Requirement - Toshiba TCB-AX21UL Installation Manual

Remote controller for air conditioner (split type)
Hide thumbs Also See for TCB-AX21UL:
Table of Contents

Advertisement

Wireless remote controller kit
6

REQUIREMENT

The control by two remote controllers is enabled by installing the wireless remote controller
with the wired remote controller for an indoor unit.
(Max. 2 remote controllers of wireless or wired are insatiable.)
"2-remote controllers" controlling means that one or multiple units are operated by the
multiple remote controllers.
NOTE
1. Upon confirmation of the terminal numbers of the indoor unit, connect the remote
controller cables without miscabling. (If applied AC 208/230 Volt, damage the unit.)
2. The multiple wireless remote controller kits cannot concurrently be used for an indoor
unit.
3. When installing simultaneously the wireless remote controller with the wired remote
controller, set one of them as the sub remote controller.
• When setting the wired remote controller as the sub, exchange the address connector
at the rear of P.C. board of wired remote controller from master to sub remote
controller.
• When setting the wireless remote controller as the sub, turn the switch of wireless
remote controller Signal receiving unit from RCU: MAIN to RCU:SUB.
To operate an indoor unit by 2 remote controllers
The indoor unit is operated if either wireless or wired remote controller is set as MAIN or SUB
remote controller.
(Total cable length: Within 1312'4" (400 m))
Signal receiving unit
9-EN
Wireless remote
controller kit
Terminal block for
remote controller
cable
Earth
Wired remote
controller (SUB)
(Sold separately)
Remote controller cable
(Procured locally)
(AWG20 (0.5 mm
(UL wires rated 300 V)
Indoor unit
– 9 –
Installation Manual
2
))

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wx-ta01ues

Table of Contents