Sony CyberShot DSC-P72 Service Manual page 30

Hide thumbs Also See for CyberShot DSC-P72:
Table of Contents

Advertisement

DSC-P72
1-2-3.
Initializing the 6F Page Data
1. Initializing the 6F Page Data
Note: If the 6F page data has been initialized, the following adjustments
need to be performed again.
1) Camera system adjustments
Adjusting page
Adjusting Address
Initializing Method:
1) Select page: 00, address: 01, and set data: 01.
2)
Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
3)
Click [Page] to display the INPUT PAGE screen, and input
"6F".
4)
Click [Preset Data Read] on the SEUS PAGE EDIT screen to
display the INPUT SETID screen.
5)
Input "02" and click [OK] to read the preset data.
6)
On the SEUS PAGE EDIT screen, change the data of the "Fixed
data-2" address shown in the following table by manual input.
Note: New data for changing are not shown in the table because they
are different in destination. When changing the data, copy the
data built in the same model. If copy the data built in the different
model, the camera may not operate.
7) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
8)
Click [Write] to write the initializing data to the EEPROM of
the camera.
9)
Click [Close] to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing of 6F Page data
Order Page Address Data
1
20
00
2
20
01
3
4
5
6F
00 to FF
Procedure
29
Write the data.
29
Write the data.
Check "Receive Paket Error" is
displayed on the SEUS screen.
Turn on the power.
Click [Connect] on the SEUS
screen.
2. 6F Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. Initializing the 6F
Page Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of 6F
Page Data".)
Address
Address
Initial value
Initial value
10 to 13
10
FF
11
FF
12
FF
13
FF
14
FF
15
FF
16
FF
17
FF
18
36
19
54
1A
87
1B
71
1C
10
1D
C0
1E
00
1F
00
20
00
21
00
22
00
23
00
24
20
25
20
26
13
27
46
28
0A
29
00
2A
00
2B
00
2C
00
2D
00
2E
00
2F
00
30
00
31
00
32
00
33
00
34
00
35
00
36
00
37
00
38
00
39
00
3A
00
3B
00
3C
00
3D
00
3E
FF
3F
40
00
41
00
6-10
Remark
Remark
Fixed data-1
Auto focus illumination check
Flange back Adj.