Immergas MAGIS PRO ERP Instruction And Recommendation Booklet page 25

Mono-phase hydronic module to pair with an outdoor condensing unit
Table of Contents

Advertisement

Id
Parameter
Parameter
Establishes the unit ignition and switch-off mode in DHW mode.
T 02
DHW thermostat
It is enabled when the water in the storage tank goes below the DHW set
value and is disabled when the temperature exceeds the DHW set value.
Central heating
The hydronic module has an electronic timer, which prevents the genera-
T 05
ignitions timer
tor from igniting too often in central heating mode
The system is set to switch on immediately after a request for room heating/
Delay request
T 07
air conditioning. For special systems (e.g. zone systems with motorised valves,
from TA
etc.), it may be necessary to delay ignition.
Establishes the display lighting mode.
AU: the display lights up during use and lowers after 15 seconds of inactivity.
T 08
Display lighting
OFF: the display lighting is always off.
ON: the display lighting is always on.
Establishes what the indicator displays 14 (Fig. 2-1).
"Summer" mode:
ON: circulator active, displays the flow temperature
OFF: the indicator is always off
T 09
Display
"Winter" and "cooling" mode:
ON: circulator active, displays the flow temperature
OFF: always displays the value set on the central heating selector
Description
In the event of an anomaly, the display flashes.
pump off the indicator is off
circulator off, displays the value set on the central heating selector.
25
Customised
Range
Default
value
0 ÷ 20 °C
4
0 - 10 min-
3
utes
0 - 240
seconds
0
(step 10 sec)
AU - OFF
AU
- ON
ON - OFF
ON