Summary of Contents for Airssential Home LifeTemp Radient AI-RADTH
Page 1
LifeTemp Radient ® ® Non-Contact Thermometer Instruction Manual Read this manual carefully before use to understand all operational and safety information. This manual contains important information for the safe and effective use of the Airssential LifeTemp Radient Non-Contact Thermometer. Keep this manual in a safe place for future reference.
Introduction Congratulations on the purchase of your new Airssential LifeTemp Radient Non-Contact Thermometer. This device is a precision instrument that hygienically and accurately records temperature in a safe and non-invasive manner. The LifeTemp Radient thermometer integrates advanced technology and ergonomic design to produce an efficient device for temperature monitoring that eliminates the inconvenience associated with other thermometry methods and easily addresses the issue of disobliging patients whether they be infants or adults.
LifeTemp Radient Thermometer Components & Accessories Unpacking Your LifeTemp Radient Thermometer Remove the thermometer from the carton and carefully examine the contents (Radient Thermometer, User manual and two AAA batteries) to ensure all listed items are in the carton and undamaged. Report anything missing or damaged to the point of purchase. Retain carton and packing materials for use in shipping or storing the thermometer.
Thermometer Functions The functions of the thermometer’s essential parts are described in Figure 2. Button Function(s) Switching the device on / starting temperature measurement Setting the accoustic signal (On/Off) Setting the measurement method Displaying stored measurements (max 32) Setting the measurement units (°C/°F) Display Meaning In body temperature mode...
Preparing for First Use Before using this thermometer, please follow the instructions below to insert the supplied batteries and adjust the device’s settings to your requirements. Installing Batteries To install fresh batteries in this thermometer: 1. Open the battery compartment on the back of the thermometer, by sliding down the battery compartment lid, as shown in Figure 3.
Setting the Measurement Completion Sound To silence the measurement completion sound (the beep), press the Sound button when the thermometer is on. Each time the sound button is pressed, the measurement completion sound will be switched on or off. After pressing the Sound button, if the LCD screen displays the symbol, the thermometer will emit the measurement completion sound.
Page 8
If there is perspiration on the forehead wipe the area dry before taking a temperature measurement. Do not take temperature readings on areas where scars or skin disorders (eczema, dermatitis, etc) are evident. During temperatures measurement it is important that patients remain still. Movement during the measurement procedure can result in an inaccurate reading.
Normal Body Temperature Normal body temperature is unique to each individual and varies within an individual range. The normal ranges for temperature measurements, taken from the ear canal, vary with age as follows: 0 to 2 years ......36.4°C to 38.0°C 3 to 10 years ....36.1°C to 37.8°C 11 to 65 years ....35.9°C to 37.6°C Over 65 years ....35.8°C to 37.5°C...
Recalling Stored Measurements This thermometer can store 32 readings in memory. To recall temperature values from memory briefly press the button to activate the device. Now press the button and the last measurement is displayed. See Figure 8. Each FIgURE 8 additional press of the button recalls the next most recent measurement.
Cleaning and Storage The most delicate part of this thermometer is the probe sensor (refer to Figure 1) which must be kept clean and undamaged to ensure accuracy. Do not touch the probe sensor with your fingers. 1. To clean the probe’s sensor or the thermometer’s exterior, use a gauze swab, moistened with water and alcohol and carefully wipe the casing or probe area.
Device Certifications The LifeTemp Radient Thermometer is a Class IIa Medical Device. In compliance 0120 with the European standard, this device bears the CE conformity mark of the Medical Devices Directive and complies with the following reference standards: IS0 13485 2003 Medical devices - Quality management system –...
Warranty and Service The LifeTemp Radient Non-Contact Thermometer is covered by a warranty offered by Airssential Home Health Care Solutions (“Airssential”), a division of Boian Surgical Pty Ltd., to the original purchaser of the product. Proof of purchase is required to substantiate warranty claims.
Technical Specifications Power: 3V DC (Two AAA (LR03) Battery 1.5V) Measurement Method: Infrared (IR) Non-Contact Measurement Button Functions: Switch for body or object temperature Switch for preferred temperature scale (°C or °F) Switch for optional on/off Sound control Memory recall Operating Conditions: Temperature: 16°C to 40°C (60.8°F to 104°F) Humidity: <...
Symbols Used In This Manual Caution - Consult Instructions for Use Type B applied part Battery Recycling/Environment Protection Manufacturer Please read the instructions for use Temperature Limitation Appendix 1 Guidance and Manufacturer’s Declaration – Electromagnetic Emissions The thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the thermometer should assure that it is used in such an environment.
Page 16
Immunity Test IEC 60601 Test Compliance Electromagnetic Environment – Level Level Guidance Conducted RF 3 Vrms Portable and mobile RF IEC 61000-4-6 150 kHz to 80 applicable communications equipment should be used no closer to any Radiated RF part of this thermometer, including IEC 61000-4-3 3 V/m 3 V/m...
Page 17
Immunity Test IEC 60601 Test Compliance Electromagnetic Environment – Level Level Guidance Electrostatic 6 kV contact 6 kV Floors should be wood, concrete discharge (ESD) 8 kV air contact or ceramic tile. If floors are covered IEC 61000-4-2 8 kV air with synthetic material, the relative humidity should be at least 30 %.
Appendix 2 Recommended separation distances between portable and mobile RF communications equipment and the ME EQUIPMENT or ME SYSTEM The thermometer is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the thermometer can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the thermometer as recommended below, according to the maximum output power of the communications equipment.
Page 20
Airssential Home Health Care Solutions 122 Gow Street, Padstow NSW 2211 Phone (02) 9708 5560 Airssential Home Health Care Solutions is a division of Boian Surgical Pty Ltd. ® Airssential , LifeTemp and Radient are the registered trademarks of Boian Surgical Pty Ltd.
Need help?
Do you have a question about the LifeTemp Radient AI-RADTH and is the answer not in the manual?
Questions and answers
Can't open battery cover stuck fast Advice please