Von Duprin RX S1 Installation Instructions

Switch retrofit kit

Advertisement

Quick Links

VON DUPRIN
 This kit includes the following parts:
{
RX
{
RX-LC
8-18 X 3/8" Flat Head Screw (2)
Step 
Disassemble the device. (Remove from door if mounted.)
22 Device
941038_00(4) Copyright © 2003 Ingersoll-Rand. All rights reserved.

INSTALLATION INSTRUCTIONS

®
RX/RX-LC/S1 Switch Retrofit Kit
This switch is intended for signaling purposes only and is rated for a
.1 ampere to 3 ampere resistive load at 24VDC/AC. Use with inductive
or capacitive loads (magnetic locks or solenoid devices) derates the
capacity of the switch. Consult the factory for assistance.
This switch is intended for systems using low current signals. The switch is
rated for a maximum of 50mA. Consult the factory for assistance.
Switch Assembly
Remove push bar.
Base Plate
Assembly
 Remove screws.
Standard (RX)
or low current (RX-LC)
Cable Tie 1.5"
Dogging assembly may not
be present on all devices.
Nylon Fastener
Remove mechanism case.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RX S1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Von Duprin RX S1

  • Page 1: Installation Instructions

    VON DUPRIN INSTALLATION INSTRUCTIONS ® RX/RX-LC/S1 Switch Retrofit Kit  This kit includes the following parts: This switch is intended for signaling purposes only and is rated for a .1 ampere to 3 ampere resistive load at 24VDC/AC. Use with inductive or capacitive loads (magnetic locks or solenoid devices) derates the capacity of the switch. Consult the factory for assistance. This switch is intended for systems using low current signals. The switch is RX-LC rated for a maximum of 50mA. Consult the factory for assistance. Standard (RX) or low current (RX-LC) Switch Assembly Nylon Fastener 8-18 X 3/8" Flat Head Screw (2) Cable Tie 1.5" Step  Disassemble the device. (Remove from door if mounted.) 22 Device Remove push bar. Dogging assembly may not be present on all devices. Remove mechanism case. Base Plate Assembly  Remove screws. 941038_00(4) Copyright © 2003 Ingersoll-Rand. All rights reserved.
  • Page 2 33/35 Device If the push bar has 2 screws for end cap, replace with the 2 screws provided in this kit.  Remove push bar. Dogging assembly may not be present on all devices. Remove mechanism case. Base Plate Assembly 33A/35A & 98/99 Device If the push bar has 2 screws for end cap, replace with the Remove. 2 screws provided in this kit. Remove push bar. This end only Dogging assembly may not be present on all devices. 98/99 device center case shown Used on 33A/35A device only Remove mechanism case. Base Plate Assembly Page 2...
  • Page 3 Step  Remove & discard this bearing strip before snapping switch assembly onto rear guide base. 1 3/8" 1 7/8" Step  Drill two1/8" holes through rear Rear Guide Base guide base only if holes are not present. Step  Install Switch Assembly. Step  Install nylon fastener. Cable tie Step  Route the wires from the switch assembly through this hole. Wires are not to interfere with any moving parts. Secure wires with a cable tie. Page 3...
  • Page 4 Step Check the switch for proper actuation. Depress the bellcrank, the Release the bellcrank, the switch should actuate switch should actuate during this movement during this movement If adjustment is needed, loosen screw in the side of the switch assembly and slide switch forward RX actuator position or backward as necessary. Switch Switch Yellow Yellow *Red or Green *Red or Green Blue Blue *Red = 3A Green = 50mA Step  Prep door for device wiring. End Cap Mounting Bracket Drill 5/16" - 5/8" hole in the door this side only using the end cap mounting  bracket for location. Connect wires to power transfer, electric hinge, etc. Refer to product instructions. Note: Hole is not necessary for an alarm kit, refer to its installation Page 4...