1. Introduction RODUCT VERVIEW The ProPlex Opto-Splitter is range is designed for standard DMX-512 signal amplification, regeneration, and splitting to multiple outputs. Just a few of the features include: • Full RDM functionality. RDM defeat switch on each input (Opto-Splitter 2x8 and Mini non-RDM excluded).
• Never disconnect power cord by pulling or tugging on the cord. Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your distributor.
RDM / DMX S ERIAL 1. Connect the male 5-pin connector of the DMX cable to the female output 5-pin connector of the lighting console. 2. Connect the end of the cable coming from the lighting console which will have a female 5-pin connector to the input connector of the DMX Splitter consisting of a male 5-pin connector.
INPUT OUTPUT CONNECTIONS DMX splitter outputs can be manually switched to each of the two inputs. Following are a few examples. Example 1: RDM/DMX Splitter input /output connection scheme 10+0: One of the DMX inputs is connected to all of DMX outputs, but a second DMX input is not used, i.e. not connect to any of the DMX outputs. Using Input A: Using Input B: Example 2: RDM/DMX Splitter input /output connection scheme 4+4...
2. Operation (RDM) PERATING ODES The Opto-Splitter 2x8 RDM and 2x10 RDM have two modes: DMX, and DMX with RDM. Modes can be switched using the toggle switch located on the front panel. Note – The Opto-Splitter Mini RDM always has RDM enabled. Switch is set to DMX Switch is set to DMX with RDM SSIGNING...
LED I NDICATORS MODEL DEPENDENT LED I RONT PANEL NDICATORS DATA – DMX input signal LED indicators are located on left side of the front panel and indicate whether the DMX signal is received at the input. DMX input signal LED indicators have two modes: •...
LED I EAR PANEL NDICATORS Terminator – The Terminator LED indicators signal whether the built-in DMX terminator is switched on or off. There are two positions: • On: Terminator is activated. • Off: Terminator is deactivated. Activate the DMX terminator if you want to stop data reflections. Note: Only available on Opto-Splitter 2x10 RDM.
(2) years from the date of original sale by TMB. TMB’s warranty shall be restricted to the repair or replacement of any part that proves to be defective and for which a claim is submitted to TMB before the expiration of the applicable warranty periods.
Need help?
Do you have a question about the ProPlex Opto-Splitter Series and is the answer not in the manual?
Questions and answers