTEM

3.3.1

BACKLIGHT

The display backlight can be adjusted for various light conditions. Note that lower
backlight settings will extend the battery duration.
Allied Analogic, Inc.
Black clip to Tip wire, Red clip to Ring wire,
and Ground clip to shield/ground
Green Ground clip to Tip wire and Red Clip
to Ring wire
Black clip to Tip wire, Red clip to Ring wire,
and Ground clip to shield/ground
Black clip to Tip wire and Red clip to Ring
wire
G or R
G measurements are not needed.
4
*
Copyright © 2019