2-L. Test tlode of Display Microcomputer (tC401)
Connect Pin @ of IC40l to ground and tum ON the pOWER
switch, thus you can test the following 3 tests.
(f)Nl FL tube ON
This mode is acruared immediately afrer ruming ON the pOWER
switch.
(2)FL tubc scgment check
This mode is actuared by pressing the @ key in the state of (l).
Every time the @ key is pressed, the-segmenæ are indicated
scquentially from the segment a. When the last I segment is
displayd keying in is no longer accepted while continuing the
lighting-up state of the last segment. Conditions are normal
provided all lamps lighr up in the following order.
(3)KEY check
This mode is effected by pressing the@ key in the state of (l),
while indicating "l." Every time a new key is presscd subse-
quently, the indicated number is incremented. Conditions arc
normal provided "7" is indicated when all types of keys are
prcssed. Even if a key is prcssed again, it is not counted.
. To leave the mode (2) or (3), press the@andfifl keys in
duplication, thercby the mode rerurning to all ON mode.
3G
i
(o
sEcTroN 2
TEST MODES
2-2.
Test tlodes of CD System Controiler (tC2O2l
(I)ADJUSTmode
When this mode is effected, the machine is operated normalty
except for the following.
. when pin {D, IC20l (ADJ) is ser ro ..L" after rurning oN the
POWER swirch:
I . GFS is no longer monitored during PLAY, PAUSE or SEARCH,
while not sropping even with GFS rcmaining srill ar. L" (NG).
2. No high-speed feeding is activated during SEARCH.
3. Focus gain is reset to normal gain during PLAY (normally, the
gain is lowered to reduce noise when FOCUS is locked).
. When Pin @, IC20t (AFADJ) is set ro..L" after tuming ON the
FOWER switch:
l. Regardless of Pin @ (ADJ) of the CLV-S fixed function, the CLV
mode during PLAY becomes CLV-S (rough servo) only while
Pin e remains "L".
(2)AFADJUST mode
In this mode, it is possible to check the interface between the
display micon (IC4OI) and CD syscon (IC20l).
. Set Pin @, IC20l (AFADJ) ro "L" before rurning ON rhe FOIryER
switch.
l. Every time the @key is pressed after turning On the pOWER
switch, indication on the FL tube is switched conespondingly.
Conditions are normal provided the indication rcpeats the 4
patterns including all lamp ON.
T[mON the FOIITER
after connectins
Pin@.rc4or 6cNp.
All FL tube
lamps ON mode
Duplicated pressing of El and[fl
r . 7 1 8 1 9 2 0