Using Dmx512 Controller - Focon Showtechnic EXPOLITE LED Profile 750 HD User Manual

Table of Contents

Advertisement

Available languages

Available languages

SLOCK: Settings Lock. In this menu is set whether the menu SETTING is only accesable after
entering the password (ON) or without a password (OFF). Default password is UP - DOWN - UP -
DOWN - ENTER.
DMX ERROR: sets how the fixture responses if DMX-signal gets lost. Set SAVE to hold the last
received value or BLACK for blackout.
RESET: sets all editable settings back to factory default.
MODE SETTING: sets if the fixture is a master and sends data to other fixtures (MAST), or not
(SELF).
PWM: gives the user the possibility to adjust the PWM-frequency of the leds (600Hz/1200Hz/2000Hz/
4000Hz/25000Hz).
Current Software Version
When the software of the fixture is booting, the current installed software version is shown for about 5
seconds in the display.
Using DMX512 Control
DMX-Channel assignment
This device has several DMX personalities. In each personality a different number of DMX channels
is used and the reaction of the device differs accordingly. There are three DMX personalities with 1, 2
and 3 channels selectable.
Because of changes in the firmware of the fixture, functions can be added or changed.
You can find the current version „DMX-Channels" as PDF-file on the website, ready to download.
UNO
1
0-255
DOS
1
0-255
2
0-255
STD.P
1
0-255
2
0-255
0-9
10-99
3
100-109
110-179
180-189
190-255
Master Dimmer
Master Dimmer
Master Dimmer Fine
Master Dimmer
Master Dimmer Fine
Strobe
No Function
Strobe (Slow to fast)
No Function
Lightning Strobe
No Function
Random Strobe
E-19